Sir, Most drugs used in the operation theatres are packaged in glass ampoules as they ensure clear visibility of the drugs, no reaction with medications and the ability to vacuum seal.[1] However, use of the glass ampoules has its own inherent risks. The glass ampoules require to be broken before loading the drugs into syringes. It is a common practice to don the gloves and break the ampoules to protect one’s hands. However, it has been our observation that occasionally, a few broken shards of glass may remain stuck to the gloves, imposing a potential threat to patient’s safety during subsequent handling of the patient, especially during airway management. Glass particles may also be injected into the body by intramuscular and intravenous routes, which have been reported to be dangerous or harmful to the patients.[23] Apart from severe inflammatory response, injected glass particles can cause systemic effects like embolism, tissue necrosis, sepsis and end-organ damage.[34] Other than glass particles, incidences of iatrogenic foreign bodies that endangered the airway, such as plastic sleeve of a stylet and a metal rivet from the McCoy laryngoscope, have also been documented.[56] One such incidence was brought to our notice recently where an anaesthesiology resident after loading the neuromuscular reversal drugs immediately proceeded for tracheal extubation of the patient. However, the tiny glass shards clinging to his gloves caught our attention [Figure 1]. The anaesthesiologist was asked to discard his gloves and don the new ones.
Figure 1

Fragmented glass particle stuck into surgical gloves

Fragmented glass particle stuck into surgical gloves This incidence brings to light the potential risk this practice might carry. The shards may accidentally be introduced into the oral cavity of the patient during airway management. This might cause unnecessary discomfort or pain to the patient, the reason for which might remain obscure to us. There could be an inadvertent injury to the eyes as well, while taping or untaping them. Through this correspondence, we emphasise on using a designated ampoule cutter that produces minimal or no fragments, compared to breaking a glass ampoule with hand. Also, glass ampoules should be broken away from the patient, anaesthesia workstation and the intubation area. Since the shards of glass resulting from breaking of ampoules are frequently tiny and transparent, they might escape observation if they stick on to the gloves. Therefore, for the safety of the patient, the best preventive measure to avoid any such inadvertent harm is to ideally discard the gloves after breaking open glass ampoules. However, usage of new gloves each time can be a costly affair, especially in a developing country. Thus, we recommend very close observation of the gloves each time after breaking a glass ampoule and before handling the patient.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  6 in total

1.  Glass particle contamination: is it here to stay?

Authors:  S T Lye; N C Hwang
Journal:  Anaesthesia       Date:  2003-01       Impact factor: 6.955

2.  Glass contamination in parenterally administered medication.

Authors:  Stan T Preston; Kathleen Hegadoren
Journal:  J Adv Nurs       Date:  2004-11       Impact factor: 3.187

3.  A strategy for reducing particulate contamination on opening glass ampoules and development of evaluation methods for its application.

Authors:  Kyeong-Ryoon Lee; Yoon-Jee Chae; Sung-Eel Cho; Suk-Jae Chung
Journal:  Drug Dev Ind Pharm       Date:  2011-06-27       Impact factor: 3.225

4.  The effect of different methods of intravenous injection on glass particle contamination from ampules.

Authors:  Ga Eul Joo; Kyeong-Yae Sohng; Michael Yong Park
Journal:  Springerplus       Date:  2016-01-06

5.  Rare iatrogenic airway foreign body: The rivet from the fulcrum of the McCoy laryngoscope blade.

Authors:  Alpna Jain; Manish Naithani; Zainab Chaudhary; Pankaj Sharma
Journal:  Indian J Anaesth       Date:  2012-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.