Delta Increment in Pacing QRS Duration Predicts Cardiovascular Mortality in Patients with Pre-Existing Bundle Branch Block Receiving Permanent Pacemakers.

Huang-Chung Chen1, Wen-Hao Liu1, Chien-Hao Tseng1, Yung-Lung Chen1, Wei-Chieh Lee1, Yen-Nan Fang1, Shaur-Zheng Chong1, Mien-Cheng Chen1.   

Abstract

Background: The clinical implication of pre-existing intraventricular conduction disturbance (IVCD) in permanent pacemaker (PPM) recipients is unknown.
Objectives: To explore the clinical outcomes in patients with pre-existing IVCD after implantation of PPMs.
Methods: A total of 1424 patients who received PPMs were categorized into three groups by pre-procedural electrocardiography: patients without IVCD (n = 1045), patients with right bundle branch block (RBBB) (n = 309), and patients with left bundle branch block (LBBB) (n = 70). The primary outcome was cardiovascular (CV) mortality. Receiver operating characteristic curve analysis was performed to determine the optimal cut-off values of variable in predicting CV mortality.
Results: During follow-up, there was no significant difference in CV mortality between patients with and without IVCD. In multivariate analysis, independent predictors of CV mortality were age [hazard ratio (HR): 1.03; 95% confidence interval (95% CI): 1.00-1.05; p = 0.026], history of heart failure [HR: 1.98; 95% CI: 1.19-3.29; p = 0.009], chronic kidney disease [HR: 1.75; 95% CI: 1.11-2.74; p = 0.015] and increment in pacing QRS duration [HR: 1.01; 95% CI: 1.00-1.04; p = 0.038]. Delta increments in pacing QRS duration ≥ 43 msec [HR: 2.91; 95% CI: 1.23-6.83; p = 0.014] in patients with pre-existing RBBB, and ≥ 33 msec [HR: 11.44; 95% CI: 2.03-64.30; p = 0.006] in patients with pre-existing LBBB were independent determinants of CV mortality. Conclusions: There was no difference in CV mortality between patients with or without IVCD. However, wider pacing QRS duration increased the risk of CV mortality in PPM recipients, and delta increment in pacing QRS duration increased the risk of CV mortality in patients with pre-existing IVCD.

Entities:  

Keywords:  Cardiovascular mortality; Delta QRS duration; Permanent pacemaker; Pre-existing bundle branch block

Year:  2022        PMID: 35873129      PMCID: PMC9295034          DOI: 10.6515/ACS.202207_38(4).20220115A

Source DB:  PubMed          Journal:  Acta Cardiol Sin        ISSN: 1011-6842            Impact factor:   1.800


  20 in total

Review 1.  Significance of QRS complex duration in patients with heart failure.

Authors:  Amir Kashani; S Serge Barold
Journal:  J Am Coll Cardiol       Date:  2005-12-20       Impact factor: 24.094

2.  Clinical implications of electrocardiographic bundle branch block in primary care.

Authors:  Peter Vibe Rasmussen; Morten Wagner Skov; Jonas Ghouse; Adrian Pietersen; Steen Møller Hansen; Christian Torp-Pedersen; Lars Køber; Stig Haunsø; Morten Salling Olesen; Jesper Hastrup Svendsen; Jacob Melgaard; Claus Graff; Anders Gaardsdal Holst; Jonas Bille Nielsen
Journal:  Heart       Date:  2019-05-25       Impact factor: 5.994

3.  Clinical Outcomes of His Bundle Pacing Compared to Right Ventricular Pacing.

Authors:  Mohamed Abdelrahman; Faiz A Subzposh; Dominik Beer; Brendan Durr; Angela Naperkowski; Haiyan Sun; Jess W Oren; Gopi Dandamudi; Pugazhendhi Vijayaraman
Journal:  J Am Coll Cardiol       Date:  2018-03-10       Impact factor: 24.094

4.  Outcomes With Left Bundle Branch Block and Mildly to Moderately Reduced Left Ventricular Function.

Authors:  Chance M Witt; Gang Wu; Dachun Yang; David O Hodge; Veronique L Roger; Yong-Mei Cha
Journal:  JACC Heart Fail       Date:  2016-09-07       Impact factor: 12.035

5.  Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.

Authors:  Bruce L Wilkoff; James R Cook; Andrew E Epstein; H Leon Greene; Alfred P Hallstrom; Henry Hsia; Steven P Kutalek; Arjun Sharma
Journal:  JAMA       Date:  2002-12-25       Impact factor: 56.272

6.  QRS Duration Is a Predictor of Adverse Outcomes in Heart Failure With Preserved Ejection Fraction.

Authors:  Jacob Joseph; Brian C Claggett; Inder S Anand; Jerome L Fleg; Thao Huynh; Akshay S Desai; Scott D Solomon; Eileen O'Meara; Sonja Mckinlay; Bertram Pitt; Marc A Pfeffer; Eldrin F Lewis
Journal:  JACC Heart Fail       Date:  2016-03-30       Impact factor: 12.035

7.  Major determinant of the occurrence of pacing-induced cardiomyopathy in complete atrioventricular block: a multicentre, retrospective analysis over a 15-year period in South Korea.

Authors:  Jun Hyung Kim; Ki-Woon Kang; Jung Yeon Chin; Tae-Seok Kim; Jae-Hyeong Park; Yu Jeong Choi
Journal:  BMJ Open       Date:  2018-02-08       Impact factor: 2.692

8.  Post-pacemaker implant QRS duration and heart failure admission in patients with sick sinus syndrome and complete atrioventricular block.

Authors:  Wei-Chieh Lee; Hsiu-Yu Fang; Huang-Chung Chen; Yung-Lung Chen; Tzu-Hsien Tsai; Kuo-Li Pan; Yu-Sheng Lin; Mien-Cheng Chen
Journal:  ESC Heart Fail       Date:  2019-05-20

9.  Effectiveness of Ventricular Intrinsic Preference (VIP™) and Ventricular AutoCapture (VAC) algorithms in pacemaker patients: Results of the validate study.

Authors:  Rakesh Yadav; Aparna Jaswal; Sridevi Chennapragada; Prakash Kamath; Shirish M S Hiremath; Dhiman Kahali; Sumit Anand; Naresh K Sood; Anil Mishra; Jitendra S Makkar; Upendra Kaul
Journal:  J Arrhythm       Date:  2015-10-01
View more