| Literature DB >> 35859000 |
Abdullah Alturki1, Ayman Al-Eyadhy2, Ali Alfayez3, Abdulrahman Bendahmash4, Fahad Aljofan4, Fawaz Alanzi4, Hadeel Alsubaie4, Moath Alabdulsalam4, Tareq Alayed4, Tariq Alofisan4, Afnan Alnajem5.
Abstract
This study aimed to assess the potential impact of implementing an electronic alert system (EAS) for systemic inflammatory syndrome (SIRS) and sepsis in pediatric patients mortality. This retrospective study had a pre and post design. We enrolled patients aged ≤ 14 years who were diagnosed with sepsis/severe sepsis upon admission to the pediatric intensive care unit (PICU) of our tertiary hospital from January 2014 to December 2018. We implemented an EAS for the patients with SIRS/sepsis. The patients who met the inclusion criteria pre-EAS implementation comprised the control group, and the group post-EAS implementation was the experimental group. Mortality was the primary outcome, while length of stay (LOS) and mechanical ventilation in the first hour were the secondary outcomes. Of the 308 enrolled patients, 147 were in the pre-EAS group and 161 in the post-EAS group. In terms of mortality, 44 patients in the pre-EAS group and 28 in the post-EAS group died (p 0.011). The average LOS in the PICU was 7.9 days for the pre-EAS group and 6.8 days for the post-EAS group (p 0.442). Considering the EAS initiation time as the "zero time", early recognition of SIRS and sepsis via the EAS led to faster treatment interventions in post-EAS group, which included fluid boluses with median (25th, 75th percentile) time of 107 (37, 218) min vs. 30 (11,112) min, p < 0.001) and time to initiate antimicrobial therapy median (25th, 75th percentile) of 170.5 (66,320) min vs. 131 (53,279) min, p 0.042). The difference in mechanical ventilation in the first hour of admission was not significant between the groups (25.17% vs. 24.22%, p 0.895). The implementation of the EAS resulted in a statistically significant reduction in the mortality rate among the patients admitted to the PICU in our study. An EAS can play an important role in saving lives and subsequent reduction in healthcare costs. Further enhancement of systematic screening is therefore highly recommended to improve the prognosis of pediatric SIRS and sepsis. The implementation of the EAS, warrants further validation in multicenter or national studies.Entities:
Mesh:
Year: 2022 PMID: 35859000 PMCID: PMC9300636 DOI: 10.1038/s41598-022-16632-2
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.996
Baseline demographic and clinical characteristics for the pre- and post-EAS groups.
| Variables | Pre-EAS group n = 147 | Post-EAS group n = 161 | |
|---|---|---|---|
| 0.36* | |||
| Male | 80 (54.42) | 96 (59.63) | |
| Female | 67 (45.58) | 65 (40.37) | |
| Age median (25th, 75th percentile) (years) | 4.30(1.87,11.44) | 5.56(0.79,10.68) | 0.149M |
| 0–2 | 53 (36.05) | 44 (27.33) | |
| 2–7 | 39 (26.53) | 32 (19.88) | 0.0626* |
| 8–12 | 35 (23.80) | 54 (33.54) | |
| > 12 | 20 (13.60) | 31 (19.25) | |
| Weight mean ± SD (kg) | 17.21 ± 11.98 | 17.14 ± 13.2 | 0.962t |
| Hematology/oncology | 48 (32.65) | 54 (33.54) | |
| Bone marrow transplant | 30 (20.40) | 41 (25.57) | |
| Immunodeficiency | 11 (7.48) | 2 (1.24) | |
| Genetic/metabolic | 9 (6.12) | 12 (7.45) | |
| Cardiac | 24 (16.33) | 11 (6.83) | 0.0348* |
| Gastroenterology/hepatology | 2 (1.36) | 8 (4.97) | |
| Neurology | 7 (4.76) | 8 (4.97) | |
| Solid organ transplant | 11 (7.48) | 13 (8.07) | |
| Renal | 2 (1.36) | 6 (3.73) | |
| Endocrinology | 2 (1.36) | 4 (2.24) | |
| Other | 1 (0.68) | 2 (1.24) | |
| Pediatric risk of mortality score 3 | 14.06 ± 8.23 | 13.40 ± 9.66 | 0.523t |
EAS electronic alert system, SD standard deviation.
The p-value was calculated using the indicated statistics: tStudent’s t-test, *chi-squared test, MMann–Whitney U test.
Clinical interventions and outcomes comparison between the pre- and post-EAS groups.
| Variables | Pre-EAS group | Post-EAS group | |
|---|---|---|---|
Time to first dose of fluid bolus * (min.) Median (25th, 75th percentile) | 107 (37, 218) | 30 (11,112) | < 0.001M |
Time to first dose of antibiotics** (min.) Median (25th, 75th percentile) | 170.5 (66,320) | 131 (53,279) | 0.042M |
| Inotropic support | 112 (76.12) | 112 (69.56) | 0.20# |
| High-flow nasal oxygen | 58 (39.46) | 64 (39.75) | 1# |
| Conventional mechanical ventilation first hour | 37 (25.17) | 39 (24.22) | 0.895# |
| Conventional mechanical ventilation first 24 h | 68 (46.58) | 59 (36.64) | 0.081# |
| High-frequency oscillatory ventilation | 23 (15.65) | 16 (9.94) | 0.6776# |
| Mechanical ventilation duration (mean ± SD) (days) | 5.41 ± 7.71 | 5.36 ± 6.33 | 0.8988t |
| Renal replacement therapy | 10 (6.80) | 8 (4.97) | 0.6281# |
Number of organs affected Median (25th, 75th percentile) | 3(2, 3) | 2(1, 3) | 0.0117M |
PICU length of stay) (days) Median (25th, 75th percentile) | 3.08 (1.49, 8.20) | 3.71 (1.33, 9.11) | 0.976M |
| Mortality | 44 (29.93) | 28 (17.39) | 0.011# |
*Patients who received fluid bolus in Pre-group were 96/147(65.3%), vs. 112/161(69.6%) in Post-group.
**Patients who received antibiotics in Pre-group 140/147(95.2%) vs. 153/161(95%) in the post–group.
EAS electronic alert system, SD standard deviation; The p value was calculated using the indicated statistics: tStudent’s t-test, #Fisher’s exact test, MMann–Whitney U test.
Multivariate logistic regression analysis for mortality as the dependent outcome.
| Odds ratio | Estimate | 95% Confidence interval | |||
|---|---|---|---|---|---|
| Lower bound | Upper bound | ||||
| Intercept | 71.243 | < 0.001 | 4.266 | 3.105 | 5.428 |
| Age | 1.129 | 0.002 | 0.122 | 0.045 | 0.198 |
| PRISM 3 score | 0.831 | < 0.001 | −0.185 | −0.240 | −0.130 |
| Gender | 0.612 | 0.174 | −0.491 | −1.199 | 0.217 |
| Group (pre-EAS) | 0.460 | 0.027 | −0.776 | −1.462 | −0.089 |
| Mechanical ventilation in first hour | 0.497 | 0.062 | −0.699 | −1.432 | 0.034 |
PRISM 3 Pediatric Risk of Mortality III; EAS electronic alert system.
Outcome level “Survived” was coded as class 1.
Model performance metrics: area under curve = 0.857, sensitivity = 0.940, specificity = 0.500, precision = 0.860.