| Literature DB >> 35857753 |
Maurice Henkel1,2,3, Tobias Horn3,4, Francois Leboutte3,4, Pawel Trotsenko3,4, Sarah Gina Dugas3,4, Sarah Ursula Sutter3,4, Georg Ficht3,4, Christian Engesser3,4, Marc Matthias3,4, Aurelien Stalder5, Jan Ebbing3,4, Philip Cornford6, Helge Seifert3,4, Bram Stieltjes1,2,3, Christian Wetterauer3,4,7.
Abstract
PURPOSE: Rising complexity of patients and the consideration of heterogeneous information from various IT systems challenge the decision-making process of urological oncologists. Siemens AI Pathway Companion is a decision support tool that provides physicians with comprehensive patient information from various systems. In the present study, we examined the impact of providing organized patient information in comprehensive dashboards on information quality, effectiveness, and satisfaction of physicians in the clinical decision-making process.Entities:
Mesh:
Substances:
Year: 2022 PMID: 35857753 PMCID: PMC9299327 DOI: 10.1371/journal.pone.0271183
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.752
Fig 1AIPC status page: Aggregates and correlates data from patient longitudinal history, imaging and pathology reports, laboratory results, and clinical studies.
Displays a patient’s historical timeline summary of relevant clinical events. Provides historical trends and progression of key biomarkers.
Fig 2The web-based AIPC product suite consists of several components (AIPC Connector, database and applications).
The AIPC Connector is responsible for importing data from various data sources. Imported data (e.g. CSV files, SQL databases, EHR and PACS) are imported from the primary data sources and temporary stored in the Landing Zone. In the Landing Zone data are converted to a uniform data model (FHIR). The AIPC Database can import converted data through an FHIR interface. The data is then made visible to the end user on the AIPC applications in form of Dashboards, MDT reports, radiology images, etc. After decisions for a diagnostic or therapeutic measure have been made, a report can be generated within the AIPC applications for documentation purposes, which can then be sent back to the source system via a shared network file system (electronic health record (EHR).
Case characteristics.
| Case Number | Age | DRE | PSA ng/ml | Prostate Volume ml | PSA density ng/ml2 | Highest PI-RADS | Recommendation |
|---|---|---|---|---|---|---|---|
| 1 | 73 | NS | 6.4 | 28 | 0.23 | 4 | biopsy |
| 2 | 72 | NS | 2.8 | 27 | 0.10 | 3 | monitoring |
| 3 | 58 | NS | 19.7 | 48 | 0.41 | 5 | biopsy |
| 4 | 71 | NS | 11.5 | 64 | 0.27 | 5 | biopsy |
| 5 | 57 | NS | 4.8 | 37 | 0.13 | 4 | biopsy |
| 6 | 71 | NS | 8.0 | 56 | 0.14 | 5 | biopsy |
| 7 | 68 | NS | 7.5 | 19 | 0.38 | 3 | biopsy |
| 8 | 62 | NS | 6.1 | 52 | 0.12 | 4 | biopsy |
| 9 | 65 | NS | 17.0 | 109 | 0.16 | 5 | biopsy |
| 10 | 64 | NS | 5.1 | 36 | 0.14 | 5 | biopsy |
DRE = Digital Rectal Exam, NS = Non Suspicious.
Mean and standard deviation values for total case evaluation times the software vs current method as a function of user.
| Task | SPC [sec] | Current method [sec] | Difference [sec] | % Difference | p-Value |
|---|---|---|---|---|---|
| Find Patient | 6.90 | 10.40 | -3.50 | -33.62 | < 0.001 |
| Access lab values | 4.42 | 6.65 | -2.24 | -33.59 | < 0.001 |
| Evaluation lab values | 3.32 | 16.52 | -13.20 | -79.89 | < 0.001 |
| Access MRI | 17.50 | 32.92 | -15.42 | -46.85 | < 0.001 |
| Evaluate MRI | 5.05 | 8.99 | -3.94 | -43.79 | < 0.001 |
| Access clinical data | 8.15 | 27.73 | -19.58 | -70.62 | < 0.001 |
| Evaluate clinical data | 19.26 | 66.53 | -47.26 | -71.04 | < 0.001 |
| Data integration | 15.01 | 19.99 | -4.97 | -24.89 | < 0.001 |
| Recommendation | 1.83 | 1.98 | -0.15 | -7.55 | 0.051 |
| Total | 76.72 | 191.44 | -114.72 | -59.93 | < 0.001 |
Survey results of the effect size for comparison of representational information quality with current method using traditional reports and the software using charts.
| Construct | Item | Cohen’s d | 95% CI | |
|---|---|---|---|---|
| Format | “The information provided within the system is well laid out.” | 5.19 | 3.22 | 1.10 |
| "The information provided within the system clearly presented on the screen." | 6.15 | 3.90 | -0.88 | |
| Consistency | “Information within the system is accurate.” | -0.29 | -1.24 | 1.00 |
| "In general, information within the system is reliable." | 0.00 | -0.94 | 1.75 | |
| Understand- ability | “Within the system, information is easy to comprehend.” | 2.64 | 1.36 | 4.57 |
| "Within the system, information that is clear in its meaning." | 1.50 | 0.44 | 0.49 |
Fig 3The bar chart shows the time required for a physician to complete the tasks along the prostate cancer screenings pathway.
The tasks were completed once with the software and with current method.
Survey results of the effect size for comparison of contextual information quality with current method and the software.
| Construct | Item | Cohen’s d | 95% CI | |
|---|---|---|---|---|
| Completeness | “The system provides me with complete information.” | -0.33 | -1.28 | -1.28 |
| "The system produces comprehensive information." | 2.36 | 1.13 | 0.62 | |
| Relevance | “Information within the system is applicable.” | 0.59 | -0.37 | 1.13 |
| "Information with the system is relevant for my job." | -0.40 | -1.34 | 3.58 | |
| "In general, information within the system is relevant." | 0.16 | -0.78 | -0.37 | |
| Timeliness | The information provided within the system is up-to-date. | 0.06 | -0.88 | 1.55 |
| "The information provided within the system is received in a timely manner." | 3.16 | 1.75 | -1.34 | |
| Usefulness | “Information within the system is informative.” | 1.56 | 0.49 | 0.55 |
| "Information within the system is valuable." | 0.88 | -0.11 | -0.78 |
Survey results of the effect size for user satisfaction of current method and the software.
| Construct | Item | Cohen’s d | 95% CI | |
|---|---|---|---|---|
| Net benefits | "Using the ECM system increases my productivity." | 4.35 | 2.63 | 2.64 |
| Workarounds | "I always look for ways to avoid using the system." | -0.12 | -1.06 | -0.11 |
| Satisfaction | "I am satisfied with the system." | 4.94 | 3.05 | 1.86 |