Literature DB >> 35854064

Changes in anterior chamber dimensions following small incision lenticule extraction (SMILE).

Ahmet Kirgiz1, Beril Tülü Aygün2, Şenay Aşik Nacaroğlu3, Adem Tellioglu1, Yusuf Yildirim4, Burçin Kepez Yildiz1, Nilay Kandemir Beşek1, Ahmet Demirok1.   

Abstract

PURPOSE: To evaluate the changes in anterior chamber dimensions including horizontal anterior chamber diameter (HACD), anterior chamber depth (ACD), and iridocorneal angle (ICA) following small incision lenticule extraction (SMILE) using Scheimpflug-Placido disk tomographer (Sirius).
METHODS: The records of the 73 eyes of 47 patients who received SMILE for myopia and myopic astigmatism were retrospectively reviewed. Preoperative and 6-month postoperative measurements of central corneal thickness (CCT), HACD, ACD, ICA, nasal anterior chamber angle (nACA), and temporal anterior chamber angle (tACA) were obtained by tomography, and compared with paired t-tests. Pearson's correlation and linear regression tests were used to evaluate the relationship between these parameters.
RESULTS: The CCT, HACD, and ACD values decreased significantly at 6-month postoperatively (p < 0.05 for all). ICA, nACA, and tACA showed no statistically significant difference postoperatively (p = 0.54, p = 0.118, and p = 0.255, respectively). Pearson's correlation analysis confirms negative relationship between Δ-HACD and Δ-tACA (r = -0.475, p < 0.01), and a loose negative relationship between change in ACD and change in ICA (r = -0.282, p = 0.016). Age and Δ-tACA were found as predictive parameters for Δ-HACD and, Δ-ICA was a predictor for Δ-ACD.
CONCLUSION: While HACD and ACD decreased significantly, there was no significant change in ICA, nACA and tACA. Changes in HACD and ACD should be considered in terms of subsequent surgeries after SMILE.
© 2022. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Anterior segment; Iridocorneal angle; Small incision lenticule extraction; Topography

Year:  2022        PMID: 35854064     DOI: 10.1007/s10792-022-02429-9

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.029


  2 in total

1.  Intraobserver Repeatability of Corneal and Anterior Segment Parameters Obtained Using a Scheimpflug Camera-Placido Corneal Topography System.

Authors:  Elif Ertan; Mustafa Dogan
Journal:  Beyoglu Eye J       Date:  2019-08-06

2.  Anterior Chamber Angle and Volume Do Not Change after Myopic Laser-Assisted In Situ Keratomileusis in Young Patients.

Authors:  Ertuğrul Tan Yassa; Cihan Ünlü
Journal:  J Ophthalmol       Date:  2018-12-10       Impact factor: 1.909