Literature DB >> 35838911

A "bottle-around-ship" method to encapsulated carbon nitride and CdTe quantum dots in ZIF-8 as the dual emission fluorescent probe for detection of mercury (II) ion.

Piaotong Liu1, Rusi Hao1, Wenliang Sun2, Ziyi Lin1, Tianfeng Jing1, Haizhen Yang1.   

Abstract

A facile and efficient "bottle-around-ship" approach for preparing the ratiometric fluorescent probe has been developed by encapsulating the red-colored fluorescence CdTe quantum dots (QDs) and blue-colored fluorescence graphitic carbon nitride quantum dots (g-CNQDs) into the zeolitic imidazolate metal-organic frameworks (ZIF-8) in one step. At a single excitation of 360 nm, the obtained probe ZIF-8@g-CNQD/CdTe shows the dual-emission peaked at 450 and 633 nm, respectively. The red emission of CdTe QDs is selectively quenched by the Hg2+, whereas the blue fluorescence of g-CNQDs as an internal reference is insensitive, resulting in an apparent color transformation from pink to blue for special recognition of Hg2+. By this approach, the relative fluorescence intensity ratio (F633/F450) decreased linearly with increasing Hg2+ concentration in the 0.2-3.5 μM range with a low limit of detection (LOD) of ~ 46 nM. Therefore, we demonstrate that this "bottle-around-ship" process provides a new strategy for the construction of ratiometric fluorescent Hg2+ probes with good simplicity, high efficiency, and excellent stabilities. Moreover, the obtained Hg2+ fluorescent probe shows good results in the detection of actual samples.
© 2022. The Author(s), under exclusive licence to The Japan Society for Analytical Chemistry.

Entities:  

Keywords:  Graphitic carbon nitride quantum dots; Mercury (II) ion; Metal–organic frameworks; Ratiometric fluorescence

Year:  2022        PMID: 35838911     DOI: 10.1007/s44211-022-00159-7

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   1.967


  21 in total

Review 1.  Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions.

Authors:  Ha Na Kim; Wen Xiu Ren; Jong Seung Kim; Juyoung Yoon
Journal:  Chem Soc Rev       Date:  2011-12-19       Impact factor: 54.564

2.  Ultra-sensitive speciation analysis of mercury by CE-ICP-MS together with field-amplified sample stacking injection and dispersive solid-phase extraction.

Authors:  YiQuan Chen; Xian Cheng; Fan Mo; LiMei Huang; Zujian Wu; Yongning Wu; LiangJun Xu; FengFu Fu
Journal:  Electrophoresis       Date:  2015-12-29       Impact factor: 3.535

3.  Supramolecular Assembly-Induced Emission Enhancement for Efficient Mercury(II) Detection and Removal.

Authors:  Dihua Dai; Zheng Li; Jie Yang; Chunyu Wang; Jia-Rui Wu; Yan Wang; Dongmei Zhang; Ying-Wei Yang
Journal:  J Am Chem Soc       Date:  2019-03-05       Impact factor: 15.419

4.  Hg2+ Significantly Enhancing the Peroxidase-Like Activity of H2TCPP/ZnS/CoS Nanoperoxidases by Inducing the Formation of Surface-Cation Defects and Application for the Sensitive and Selective Detection of Hg2+ in the Environment.

Authors:  Ning Li; Yanlei He; Jiajia Lian; Qing-Yun Liu; Yue-Xing Zhang; Xianxi Zhang
Journal:  Inorg Chem       Date:  2020-12-02       Impact factor: 5.165

5.  Highly Efficient and Selective Hg(II) Removal from Water Using Multilayered Ti3C2Ox MXene via Adsorption Coupled with Catalytic Reduction Mechanism.

Authors:  Kaixing Fu; Xia Liu; Deyou Yu; Jinming Luo; Zhiwei Wang; John C Crittenden
Journal:  Environ Sci Technol       Date:  2020-12-01       Impact factor: 9.028

6.  Flow Injection Photochemical Vapor Generation Coupled with Miniaturized Solution-Cathode Glow Discharge Atomic Emission Spectrometry for Determination and Speciation Analysis of Mercury.

Authors:  Jiamei Mo; Qing Li; Xiaohong Guo; Guoxia Zhang; Zheng Wang
Journal:  Anal Chem       Date:  2017-09-15       Impact factor: 6.986

7.  Evaluation of different extraction procedures for determination of organic Mercury species in petroleum by high performance liquid chromatography coupled with cold vapor atomic fluorescence spectrometry.

Authors:  Zhaojun Yun; Bin He; Zhenhua Wang; Thanh Wang; Guibin Jiang
Journal:  Talanta       Date:  2012-12-14       Impact factor: 6.057

Review 8.  A review on nanostructure-based mercury (II) detection and monitoring focusing on aptamer and oligonucleotide biosensors.

Authors:  Samet Şahin; Mustafa Oguzhan Caglayan; Zafer Üstündağ
Journal:  Talanta       Date:  2020-07-24       Impact factor: 6.057

9.  Use of an aminated Amberlite XAD-4 column coupled to flow injection cold vapour generation atomic absorption spectrometry for mercury speciation in water and fish tissue samples.

Authors:  Osman Çaylak; Şükrü Gökhan Elçi; Ayşen Höl; Abdullah Akdoğan; Ümit Divrikli; Latif Elçi
Journal:  Food Chem       Date:  2018-08-31       Impact factor: 7.514

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.