| Literature DB >> 35836560 |
Geeta Hiremath1, Priya Horati1, Balaram Naik1.
Abstract
Aim: The aim of this study was to evaluate and compare the flexural strength of Cention N with resin-modified glass-ionomer cement and nanohybrid composite. Materials andEntities:
Keywords: Cention N; flexural strength; three-point bend test
Year: 2022 PMID: 35836560 PMCID: PMC9274698 DOI: 10.4103/jcd.jcd_627_21
Source DB: PubMed Journal: J Conserv Dent ISSN: 0972-0707
Summary of flexural strength (MPa) in three materials
| Materials |
| Minimum | Maximum | Mean | SD | SE | 95% CI for mean | |
|---|---|---|---|---|---|---|---|---|
|
| ||||||||
| Lower bound | Upper bound | |||||||
| Composite | 10 | 61.69 | 119.06 | 90.39 | 20.31 | 6.42 | 75.87 | 104.92 |
| RM GIC | 10 | 33.75 | 66.00 | 46.59 | 11.93 | 3.77 | 38.05 | 55.13 |
| Cention ( | 10 | 46.12 | 92.62 | 62.89 | 14.82 | 4.69 | 52.28 | 73.49 |
SD: Standard deviation, SE: Standard error, CI: Confidence interval, RM GIC: Resin-modified glass-ionomer cement
Comparison of three materials with respect to flexural strength (MPa) by one-way ANOVA test
| Sources of variation | df | Sum of squares | Mean square |
|
|
|---|---|---|---|---|---|
| Between groups | 2 | 9802.59 | 4901.30 | 18.9860 | 0.0001* |
| Within groups | 27 | 6970.28 | 258.16 | ||
| Total | 29 | 16772.87 |
*P<0.05
Pair wise comparison of three materials with respect to flexural strength (MPa) by Tukeys multiple posthoc procedures
| Materials | Mean difference | Std. Error | Sig. | 95% Confidence Interval | |
|---|---|---|---|---|---|
|
| |||||
| Lower bound | Upper bound | ||||
| Composite | |||||
| RMGIC | 43.80 | 7.1855 | 0.0001* | 25.99 | 61.62 |
| Cention N | 27.51 | 7.1855 | 0.0020* | 9.69 | 45.32 |
| RMGIC | |||||
| Cention N | -16.30 | 7.1855 | 0.0780 | -34.11 | 1.52 |
Figure 1Comparison of three materials with respect to flexural strength (MPa)