Literature DB >> 3583653

Basic imaging properties of a large image intensifier-TV digital chest radiographic system.

H Fujita, K Doi, H MacMahon, Y Kume, M L Giger, K R Hoffmann, T Katafuchi, K Ohara, H P Chan.   

Abstract

The basic imaging properties of a large (57 cm) image intensifier (I.I.)-TV digital imaging system were examined to determine the effects of various physical parameters on the quality of the digital chest images obtained, and also to explore the clinical usefulness of the system. The characteristic curve of the digital system, which relates the output pixel value to the input relative x-ray intensity, was measured with an aluminum stepwedge. MTFs were determined using slit images, and the veiling-glare fraction was measured with a lead-disk technique. Noise Wiener spectra were obtained from uniformly exposed images. The current limitations of the large II-TV digital chest system are its low spatial resolution, and the presence of large amounts of veiling glare and structure mottle. Advantages of this system over other digital chest imaging systems include the high speed of image data acquisition and the capability of "real-time" dynamic imaging of the chest at a radiation dose comparable to that in conventional radiography of the chest.

Entities:  

Mesh:

Year:  1987        PMID: 3583653     DOI: 10.1097/00004424-198704000-00009

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  11 in total

Review 1.  Biplane X-ray angiograms, intravascular ultrasound, and 3D visualization of coronary vessels.

Authors:  K R Hoffmann; A Wahle; C Pellot-Barakat; J Sklansky; M Sonka
Journal:  Int J Card Imaging       Date:  1999-12

2.  Development of pulmonary blood flow evaluation method with a dynamic flat-panel detector: quantitative correlation analysis with findings on perfusion scan.

Authors:  Rie Tanaka; Shigeru Sanada; Masaki Fujimura; Masahide Yasui; Norio Hayashi; Shiro Tsuji; Hiroyuki Okamoto; Yuko Nanbu; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2009-11-07

3.  Development of functional chest imaging with a dynamic flat-panel detector (FPD).

Authors:  Rie Tanaka; Shigeru Sanada; Masaki Fujimura; Masahide Yasui; Kazuya Nakayama; Takeshi Matsui; Norio Hayashi; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2008-04-01

4.  Development of a cardiac evaluation method using a dynamic flat-panel detector (FPD) system: a feasibility study using a cardiac motion phantom.

Authors:  Rie Tanaka; Shigeru Sanada; Katsumi Tsujioka; Takeshi Matsui; Tadanori Takata; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2007-11-01

5.  Ventilatory impairment detection based on distribution of respiratory-induced changes in pixel values in dynamic chest radiography: a feasibility study.

Authors:  Rie Tanaka; Shigeru Sanada; Masaki Fujimura; Masahide Yasui; Shiro Tsuji; Norio Hayashi; Hiroyuki Okamoto; Yuko Nanbu; Osamu Matsui
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-06-13       Impact factor: 2.924

6.  Detectability of regional lung ventilation with flat-panel detector-based dynamic radiography.

Authors:  Rie Tanaka; Shigeru Sanada; Nobuo Okazaki; Takeshi Kobayashi; Masayuki Suzuki; Takeshi Matsui; Osamu Matsui
Journal:  J Digit Imaging       Date:  2008-03       Impact factor: 4.056

7.  Pulmonary blood flow evaluation using a dynamic flat-panel detector: feasibility study with pulmonary diseases.

Authors:  Rie Tanaka; Shigeru Sanada; Masaki Fujimura; Masahide Yasui; Shiro Tsuji; Norio Hayashi; Yuko Nanbu; Osamu Matsui
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-06-04       Impact factor: 2.924

Review 8.  Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

Authors:  Rie Tanaka
Journal:  Radiol Phys Technol       Date:  2016-06-13

9.  Gastrointestinal examinations with a 2,048- x 2,048-pixel image intensifier television digital radiography system.

Authors:  Y Baba; M Takahashi; T Tsuchigami; Y Higashida
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

10.  Quantitative analysis of changes in lung density by dynamic chest radiography in association with CT values: a virtual imaging study and initial clinical corroboration.

Authors:  Teruyo Sugiura; Rie Tanaka; Ehsan Samei; William Paul Segars; Ehsan Abadi; Kazuo Kasahara; Noriyuki Ohkura; Masaya Tamura; Isao Matsumoto
Journal:  Radiol Phys Technol       Date:  2022-01-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.