Serum bactericidal assay (SBA) is the method to investigate in vitro complement-mediated bactericidal activity of sera raised upon vaccination. The assay is based on incubating the target bacteria and exogenous complement with sera at different dilutions and the result of the assay is represented by the sera dilution being able to kill 50% of bacteria present in the inoculum. The traditional readout of the assay is based on measurement of colony-forming units (CFU) obtained after plating different reaction mixes on agar. This readout is at low throughput and time consuming, even when automated counting is used. We previously described a novel assay with a luminescence readout (L-SBA) based on measurement of ATP released by live bacteria, which allowed to substantially increase the throughput as well as to reduce the time necessary to perform the assay when compared to traditional methods. Here we present a further improvement of the assay by moving from a 96-well to a 384-well format, which allowed us to further increase the throughput and substantially reduce costs while maintaining the high performance of the previously described L-SBA method. The method has been successfully applied to a variety of different pathogens.
Serum bactericidal assay (SBA) is the method to investigate in vitro complement-mediated bactericidal activity of sera raised upon vaccination. The assay is based on incubating the target bacteria and exogenous complement with sera at different dilutions and the result of the assay is represented by the sera dilution being able to kill 50% of bacteria present in the inoculum. The traditional readout of the assay is based on measurement of colony-forming units (CFU) obtained after plating different reaction mixes on agar. This readout is at low throughput and time consuming, even when automated counting is used. We previously described a novel assay with a luminescence readout (L-SBA) based on measurement of ATP released by live bacteria, which allowed to substantially increase the throughput as well as to reduce the time necessary to perform the assay when compared to traditional methods. Here we present a further improvement of the assay by moving from a 96-well to a 384-well format, which allowed us to further increase the throughput and substantially reduce costs while maintaining the high performance of the previously described L-SBA method. The method has been successfully applied to a variety of different pathogens.
Serum bactericidal assay (SBA) represents a method to determine in vitro the ability of antibodies present in serum to kill bacteria through complement activation. The assay has been established as an in vitro correlate of protection for bacterial vaccines against cholera [1] and meningococcal disease [2], and is widely used to evaluate functionality of sera raised against pathogens for which a functional assay has not been yet defined as a correlate of protection [3].In the SBA, bacteria are mixed with dilutions of heat-inactivated serum in the presence of exogenous complement. The number of live bacteria is determined at each serum dilution after a certain amount of time. The dilution of serum resulting in killing 50% of bacteria in the reaction represents the bactericidal antibody titer [4,5].The traditional SBA methods had some bottlenecks, mainly represented by the need for manually plating onto agar plates and counting the colony-forming units (CFU) both at the beginning and at the end of incubation at each serial dilution. Thus, the assay is considered time consuming and labor intensive for screening large datasets, even when automated colony-counting systems are in place.In order to overcome these issues, several groups have worked in increasing throughput [6,7]. We developed a luminescence-based high-throughput SBA (L-SBA) in 96-well format. Indeed, in our assay, the reaction mix is directly mixed with BacTiter-Glo Reagent (Promega, Madison, WI, USA), containing a thermostable luciferase and its substrate luciferin that is oxidized and thus emits light in the presence of bacterial ATP. Thus, the level of metabolic ATP released by bacteria surviving the complement-mediated killing can be detected by measuring the level of luminescent signal, which is directly proportional to the number of living bacteria in the assay wells and inversely proportional to the level of functional antibodies that are present in the serum. Hence, in the L-SBA setup, the bactericidal titer can be calculated directly at the end of the bactericidal reaction by reading the microplate in a luminometer, without the need to plate and count CFU. We demonstrated the performance of this method and the equivalence of results compared to the traditional CFU-based method against several pathogens, including Citrobacter freundii, Salmonella serovars Typhimurium and Enteritidis, Shigella flexneri serotypes 2a and 3a, Shigella sonnei, Neisseria meningitidis [8] and S. Paratyphi A [9]. We have also characterized the assay in an intralaboratory manner in terms of specificity, linearity and precision by using human sera raised against an S. sonnei GMMA-based vaccine (1790GAHB) as model, demonstrating high performance of L-SBA and further optimizing the analysis method [10]. The L-SBA method has already been extensively applied to evaluate functionality of both preclinical [11,12,13] and clinical sera from our [14] and other groups’ studies [15].Here, we present a further improvement of the L-SBA method in terms of throughput by moving from a 96-well to a 384-well format. We demonstrated consistent results and high correlation between serum titers obtained using the two L-SBA formats against different bacteria: S. sonnei, S. flexneri 1b, S. flexneri 2a, S. flexneri 3a, S. Typhimurium, S. Enteritidis, S. Paratyphi A and C. freundii. All of those pathogens represent the etiological agent of large, and often underestimated, disease burdens in low- and middle-income countries, especially in children under the age of five. Shigella and Salmonella cause significant diarrheal disease resulting in illness and death mostly in low-income countries [16]. Shigellosis is the second-leading cause of diarrheal-related mortality, with >200,000 deaths per year, globally [17]; invasive non-typhoidal Salmonella (iNTS) disease is a leading cause of morbidity and mortality among infants and HIV-positive adults in sub-Saharan Africa, with an up to 30% mortality rate [18]; enteric fever caused by S. enterica serovar Typhi and Paratyphi A is a bacteremic disease with clinical features different from those of other Gram-negative bacteremias [19]. Typhoid fever is most prevalent among children living in areas of Asia and Africa especially, where access to clean water and adequate sanitation is limited, but it is also an important travel-associated disease [20]. Based on clinical severity, disease burden and emergence of antimicrobial resistance, Shigella and Salmonella are prime targets for vaccine development [21,22,23]. The improvement of SBA in terms of throughput results is considered to be very important for the development of vaccines against both Shigella and Salmonella enteric diseases pathogens [24,25,26].
2. Materials and Methods
2.1. Bacterial Strains and Reagents
Bacterial strains used in this work are listed in Table 1. They were stored in glycerol stocks at −80 °C until use.
Table 1
Bacterial strains used in this study.
Species and Serovar
Strain
Characteristics
Reference(s)
Shigella flexneri serotype 1b
140
Clinical isolate
Public Health England (PHE)
Shigella flexneri serotype 2a
142
Clinical isolate
Public Health England (PHE)
Shigella flexneri serotype 3a
144
Clinical isolate
Public Health England (PHE)
Shigella sonnei
71
S. sonnei 53G ΔvirG::cat
[26]
Citrobacter freundii
NVGH328
Clinical isolate from Novartis Master Culture
[27]
Salmonella enterica serovar Typhimurium
D23580
Clinical isolate from blood culture, Malawi
[28,29]
Salmonella enterica serovar Enteritidis
CMCC4314
(corresponding to ATCC4931) obtained from the Novartis Master Culture Collection (NMCC)
[30]
Salmonella Paratyphi A
NVGH308
Invasive isolates, Nepal
[31]
An overnight culture (16 h at 37 °C, shaking at 180 rpm) was started from a loop of material from frozen stocks in Luria Bertani (LB) medium (Sigma-Aldrich, Saint Louis, MO, USA), supplemented with 20 µg/mL of chloramphenicol (Sigma-Aldrich, Saint Louis, MO, USA) only in the case of the S. sonnei strain. The bacterial suspension was then diluted in fresh LB to start a bacterial culture from an optical density (OD600) of 0.05 at 600 nm and incubated at 37 °C with 180 rpm agitation, until it reached 0.20–0.25 OD600.
2.2. Serum Samples
The serum samples used were polyclonal sera raised in mice or rabbits immunized with glycoconjugates (Vi-CRM197 [32,33] and O:2-CRM197 [34]), or with GMMA-based vaccines obtained from S. flexneri 1b, 2a, 3a, S. sonnei, S. Typhimurium and S. Enteritidis GMMA-producing strains [11,24,25,26,31,35].All sera tested in L-SBA were heat-inactivated (HI) at 56 °C for 30 min to remove endogenous complement activity prior to performing the L-SBA.
2.3. Luminescent-Based SBA (L-SBA) in 96- and 384-Well Plates
L-SBA was conducted in a 96-well plate (100 μL volume reaction mix containing 25,000 bacteria) format under the same assay conditions and reagent proportions as previously described [8,9] with an optimized method for raw data fitting [10]. Baby rabbit complement (BRC) from Cedarlane (Euroclone) was used as an exogenous complement source (20% BRC in the case of S. sonnei, 15% in the case of S. flexneri 1b and 3a, 7.5% in the case of S. flexneri 2a, 50% in the case of S. Typhimurium and Enteritidis, 20% in the case of S. Paratyphi A and 5% in the case of C. freundii). Phosphate-buffered saline (PBS) and LB medium (only in the case of S. flexneri 1b strain) were used for serum and bacteria dilutions for preparation of the reaction mix.Initially, L-SBA using 384-well plates was performed in the same experimental conditions established for 96-well plates. After the initial bridging, the L-SBA in 384-well format was performed using the same proportion of reagents as for 96-well plates, but in 50 μL final volume.Up to eight independent replicates of heat-inactivated test sera were serially diluted 11 times, 3-fold apart in 96-well Corning plate.An additional well containing buffer only was also added as negative control and was used for fitting purposes [10]. Furthermore, ratio of luminescence detected at T180 in wells containing buffer and BRC only and luminescence at T0 is used to evaluate the optimal growth in the assay and as quality control to validate the assay [10].Heat-inactivated sera, exogenous BRC and diluted bacteria were mixed and incubated for 180 min at 37 °C. At the end of the incubation, the plate containing the assay reaction was centrifuged at 25 °C (room temperature, RT) for 10 min at 4000× g. The supernatant was discarded to remove bacterial debris, dead bacteria and the other SBA reagents (for this step, direct aspiration using an automated liquid handler or a plate washer was implemented); the bacterial pellet was resuspended in PBS, transferred to white round-bottom 96- or 384-well plates (Greiner Bio-One, Kremsmünster, Austria) and mixed 1:1 (v:v) with BacTiter-Glo Reagent (Promega, Madison, WI, USA). After 5 min of incubation at RT on an orbital shaker, the luminescence signal was measured by a luminometer (Synergy Biotek, Winooski, VT, USA).
2.4. Calculations
For data analysis, a 4-parameter non-linear regression was applied to raw luminescence data obtained at different dilutions tested for each serum sample.Fitting was performed by weighting the data for the inverse of luminescence^2, as previously described [10].GraphPad Prism (GraphPad Software, La Jolla, CA, USA) was used for fitting and IC50 determination. IC50 corresponds to the reciprocal serum dilution necessary to obtain 50% bacterial growth inhibition (SBA titer).
3. Results
3.1. Moving from 96- to 384-Well Plates
After having verified the feasibility of performing L-SBA in 384-well plates by using the same experimental conditions (bacteria dilution, final volume reaction, BRC percentage, sera dilution volume and method for dispensing buffers or removing supernatants) established with 96-well-plates L-SBA (data not shown), we optimized the 384-well format using half of the reaction volume used for the 96-well format (50 µL rather than 100 µL, maintaining same proportion of reagents).
3.2. Comparison between L-SBA in 96- and 384-Well Plates
The relative performance of 384-well-plate L-SBA was evaluated by comparing results obtained with this method to the results of 96-well-plate L-SBA for sera raised against multiple bacteria, such as S. flexneri serotypes 1b, 2a and 3a, S. sonnei and S. serovars Typhimurium, Enteritidis and Paratyphi A.Mouse (Figure 1) and rabbit (Figure 2) reference sera were tested against the homologous strains in seven or eight independent replicates with each bactericidal reaction simultaneously assayed by both 96-well and 384-well L-SBA.
Figure 1
L-SBA titers (IC50) against S. flexneri serotypes 1b, 2a and 3a, S. sonnei, S. serovars Typhimurium, Enteritidis and Paratyphi A and C. freundii strains measured in mouse reference sera. Dots represent IC50 values corresponding to each replicate, while bars represent the related geometric means. Checkered bars represent data deriving from 96-wells-plate L-SBA, while solid bars represent data deriving from 384-wells-plate L-SBA.
Figure 2
L-SBA titers (IC50) against S. flexneri serotypes 1b, 2a and 3a, S. sonnei, S. serovars Typhimurium, Enteritidis and Paratyphi A and C. freundii strains measured in rabbit reference sera. Dots represent IC50 values corresponding to each replicate while bars represent the related geometric means. Checkered bars represent data deriving from 96-wells-plate L-SBA, while solid bars represent data deriving from 384-wells-plate L-SBA.
Similar SBA titers (IC50) were obtained by testing the same reference sera multiple times with both 96- and 384-well L-SBA format (Figure 1 and Figure 2). Moreover, very low variability in the measured IC50 was observed between the two different L-SBA formats, with standard error (SE) among replicates being less than 20% and in the majority of test samples around 10% (Table 2).
Table 2
L-SBA titers (IC50) against homologous bacteria tested as determined by L-SBA in 96- and 384-well plates in multiple independent replicates (Rep.).
L-SBA Titers (IC50)
L-SBA Titers (IC50)
96-Wells-Plate SBA
384-Wells-Plate SBA
96-Wells-Plate SBA
384-Wells-Plate SBA
S. flexneri1b Strain
Mouse Standard Antiserum
Rep. 1
8126
8490
Rabbit Standard Antiserum
Rep. 1
24,732
29,776
Rep. 2
7738
12,255
Rep. 2
25,699
31,448
Rep. 3
8257
10,670
Rep. 3
33,031
26,493
Rep. 4
9092
8694
Rep. 4
46,997
28,192
Rep. 5
8697
9869
Rep. 5
48,571
24,008
Rep. 6
10,322
8784
Rep. 6
40,635
25,847
Rep. 7
8965
13,089
Rep. 7
23,901
45,903
Rep. 8
8533
12,554
Rep. 8
28,454
GeoMean
8687
10,406
GeoMean
33,418
29,456
SE
260
621
SE
3481
2258
SE%
3
6
SE%
10
8
S. flexneri2a strain
Mouse standard antiserum
Rep. 1
8119
8905
Rabbit Standard antiserum
Rep. 1
8770
8380
Rep. 2
8473
9682
Rep. 2
11,246
9054
Rep. 3
8477
22,253
Rep. 3
12,632
18,019
Rep. 4
8450
15,172
Rep. 4
19,843
14,242
Rep. 5
8657
9233
Rep. 5
10,420
8821
Rep. 6
8741
11,761
Rep. 6
10,428
16,238
Rep. 7
8591
11,323
Rep. 7
9104
10,757
Rep. 8
8376
12,974
Rep. 8
7926
11,323
GeoMean
8484
12,116
GeoMean
10,863
11,652
SE
63
1456
SE
1243
1206
SE%
1
12
SE%
11
10
S. flexneri3a Strain
mouse Standard Antiserum
Rep. 1
46,819
24,862
Rabbit standard antiserum
Rep. 1
8811
12,624
Rep. 2
25,205
70,660
Rep. 2
11,374
21,178
Rep. 3
43,233
56,883
Rep. 3
11,343
23,076
Rep. 4
27,388
40,699
Rep. 4
16,600
17,792
Rep. 5
39,309
25,032
Rep. 5
16,928
7450
Rep. 6
34,009
24,001
Rep. 6
9086
8619
Rep. 7
32,125
24,675
Rep. 7
8417
8149
Rep. 8
26,146
23,684
Rep. 8
8141
8387
GeoMean
33,454
33,063
GeoMean
10,897
12,171
SE
2691
6030
SE
1180
2110
SE%
8
18
SE%
11
17
S. sonneiStrain
Mouse Standard Antiserum
Rep. 1
1658
2517
Rabbit standard antiserum
Rep. 1
6630
17,512
Rep. 2
1150
2290
Rep. 2
8097
9570
Rep. 3
2357
2081
Rep. 3
8673
12,372
Rep. 4
1529
2460
Rep. 4
9433
18,587
Rep. 5
1139
2489
Rep. 5
16,669
18,851
Rep. 6
1121
1068
Rep. 6
15,471
9528
Rep. 7
2014
2160
Rep. 7
8789
12,956
Rep. 8
2258
1054
Rep. 8
8342
14,005
GeoMean
1585
1912
GeoMean
9770
13,721
SE
168
201
SE
1219
1250
SE%
11
11
SE%
12
9
S.Typhimurium strain
Mouse standard antiserum
Rep. 1
28,133
16,038
Anti-rabbit standard serum
Rep. 1
61,185
25,018
Rep. 2
21,515
23,282
Rep. 2
40,788
24,404
Rep. 3
21,259
9986
Rep. 3
27,883
25,895
Rep. 4
22,669
14,926
Rep. 4
28,813
23,882
Rep. 5
25,324
18,654
Rep. 5
44,251
23,305
Rep. 6
23,509
9197
Rep. 6
27,725
21,824
Rep. 7
23,182
9208
Rep. 7
26,312
16,567
Rep. 8
8749
Rep. 8
63,920
23,675
GeoMean
23,557
12,905
GeoMean
37,765
22,888
SE
783
1777
SE
5077
956
SE%
3
14
SE%
13
4
S.Enteritidis strain
Mouse standard antiserum
Rep. 1
7984
18,043
Rabbit standard antiserum
Rep. 1
14,317
8527
Rep. 2
8327
11,270
Rep. 2
8448
9505
Rep. 3
6037
16,781
Rep. 3
8931
8681
Rep. 4
7377
13,950
Rep. 4
22,548
27,381
Rep. 5
5105
15,416
Rep. 5
25,966
25,482
Rep. 6
4482
8436
Rep. 6
22,255
9927
Rep. 7
7463
8867
Rep. 7
9179
9091
Rep. 8
7867
8457
Rep. 8
8701
8442
GeoMean
6683
12,116
GeoMean
13,532
11,793
SE
475
1293
SE
2448
2675
SE%
7
11
SE%
18
23
S.Paratyphi strain
Mouse standard antiserum
Rep. 1
6012
6008
Rabbit standard antiserum
Rep. 1
1400
941
Rep. 2
2962
4244
Rep. 2
851
1296
Rep. 3
6090
6353
Rep. 3
865
974
Rep. 4
7579
6832
Rep. 4
968
998
Rep. 5
9471
5474
Rep. 5
1748
1361
Rep. 6
8381
5657
Rep. 6
1065
775
Rep. 7
4740
4694
Rep. 7
924
1201
Rep. 8
6259
7945
Rep. 8
912
1026
GeoMean
6107
5798
GeoMean
1058
1056
SE
680
389
SE
105
65
SE%
11
7
SE%
10
6
C. freundiistrain
Mouse standard antiserum
Rep. 1
11,600
12,664
Rabbit standard antiserum
Rep. 1
1216
959
Rep. 2
9214
10,450
Rep. 2
1579
1317
Rep. 3
14,273
11,422
Rep. 3
1693
1503
Rep. 4
9719
12,792
Rep. 4
1665
1490
Rep. 5
10,345
14,563
Rep. 5
1634
1588
Rep. 6
8914
12,121
Rep. 6
1629
1222
Rep. 7
7585
11,946
Rep. 7
1539
1300
Rep. 8
12,104
Rep. 8
1195
GeoMean
10,052
12,209
GeoMean
1557
1307
SE
710
393
SE
53
67
SE%
7
3
SE%
3
5
Finally, to demonstrate equivalence of results obtained by 96- and 384-wells-plate L-SBA in the presence of the intrinsic biological variability of animal response against the same immunogen, individual rabbit sera raised against S. Typhimurium or S. Enteritidis GMMA (Figure 3) were directly compared using the two methods. By applying paired non-parametric Wilcoxon test, we did not show statistical difference between the two L-SBA methods (p = 0.1875 and p = 0.1094 for S. Typhimurium and S. Enteritidis, respectively).
Figure 3
L-SBA titers (IC50) against S. Typhimurium and S. Enteritidis strains calculated on single sera obtained after immunization of New Zealand White rabbits with a mix of individually formulated S. Typhimurium and S. Enteritidis GMMA vaccine obtained on day 14, 28, 42 and 71. Dots represent serum samples from individual rabbits.
4. Discussion
Serum bactericidal assay (SBA) is the method of choice to investigate in vitro complement-mediated bactericidal activity of antibodies present in sera, especially induced upon immunization [4,36,37]. The traditional SBA method is CFU-based, and thus depends on the laborious practice of plating bacteria on solid media at the end of the assay reaction, requiring an overnight incubation and afterwards CFU counting, so it is time consuming and at low throughput.To overcome those bottlenecks, several groups have worked in increasing throughput by developing both conventional CFU-based assays implementing automated CFU counting [6] or non-conventional SBA by measuring cellular respiration as a survival readout [38]. We have developed a luminescence-based high-throughput SBA method based on luminescence readout (L-SBA) and direct measurement of ATP released by live bacteria on the 96-well format. This method is highly reproducible and has a strong correlation between SBA titers (IC50) determined with traditional CFU counting method [8]. L-SBA has been applied to determine the functionality of sera raised against a broad range of bacterial targets, both at preclinical [11,12,13] and clinical levels [14,15]. The sensitivity of the L-SBA has been evaluated as part of an in depth characterization of the assay (data not shown) performed for each serotype: L-SBA was able to efficiently, specifically and sensibly discriminate between positive and negative samples under the same assay conditions used here.In this work, we have shown a further optimization of the L-SBA method by adapting the 96-well L-SBA to the 384-wells-plate format.We demonstrated a good concordance of results obtained using 96-well and 384-well L-SBA formats in all the cases analyzed: (1) against multiple clinically relevant enteric bacterial strains (S. sonnei, S. flexneri 1b, S. flexneri 2a, S. flexneri 3a, S. Typhimurium, S. Enteritidis, S. Paratyphi A and C. freundii); (2) using sera raised in two animal species (mice and rabbits); (3) testing independent replicates of the same reference sera or directly comparing the functionality of multiple individual single sera raised against the same vaccine.A direct comparison of the three methods (traditional CFU-based with manual counting, 96-wells-plate luminescence-based and 384-wells-plate luminescence-based SBA) in terms of performances is shown in Table 3.
Table 3
Estimation of throughput comparing traditional CFU-based method with 96- and 384-well L-SBA.
Traditional CFU-Based SBA
96-Wells-Plate L-SBA
384-Wells-Plate L-SBA
Final Volume Reaction
100 µL/well
100 µL/well
50 µL/well
Assay Time
1.5 working day
6 h
6 h
Plate Reading
2–3 h/SBA plate
2 min/SBA plate
5 min/SBA plate
Reproducibility
Lower operator independence (for manual CFU counting) than 96- and 384-wells L-SBA
High operator independence
Higher operator independence than 96-well L-SBA
Throughput
Plates/day: 2
Plates/day: 8
Plates/day: 4 (equivalent to sixteen 96-wells plates)
1 operator/1.5 day: 22 individual sera in single
1 operator/day: 88 individual sera in single
1 operator/day: 188 individual sera in single
Reagent Costs
4 EUR/serum
12 EUR/serum
8 EUR/serum
In the case of 384-well L-SBA, the assay time remained the same as the 96-well L-SBA with an apparent increase of individual plate reading. However, it needs to be considered that a 384-well plate can accommodate four 96-well-plate layouts; therefore, with the new format, the time for reading a single layout remained basically equivalent.The main achievements of 384-well L-SBA format are represented by the increase of throughput per day per operator, which goes from 88 to 188 individual sera. This increase is paralleled by a relevant cost reduction (decreasing from about twelve to around eight EUR for each serum assayed) due mostly to the reduction of the reaction volume. During the optimization, we also gained an increase of operator independence, due to the implementation of the automatic liquid handler/plate washer to discard reaction mix prior to the reading, applicable both to 96- and 384-wells L-SBA format.Overall, the assay costs of reagents were higher for L-SBA compared to traditional SBA; however, the increased throughput of L-SBA method allows one to substantially reduce the labor costs, making the use of the L-SBA method, especially in the 384-well format, attractive and competitive in terms of costs, overall very similar to the ones for the traditional method.Thus, 384-well-plate L-SBA represents a promising assay particularly for very large-scale studies, as this allows significant savings in terms of costs, time and human resources while maintaining the high performances of the previously developed and well-established 96-well-format L-SBA method. This increase in throughput is particularly important to analyze sera from clinical trials, and it opens the opportunity to analyze a larger number of sera, also against more than one strain, as the assay requires less sera volume. Therefore, this assay will be critical to support the development of vaccines against multiple bacterial targets.
Authors: Puiying A Mak; George F Santos; Kelly-Anne Masterman; Jeff Janes; Bill Wacknov; Kay Vienken; Marzia Giuliani; Ann E Herman; Michael Cooke; M Lamine Mbow; John Donnelly Journal: Clin Vaccine Immunol Date: 2011-06-29
Authors: Robert A Kingsley; Chisomo L Msefula; Nicholas R Thomson; Samuel Kariuki; Kathryn E Holt; Melita A Gordon; David Harris; Louise Clarke; Sally Whitehead; Vartul Sangal; Kevin Marsh; Mark Achtman; Malcolm E Molyneux; Martin Cormican; Julian Parkhill; Calman A MacLennan; Robert S Heyderman; Gordon Dougan Journal: Genome Res Date: 2009-11-09 Impact factor: 9.043
Authors: Mary Adetinuke Boyd; Sharon M Tennant; Venant A Saague; Raphael Simon; Khitam Muhsen; Girish Ramachandran; Alan S Cross; James E Galen; Marcela F Pasetti; Myron M Levine Journal: Clin Vaccine Immunol Date: 2014-03-12
Authors: Robert S Onsare; Francesca Micoli; Luisa Lanzilao; Renzo Alfini; Chinyere K Okoro; Anne W Muigai; Gunturu Revathi; Allan Saul; Samuel Kariuki; Calman A MacLennan; Simona Rondini Journal: PLoS Negl Trop Dis Date: 2015-03-04
Authors: Ibrahim A Khalil; Christopher Troeger; Brigette F Blacker; Puja C Rao; Alexandria Brown; Deborah E Atherly; Thomas G Brewer; Cyril M Engmann; Eric R Houpt; Gagandeep Kang; Karen L Kotloff; Myron M Levine; Stephen P Luby; Calman A MacLennan; William K Pan; Patricia B Pavlinac; James A Platts-Mills; Firdausi Qadri; Mark S Riddle; Edward T Ryan; David A Shoultz; A Duncan Steele; Judd L Walson; John W Sanders; Ali H Mokdad; Christopher J L Murray; Simon I Hay; Robert C Reiner Journal: Lancet Infect Dis Date: 2018-09-25 Impact factor: 25.071
Authors: Christiane Gerke; Anna Maria Colucci; Carlo Giannelli; Silvia Sanzone; Claudia Giorgina Vitali; Luigi Sollai; Omar Rossi; Laura B Martin; Jochen Auerbach; Vito Di Cioccio; Allan Saul Journal: PLoS One Date: 2015-08-06 Impact factor: 3.240
Authors: Helene B Juel; Helena B Thomaides-Brears; Thomas C Darton; Claire Jones; Elizabeth Jones; Sonu Shrestha; Rebecca Sie; Andrew Eustace; Ushma Galal; Prathiba Kurupati; Tan T Van; Nga T V Thieu; Stephen Baker; Christoph J Blohmke; Andrew J Pollard Journal: Front Immunol Date: 2018-01-17 Impact factor: 7.561