The pCONUS2 and pCONUS2 HPC Neck Bridging Devices : Results from an International Multicenter Retrospective Study.

L Morales-Caba1,2, I Lylyk3, V Vázquez-Añón1,2, C Bleise3, E Scrivano3, N Perez3, P N Lylyk3, J Lundquist3, P Bhogal4, P Lylyk3.   

Abstract

INTRODUCTION: Bifurcation aneurysms represent an ongoing endovascular challenge with a variety of techniques and devices designed to address them. We present our multicenter series of the pCONUS2 and pCONUS2 HPC devices when treating bifurcation aneurysms.
METHODS: We performed a retrospective review of our prospectively maintained databases at 3 tertiary neurointerventional centers to identify all patients who underwent coil embolization with the pCONUS2 or pCONUS2 HPC device between February 2015 and August 2021. We recorded baseline demographics, aneurysm data, complications, immediate and delayed angiographic results.
RESULTS: We identified 55 patients with 56 aneurysms, median age 63 years (range 42-78 years), 67.3% female (n = 37). The commonest aneurysm location was the MCA bifurcation (n = 40, 71.4%). Average dome height was 8.9 ± 4.2 mm (range 3.2-21.5 mm), average neck width 6.4 ± 2.5 mm (range 2.6-14 mm), and average aspect ratio 1.3 ± 0.6 (range 0.5-3.3). The pCONUS2 was used in 64.3% and the pCONUS2 HPC in 35.7%. The procedural technical success rate was 98.2%. Intraoperative complications occurred in 5 cases (8.9%), 4 of which were related to the coils with partial thrombus formation on the pCONUS2 HPC seen in 1 case that was resolved with heparin. In relation to the procedure and treatment of the aneurysm the overall permanent morbidity was 1.8% (n = 1/55) and mortality 0%. Delayed angiographic follow-up (48 aneurysms) at median 12 months postprocedure (range 3-36 months) demonstrated adequate occlusion of 83.4% of aneurysms.
CONCLUSION: The pCONUS2 and pCONUS2 HPC devices carry a high technical success rate, low complication and retreatment rate, and good rates of adequate occlusion. Larger prospective confirmatory studies are required.
© 2022. The Author(s).

Entities:  

Keywords:  Aneurysm; Bifurcation aneurysm; PCONUS2 HPC; PCONUS 2; Wide neck

Year:  2022        PMID: 35819477     DOI: 10.1007/s00062-022-01191-w

Source DB:  PubMed          Journal:  Clin Neuroradiol        ISSN: 1869-1439            Impact factor:   3.156


  2 in total

1.  Flow-T stenting with the Silk Vista Baby and Baby Leo stents for bifurcation aneurysms - A novel endovascular technique.

Authors:  Hld Makalanda; K Wong; P Bhogal
Journal:  Interv Neuroradiol       Date:  2019-08-26       Impact factor: 1.610

2.  The second-generation eCLIPs Endovascular Clip System: initial experience.

Authors:  Albert H Chiu; Joost De Vries; Cian J O'Kelly; Howard Riina; Ian McDougall; Jonathan Tippett; Martina Wan; Airton Leonardo de Oliveira Manoel; Thomas R Marotta
Journal:  J Neurosurg       Date:  2017-03-17       Impact factor: 5.115

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.