Literature DB >> 35819015

Letter to the Editor: "Fixation of Unstable Osteochondritis Dissecans Lesions and Displaced Osteochondral Fragments Using New Biodegradable Magnesium Pins in Adolescents".

Andreas Rehm1, Luke Granger1, Tamás Kobezda1, Joshua C Y Ong1.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35819015      PMCID: PMC9280822          DOI: 10.1177/19476035221098874

Source DB:  PubMed          Journal:  Cartilage        ISSN: 1947-6035            Impact factor:   3.117


× No keyword cloud information.
We read with interest the publication by Jungesblut and colleagues, which is 1 of 4 studies reporting on the use of MAGNEZIX® implants in children and adolescents.[1-4] Jungesblut et al. reported that complete radiographic healing of an osteochondral defect (OCD) had occurred in 12 of 19 children, but none of the provided images shows a healed defect. In contrary, the authors’ third figure shows extensive destruction of the normal trabecular bone structure with increased irregularity of a talar OCD fragment at 12 months after surgery, the fifth figure shows enlargement of a femoral OCD defect at 11 weeks with breakage of one pin and joint protrusion of 2 other pins, and the sixth figure shows non-union at 6 months, with a clear demarcation line between the femoral OCD fragment and the main bone after MAGNEZIX® pin fixation. Stürznickel et al., from the same unit as Jungesblut et al., presented one case showing partial disintegration of a lateral condyle fracture with MAGNEZIX® screw breakage at 20 weeks. Seitz et al. reported on the MAGNEZIX® screw and stated, “we are able to say with certainty that the screw disappears within 12 months,” without providing any supporting radiographic evidence. The former is also not supported by Kose et al. who provided imaging of 3 adults where the screws were still visible at 16, 21, and 24 months follow-up. Jungesblut et al. stated that all children developed a radiolucent area around the pins and quoted Kose et al. who stated that the mild radiolucent zones seen around the implants should not be discriminated with osteolysis. The Greek translation of osteolysis is bone degradation or resorption and is generally used in association with pathological processes related to a disease, joint degeneration, or implants which can be progressive or non-progressive. All publications reporting on the use of MAGNEZIX® implants in children and adolescents[1-4] show what we would describe as up to extensive bone resorption around the implants. To describe these changes as mild and to suggest that they should not be called “osteolysis” distracts from the potentially serious risk of children sustaining stress fractures because of the reduced bone strength associated with the bone loss and will result in children not being able to participate in sport for extended periods to reduce such fracture risk until the bone has reformed. None of the 4 studies including children and adolescents[1-4] reported that the patients were able to return to sportive activities and did not provide data from functional outcome scores and patient-reported outcome scores (PROMS). In conclusion, we are concerned about the use of magnesium-based implants in children and adolescents because of the up to extensive bone resorption seen around these implants, which might not be reversed up to 6 to 12 months after surgery and could potentially result in partial destruction and non-union of OCD fragments, with none of the imaging provided by Jungesblut et al. showing complete OCD healing as it was reported. The weakened bone seen around magnesium implants used for fixation of osteotomies and fractures would stop children from returning to sport for extended periods, which could cause undue stress to children and parents. We therefore think that titanium and stainless steel screws are a better implant choice for fixation of children and adolescent fractures and osteotomies, which would probably not need to be removed in the majority of cases and would allow earlier recovery of normal activities, as they are usually not associated with reduced bone strength because of bone resorption.
  5 in total

1.  Safety and performance of biodegradable magnesium-based implants in children and adolescents.

Authors:  Julian Stürznickel; Maximilian M Delsmann; Oliver D Jungesblut; Ralf Stücker; Christian Knorr; Tim Rolvien; Michael Kertai; Martin Rupprecht
Journal:  Injury       Date:  2021-03-18       Impact factor: 2.687

2.  Fixation of Unstable Osteochondritis Dissecans Lesions and Displaced Osteochondral Fragments Using New Biodegradable Magnesium Pins in Adolescents.

Authors:  Oliver D Jungesblut; Menard Moritz; Alexander S Spiro; Ralf Stuecker; Martin Rupprecht
Journal:  Cartilage       Date:  2020-07-22       Impact factor: 3.117

3.  Fixation of medial malleolar fractures with magnesium bioabsorbable headless compression screws: short-term clinical and radiological outcomes in eleven patients.

Authors:  Ozkan Kose; Adil Turan; Melih Unal; Baver Acar; Ferhat Guler
Journal:  Arch Orthop Trauma Surg       Date:  2018-04-25       Impact factor: 3.067

4.  Changes in the management of pediatric medial humeral epicondyle fractures with and without associated elbow dislocation.

Authors:  Simon Scherer; Markus Dietzel; Nicole Jordan; Ilias Tsiflikas; Hans Joachim Kirschner; Jörg Fuchs; Justus Lieber
Journal:  Injury       Date:  2021-05-30       Impact factor: 2.586

5.  Use of resorbable magnesium screws in children: systematic review of the literature and short-term follow-up from our series.

Authors:  Marco Baldini; Valentino Coppa; Danya Falcioni; Elisa Senigagliesi; Mario Marinelli; Antonio Pompilio Gigante
Journal:  J Child Orthop       Date:  2021-06-01       Impact factor: 1.548

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.