Literature DB >> 35816344

Assessment of Racial and Ethnic Differences in Oxygen Supplementation Among Patients in the Intensive Care Unit.

Eric Raphael Gottlieb1,2,3, Jennifer Ziegler4, Katharine Morley2,5, Barret Rush4, Leo Anthony Celi2,3,6,7.   

Abstract

Importance: Pulse oximetry (SpO2) is routinely used for transcutaneous monitoring of blood oxygenation, but it can overestimate actual oxygenation. This is more common in patients of racial and ethnic minority groups. The extent to which these discrepancies are associated with variations in treatment is not known. Objective: To determine if there are racial and ethnic disparities in supplemental oxygen administration associated with inconsistent pulse oximeter performance. Design, Setting, and Participants: This retrospective cohort study was based on the Medical Information Mart for Intensive Care (MIMIC)-IV critical care data set. Included patients were documented with a race and ethnicity as Asian, Black, Hispanic, or White and were admitted to the intensive care unit (ICU) for at least 12 hours before needing advanced respiratory support, if any. Oxygenation levels and nasal cannula flow rates for up to 5 days from ICU admission or until the time of intubation, noninvasive positive pressure ventilation, high-flow nasal cannula, or tracheostomy were analyzed. Main Outcomes and Measures: The primary outcome was time-weighted average supplemental oxygen rate. Covariates included race and ethnicity, sex, SpO2-hemoglobin oxygen saturation discrepancy, data duration, number and timing of blood gas tests on ICU days 1 to 3, partial pressure of carbon dioxide, hemoglobin level, average respiratory rate, Elixhauser comorbidity scores, and need for vasopressors or inotropes.
Results: This cohort included 3069 patients (mean [SD] age, 66.9 [13.5] years; 83 were Asian, 207 were Black, 112 were Hispanic, 2667 were White). In a multivariable linear regression, Asian (coefficient, 0.602; 95% CI, 0.263 to 0.941; P = .001), Black (coefficient, 0.919; 95% CI, 0.698 to 1.140; P < .001), and Hispanic (coefficient, 0.622; 95% CI, 0.329 to 0.915; P < .001) race and ethnicity were all associated with a higher SpO2 for a given hemoglobin oxygen saturation. Asian (coefficient, -0.291; 95% CI, -0.546 to -0.035; P = .03), Black (coefficient, -0.294; 95% CI, -0.460 to -0.128; P = .001), and Hispanic (coefficient, -0.242; 95% CI, -0.463 to -0.020; P = .03) race and ethnicity were associated with lower average oxygen delivery rates. When controlling for the discrepancy between average SpO2 and average hemoglobin oxygen saturation, race and ethnicity were not associated with oxygen delivery rate. This discrepancy mediated the effect of race and ethnicity (-0.157; 95% CI, -0.250 to -0.057; P = .002). Conclusions and Relevance: In this cohort study, Asian, Black, and Hispanic patients received less supplemental oxygen than White patients, and this was associated with differences in pulse oximeter performance, which may contribute to known race and ethnicity-based disparities in care.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35816344      PMCID: PMC9274443          DOI: 10.1001/jamainternmed.2022.2587

Source DB:  PubMed          Journal:  JAMA Intern Med        ISSN: 2168-6106            Impact factor:   44.409


  2 in total

1.  Skin colour affects the accuracy of medical oxygen sensors.

Authors:  Matthew D Keller; Brandon Harrison-Smith; Chetan Patil; Mohammed Shahriar Arefin
Journal:  Nature       Date:  2022-10       Impact factor: 69.504

2.  Smartphone camera oximetry in an induced hypoxemia study.

Authors:  Jason S Hoffman; Varun K Viswanath; Caiwei Tian; Xinyi Ding; Matthew J Thompson; Eric C Larson; Shwetak N Patel; Edward J Wang
Journal:  NPJ Digit Med       Date:  2022-09-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.