Literature DB >> 35814884

Vector analysis of Contoura Vision for the correction of myopia and myopic astigmatism.

Ying Lin1, Huan-Jun Su1, Mu-Zhi Yuan1, Yong Zhang2.   

Abstract

AIM: To evaluate the visual outcomes of Contoura Vision (CV) with automatic eye tracking system in eyes with myopia and myopic astigmatism.
METHODS: This prospective study included 160 eyes (80 patients) with moderate myopia and irregular astigmatism between January and August 2018. Subjects were randomly divided into CV group (80 eyes) that underwent CV femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and a control group (80 eyes) that underwent wavefront-optimized FS-LASIK. Visual outcomes and astigmatic vector analysis were evaluated and compared between preoperatively and 3mo postoperatively.
RESULTS: Basic details were similar in both groups (P>0.05). At 3mo postoperatively, uncorrected distance visual acuity was 20/16, 20/20, and 20/25 in 24, 76, and 80 eyes of patients in CV group, respectively. The CV group was better in predictability of astigmatism correction at 3mo postoperatively. In CV group, 64 eyes had deviation of astigmatic axis within 15° and 28 eyes had deviation of astigmatic axis within 5°, both were better than those in the control group. The number of eyes with residual astigmatism within 0.5 D were less in CV group (48 eyes) than the control group (40 eyes). Compared with the preoperative, C7 significantly reduced to 0.056±0.030 in CV group at 3mo after the procedure (P<0.05), and were significantly lower than those in the control group (P<0.05).
CONCLUSION: CV with automatic eye tracking system is safe and effective for the correction of myopia and myopic astigmatism. International Journal of Ophthalmology Press.

Entities:  

Keywords:  Contoura Vision; irregular astigmatism; vector analysis

Year:  2022        PMID: 35814884      PMCID: PMC9203487          DOI: 10.18240/ijo.2022.06.17

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.645


  26 in total

1.  A Prospective Study to Compare Visual Outcomes Between Wavefront-optimized and Topography-guided Ablation Profiles in Contralateral Eyes With Myopia.

Authors:  Rohit Shetty; Rushad Shroff; Kalyani Deshpande; Roshan Gowda; Sumeet Lahane; Chaitra Jayadev
Journal:  J Refract Surg       Date:  2017-01-01       Impact factor: 3.573

2.  Minimum amount of astigmatism that should be corrected.

Authors:  Eloy A Villegas; Encarna Alcón; Pablo Artal
Journal:  J Cataract Refract Surg       Date:  2014-01       Impact factor: 3.351

3.  [Dynamic aberrometry during accommodation of phakic eyes and eyes with potentially accommodative intraocular lenses].

Authors:  H B Dick; St Kaiser
Journal:  Ophthalmologe       Date:  2002-11       Impact factor: 1.059

4.  Wavefront-optimized ablation versus topography-guided customized ablation in myopic LASIK: comparative study of higher order aberrations.

Authors:  Hatem E El Awady; Asaad A Ghanem; Sameh M Saleh
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2011-04-28

5.  Comparison of Wavefront-Optimized Ablation and Topography-Guided Contoura Ablation With LYRA Protocol in LASIK.

Authors:  Kemal Ozulken; Erdem Yuksel; Kemal Tekin; Hasan Kiziltoprak; Semih Aydogan
Journal:  J Refract Surg       Date:  2019-04-01       Impact factor: 3.573

Review 6.  Astigmatism and toric intraocular lenses.

Authors:  C Novis
Journal:  Curr Opin Ophthalmol       Date:  2000-02       Impact factor: 3.761

7.  A new method of analyzing vectors for changes in astigmatism.

Authors:  N A Alpins
Journal:  J Cataract Refract Surg       Date:  1993-07       Impact factor: 3.351

8.  Outcomes of LASIK for myopia with FDA-approved lasers.

Authors:  Melissa D Bailey; Karla Zadnik
Journal:  Cornea       Date:  2007-04       Impact factor: 2.651

9.  The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 3: the results of 50 treated eyes.

Authors:  Manoj Motwani
Journal:  Clin Ophthalmol       Date:  2017-05-16

10.  The use of WaveLight Contoura to create a uniform cornea: 6-month results with subjective patient surveys.

Authors:  Manoj Motwani; Ronald Pei
Journal:  Clin Ophthalmol       Date:  2018-08-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.