| Literature DB >> 35812009 |
Hubert Benoist1, Clarisse Eveno2, Sarah Wilson3, Nicolas Vigneron3, Jean-Marc Guilloit4, Rémy Morello3, Nicolas Simon5, Pascal Odou5, Guillaume Saint-Lorant1,5.
Abstract
Objectives: Two surgical techniques used for peritoneal metastasis involve a risk of exposure to antineoplastic drugs (ADs): hyperthermic intraperitoneal chemotherapy (HIPEC) and pressurized intraperitoneal aerosol chemotherapy (PIPAC). The objective of this study was to assess the differences in perception, training, and knowledge of the risks as well as in the protection practices and occupational exposures of all worker categories.Entities:
Keywords: HIPEC; PIPAC; antineoplastic drugs; occupational risks
Year: 2022 PMID: 35812009 PMCID: PMC9166181 DOI: 10.1515/pp-2021-0151
Source DB: PubMed Journal: Pleura Peritoneum ISSN: 2364-768X
Participants’ characteristics.
| Overall | Medical staff | Nursing staff | Auxiliary caregivers | ||
|---|---|---|---|---|---|
| Effectives, n (%) | 51 (100) | 10 (19.6) | 20 (39.2) | 21 (41.2) | |
| Gender | Female, n (%) | 30 (58.8) | 3 (30) | 13 (65) | 14 (66.7) |
| Male, n (%) | 21 (41.2) | 7 (70) | 7 (35) | 7 (33.3) | |
| Job tenure in the hospital, mean ± SD (range), months | 137.6 ± 115.1 (2–467) | 57.3 ± 74.5 (2–251) | 160.4 ± 98.4 (7–419) | 154.2 ± 131.9 (36–467) | |
| Job tenure in operating rooms, mean ± SD (range), months | 94.4 ± 72.1 (7–275) | 75.7 ± 76.3 (12–251) | 111.1 ± 79.9 (7–275) | 87.5 ± 61.7 (24–251) | |
| Mean job tenure in HIPEC, mean ± SD (range), months | 43.8 ± 44.4 (1–168) | 27.3 ± 44.5 (1–144) | 68.1 ± 51.6 (7–168) | 28.5 ± 23.2 (12–120) | |
| Mean job tenure in PIPAC, mean ± SD (range), months | 12.1 ± 11.1 (<1–36) | 12.3 ± 10.3 (1–24) | 15.8 ± 13.2 (<1–36) | 7.8 ± 7.4 (4–24) | |
| Age, mean ± SD (range), years | 40.0 ± 9.3 (24–58) | 35.3 ± 8.3 (27–56) | 41.3 ± 7.4 (30–58) | 41.1 ± 11.0 (24–57) | |
Participants’ characteristics.
| Questions | Overall (n=51) | Medical staff (n=10) | Nursing staff (n=20) | Auxiliary caregivers (n=21) | p-Value | |
|---|---|---|---|---|---|---|
| Fear of handling AD [Q3] | Agree | 15 (29.4) | 1 | 3 | 11 |
|
| Disagree | 36 (70.6) | 9 | 17 | 10 | ||
| The toxicity risk level is the same for all AD [Q4] | Agree | 8 (15.7) | 2 | 4 | 2 | 0.598 |
| Disagree + Don’t know | 43 (84.3) | 8 | 16 | 19 | ||
| The safety measures currently in place sufficiently reduce the risk of contamination [Q5] | Agree | 38 (74.5) | 8 | 15 | 15 | 1.000 |
| Disagree + Don’t know | 13 (25.5) | 2 | 5 | 6 | ||
| I am confident that I can handle all situations with a potential risk of exposure to AD [Q6] | Agree | 25 (49.0) | 7 | 7 | 11 | 0.187 |
| Disagree + Don’t know | 26 (51.0) | 3 | 13 | 10 | ||
| Initial training on the handling of AD (at nursing school, medical school, etc.) [Q7] | Yes | 3 (5.9) | 1 | 2 | 0 | 0.297 |
| No | 48 (94.1) | 9 | 18 | 21 | ||
The bold values indicate a significant difference p < 0.05.
Perception questions.
| Questions | Procedure performed | Concordance | |||||
|---|---|---|---|---|---|---|---|
| HIPEC (n=38) | PIPAC (n=38) | p-Value | Kappa | p-Value | Agreement | ||
| Risk exposure assessment [Q13 Q31] | Very low | 7 | 16 |
| 0.240 | 0.108 | 65.8 |
| ≥ Low | 31 | 22 | |||||
| Suitable protective equipment [Q14 Q32] | Agree | 27 | 34 |
| 0.448 | 0.005 | 81.6 |
| Disagree + Don’t know | 11 | 4 | |||||
The bold values indicate a significant difference p < 0.05.
Perception questions by worker categories.
| Questions | Worker category n=38 | ||||
|---|---|---|---|---|---|
| Medical staff (n=6) | Nursing staff (n=17) | Auxiliary caregivers (n=15) | p-Value | ||
| Risk exposure assessment for HIPEC [Q13] | Very low | 3 | 4 | 0 |
|
| ≥ Low | 3 | 13 | 15 | ||
| Risk exposure assessment for PIPAC [Q31] | Very low | 5 | 9 | 2 |
|
| ≥ Low | 1 | 8 | 13 | ||
| Is protective equipment suitable for HIPEC ? [Q14] | Agree | 6 | 12 | 9 | 0.247 |
| Disagree + Don’t know | 0 | 5 | 6 | ||
| Is protective equipment suitable for PIPAC ? [Q32] | Agree | 6 | 16 | 12 | 0.362 |
| Disagree + Don’t know | 0 | 1 | 3 | ||
The bold values indicate a significant difference p < 0.05.
Knowledge questions.
| Questions | Procedure performed (n=38) | Concordance | ||||||
|---|---|---|---|---|---|---|---|---|
| HIPEC | PIPAC | p-Value | Kappa | p-Value | Agreement | |||
| Ongoing training specific to this technique [Q15 Q33] | Yes | 12 | 5 |
| 0.350 | 0.026 | 76.3 | |
| No | 26 | 33 | ||||||
| Potential contamination by: | Injectable route [Q19a Q37g] | Agree | 22 | 14 |
| 0.596 | <0.001 | 78.9 |
| Disagree | 16 | 24 | ||||||
| Cutaneous route [Q19b Q37h] | Agree | 35 | 24 |
| 0.121 | 0.548 | 65.8 | |
| Disagree | 3 | 14 | ||||||
| Inhaled route [Q19c Q37i] | Agree | 22 | 25 | 0.607 | 0.169 | 0.315 | 60.5 | |
| Disagree | 16 | 13 | ||||||
| Ocular route [Q19d Q37j] | Agree | 31 | 19 |
| 0.263 | 0.086 | 63.2 | |
| Disagree | 7 | 19 | ||||||
| Oral route [Q19e Q37k] | Agree | 21 | 15 | 0.109 | 0.485 | 0.002 | 73.7 | |
| Disagree | 17 | 23 | ||||||
| Infusion bags [Q20a Q38a] | Agree | 23 | 25 | 0.625 | 0.774 | <0.001 | 89.5 | |
| Disagree | 15 | 13 | ||||||
| Operating table [Q20d Q38d] | Agree | 33 | 25 |
| 0.177 | 0.309 | 68.4 | |
| Disagree | 5 | 13 | ||||||
| Trolley surfaces [Q20e Q38e] | Agree | 24 | 16 | 0.057 | 0.293 | 0.085 | 63.2 | |
| Disagree | 14 | 22 | ||||||
| Screen surfaces [Q20f Q38f] | Agree | 21 | 14 | 0.143 | 0.129 | 0.506 | 55.3 | |
| Disagree | 17 | 24 | ||||||
| Ventilator [Q20g Q38g] | Agree | 18 | 14 | 0.424 | 0.253 | 0.178 | 63.2 | |
| Disagree | 20 | 24 | ||||||
| Operating room telephone [Q20h Q38h] | Agree | 22 | 19 | 0.508 | 0.526 | 0.002 | 76.3 | |
| Disagree | 16 | 19 | ||||||
| Computer keyboard [Q20i Q38i] | Agree | 21 | 18 | 0.508 | 0.529 | 0.002 | 76.3 | |
| Disagree | 17 | 20 | ||||||
| Door detector [Q20j Q38j] | Agree | 16 | 15 | 1.000 | 0.401 | 0.019 | 71.1 | |
| Disagree | 22 | 23 | ||||||
| Floor [Q20k Q38k] | Agree | 36 | 29 |
| 0.304 | 0.055 | 81.6 | |
| Disagree | 2 | 9 | ||||||
| Walls [Q20l Q38l] | Agree | 23 | 17 | 0.146 | 0.382 | 0.020 | 68.4 | |
| Disagree | 15 | 21 | ||||||
| Smoke evacuation system [Q20m Q38m] | Agree | 23 | 22 | 1.000 | 0.510 | 0.003 | 76.3 | |
| Disagree | 15 | 16 | ||||||
| Other [Q20n Q38o] | Yes | 5 | 1 | 0.125 | 0.303 | 0.135 | 89.5 | |
| No | 33 | 37 | ||||||
The bold values indicate a significant difference p < 0.05.
Knowledge questions by worker categories.
| Questions | Worker category (n=38) | |||||
|---|---|---|---|---|---|---|
| Medical staff (n=6) | Nursing staff (n=17) | Auxiliary caregivers (n=15) | p-Value | |||
| Ongoing training specific to this technique for HIPEC [Q15] | Yes | 1 | 2 | 9 |
| |
| No | 5 | 15 | 6 | |||
| Ongoing training specific to this technique for PIPAC [Q33] | Yes | 1 | 2 | 2 | 1.000 | |
| No | 5 | 15 | 13 | |||
| HIPEC potential contamination by: | Injectable route [Q19a] | Agree | 3 | 7 | 12 | 0.084 |
| Disagree | 3 | 10 | 3 | |||
| Cutaneous route [Q19b] | Agree | 4 | 17 | 14 |
| |
| Disagree | 2 | 0 | 1 | |||
| Ocular route [Q19d] | Agree | 4 | 15 | 12 | 0.478 | |
| Disagree | 2 | 2 | 3 | |||
| Operating table [Q20d] | Agree | 4 | 16 | 13 | 0.216 | |
| Disagree | 2 | 1 | 2 | |||
| Floor [Q20k] | Agree | 4 | 17 | 15 |
| |
| Disagree | 2 | 0 | 0 | |||
| PIPAC potential contamination by: | Injectable route [Q37g] | Agree | 1 | 2 | 11 |
|
| Disagree | 5 | 15 | 4 | |||
| Cutaneous route [Q37h] | Agree | 2 | 10 | 12 | 0.129 | |
| Disagree | 4 | 7 | 3 | |||
| Ocular route [Q37j] | Agree | 2 | 7 | 10 | 0.320 | |
| Disagree | 4 | 10 | 5 | |||
| Operating table [Q38d] | Agree | 2 | 11 | 12 | 0.146 | |
| Disagree | 4 | 6 | 3 | |||
| Floor [Q38k] | Agree | 3 | 12 | 14 | 0.075 | |
| Disagree | 3 | 5 | 1 | |||
The bold values indicate a significant difference p < 0.05.
Practice questions.
| Questions | Procedure performed (n=38) | Concordance | |||||
|---|---|---|---|---|---|---|---|
| HIPEC | PIPAC | p-Value | Kappa | p-Value | Agreement | ||
| Bio-decontamination procedure knowledge [Q21 Q39] | Yes | 31 | 25 | 0.109 | 0.343 | 0.037 | 73.7 |
| No + Don’t know | 7 | 13 | |||||
| If yes, can you explain it? | Yes | 15 | 15 | 1.000 | 0.850 | <0.001 | 92.6 |
| No | 12 | 12 | |||||
| Wearing gloves [Q22 Q40] | Always | 37 | 32 | 0.063 | 0.252 | 0.160 | 86.8 |
| Not always | 1 | 6 | |||||
| Wearing a mask [Q23 Q41] | Always | 36 | 35 | 1.000 | 0.360 | 0.158 | 92.1 |
| Not always | 2 | 3 | |||||
| Wearing protective goggles [Q24 Q42] | Always | 25 | 20 | 0.125 | 0.625 | <0.001 | 81.6 |
| Not always | 13 | 18 | |||||
| Wearing a gown [Q25 Q43] | Always | 33 | 24 |
| 0.412 | 0.004 | 76.3 |
| Not always | 5 | 14 | |||||
| Mean annual number of interventions [Q26 Q44] | <10 | 13 | 13 | 1.000 | 0.766 | <0.001 | 89.5 |
| ≥10 | 25 | 25 | |||||
| Bio-decontamination activity [Q27 Q45] | Yes | 21 | 17 | 0.125 | 0.792 | <0.001 | 89.5 |
| No | 17 | 21 | |||||
| If yes, frequency of bio-decontamination | Each patient | 14 | 15 | 1.000 | – | – | 94.1 |
| Once a day | 3 | 2 | |||||
| Use of a proper technique for bio-decontamination | Yes | 14 | 14 | 1.000 | 1.000 | 0.065 | 100.0 |
| No | 1 | 1 | |||||
| Negative symptoms perceived when not exposed [Q28 Q46] | Yes | 6 | 1 | 0.125 | −0.047 | 1.000 | 81.6 |
| No | 32 | 37 | |||||
| Ever exposed to AD [Q29 Q47] | Yes | 2 | 3 | 1.000 | −0.067 | 1.000 | 86.8 |
| No | 36 | 35 | |||||
The bold values indicate a significant difference p < 0.05.
Practice questions by worker categories.
| Questions | Worker category n=38 | ||||
|---|---|---|---|---|---|
| Medical staff (n=6) | Nursing staff (n=17) | Auxiliary caregivers (n=15) | p-Value | ||
| Wearing a gown [Q25] | Always | 4 | 16 | 13 | 0.218 |
| Not always | 2 | 1 | 2 | ||
| Wearing a gown [Q43] | Always | 4 | 8 | 12 | 0.159 |