Ying Chang1, Donghui Fu1,2, Mingyuan Sun1, Saisai He1, Wei Qiu1,2. 1. Department of Mechanics, School of Mechanical Engineering, Tianjin University, Tianjin 300072, China. 2. Tianjin Key Laboratory of Modern Engineering Mechanics, Tianjin 300072, China.
Abstract
Micro Raman spectroscopy is an effective method to quantitatively analyse the internal stress of semiconductor materials and structures. However, the decoupling analysis of the stress components for {100} monocrystalline silicon (c-Si) remains difficult. In the work outlined, physical and simulation experiments were combined to study the influence of the objective lens numerical aperture (NA) on the Raman stress characterization. The physical experiments and simulation experiments show that the spectral results obtained by using lenses with different NAs can accurately obtain the principal stress sum but cannot decouple the components of the in-plane stress. Even if the spectral resolution of the simulated experiment is ideal (The random errors of the polarization directions of less than ±1° and the systematic random errors of less than ±0.02 cm-1). The analysis based on the theoretical model demonstrates that the proportion of the principal stress sum in the Raman shift obtained in an actual experiment exceeded 98.7%, while the proportion of the principal stress difference part was almost negligible. This result made it difficult to identify the variable effects of different stress states from the experimental results. Further simulation experiments in this work verify that when the principal stress sum was identical, the differences in the Raman shifts caused by different stress states were much smaller than the resolution of the existing Raman microscope system, which was hardly possible to identify in the experimental results. It was proven that decoupling analysis of stress components using the large-NA objective lens lacked actual practicability.
Micro Raman spectroscopy is an effective method to quantitatively analyse the internal stress of semiconductor materials and structures. However, the decoupling analysis of the stress components for {100} monocrystalline silicon (c-Si) remains difficult. In the work outlined, physical and simulation experiments were combined to study the influence of the objective lens numerical aperture (NA) on the Raman stress characterization. The physical experiments and simulation experiments show that the spectral results obtained by using lenses with different NAs can accurately obtain the principal stress sum but cannot decouple the components of the in-plane stress. Even if the spectral resolution of the simulated experiment is ideal (The random errors of the polarization directions of less than ±1° and the systematic random errors of less than ±0.02 cm-1). The analysis based on the theoretical model demonstrates that the proportion of the principal stress sum in the Raman shift obtained in an actual experiment exceeded 98.7%, while the proportion of the principal stress difference part was almost negligible. This result made it difficult to identify the variable effects of different stress states from the experimental results. Further simulation experiments in this work verify that when the principal stress sum was identical, the differences in the Raman shifts caused by different stress states were much smaller than the resolution of the existing Raman microscope system, which was hardly possible to identify in the experimental results. It was proven that decoupling analysis of stress components using the large-NA objective lens lacked actual practicability.
The development of semiconductor science and information devices has become an essential condition to promote artificial intelligence, electronic communication, automotive electronics, big data centres and other fields. The performance of semiconductor devices is supported by material advancement from traditional semiconductor materials (silicon, germanium) to third-generation semiconductor materials (gallium nitride, silicon carbide) to ultrawide bandgap semiconductor materials (diamond, gallium oxide). This continuously promotes the innovation and development of radio frequency communication, high-power devices, lighting devices, etc. One of the keys that affect the semiconductor device performance is strain engineering [1,2], whose foremost requirement is precise control of stress.The internal stress in a semiconductor device is spatially unevenly distributed and in a complex stress state due to the complexity of the structure. Studies have shown that the stress state is the dominant factor that affects the device reliability [3] and the crucial factor that affects the electron mobility [4] and quantum spin [5] of semiconductors. The accurate quantitative characterization of the stress or strain state of semiconductors is a vital segment in the design and manufacture of microelectronics and a frontier scientific issue at the intersection of solid-state physics and experimental mechanics.There are many microscale experimental mechanical methods to characterize stress states, such as X-ray diffraction (XRD), TEM moiré, and micro-Raman spectroscopy. Among them, micro-Raman spectroscopy has achieved many applications in the characterization of internal stresses in low-dimensional materials, the analysis of microdevice processes and residual stresses, and the mechanical behaviour of microscale interfaces due to its advantages of high resolution, nondestructive noncontact, sensitivity to both intrinsic and nonintrinsic stresses. Zhao et al. [6,7,8,9,10] studied stress or strain in fracture characteristics, boundary effects, transfer, interface reinforcement of graphene by Raman spectroscopy. The investigations of Xie et al. [11,12,13,14,15] found that lithium storage behaviour, capacity and lifetime of graphene electrodes lithium-ion (Li+) batteries are strongly affected by the microstructure and stress/strain. There are still several bottlenecks that must urgently be solved, although much evolution has been made in terms of its characterization theoretical model, critical experimental techniques, and high-level analytical instruments in recent years. Prominently, the decoupling problem of stress state components for typical materials has become a common and difficult problem in Raman stress analysis.In the existing research, the basic mentality of stress state analysis using micro-Raman spectroscopy is as follows. Substituting the stress–strain relationship into the lattice dynamics secular equation and solving the relationship between each component of the stress tensor and the Raman shift, the analytical expression of the relationship between the measured Raman shift and the stress component is obtained based on the Raman selection rule. De Wolf derived the stress-Raman shift relationship under uniaxial stress and biaxial stress based on simplification by neglecting the shear stress for c-Si [16]. Ma et al. proved that the backscattering Raman measurement results of {100} c-Si were independent of the shear stress through theoretical derivation and calibration experiments, which is due to the triple degeneracy of the Raman peaks of c-Si. Decoupling analysis of stress components cannot be achieved because the Raman shift is linearly related to the sum of the principal stresses [17,18]. To decouple stress components, Loechelt et al. proposed a method for decoupling analysis using off-axis measurement and developed a related device [19]. Fu et al. used a Raman measurement method based on oblique backscattering to realize the decoupling of in-plane bidirectional stress [20]. In contrast, most applied studies have focused on the inability to decouple measurements by resorting to theoretical models of elasticity [21], finite element analysis [22], simplifying assumptions on stress states [23], or simply ignoring stress states and actually treating stresses as scalars [24].In recently years, several published works claimed that the stress/strain states of {100} c-Si were or could be decoupled through MRS with large numerical aperture (NA) lenses. Some researchers have found that Raman measurements with large-NA objective lens can activate the forbidden TO mode of {100} c-Si, which obtains more abundant Raman information to help decouple the stress components. Kosemura observed transverse optical phonons of {100} c-Si with a large-NA lens [25]. Brunner et al. determined the biaxial stress at the SiO2/Si interface by using a Raman selection rule and a finite solid angle of collection, which can monitor all modes in the [001] crystalline SiO2/Si structure [26]. In addition, some other works have been performed using large-NA objectives. However, their stress states are uniaxial or biaxial in fact [26,27,28,29], which is not relevant to the decoupling analysis of complex stress states (regardless of what they claim [30]). Furthermore, for complex silicon samples such as polysilicon and textured silicon [27,31], experiments have shown that a large NA (NA > 0.4) indeed provides more abundant experimental information than a small NA (NA ≤ 0.4) [28,30,32]. However, there has been a lack of a theoretical and experimental basis for the problem of decoupling the analysis of complex stress states with large-NA objective lenses, such as {100} c-Si.For these issues, some influences were introduced into the Raman-stress characterization model, such as refraction, receding deflection, and large NA, based on the basic theory of experimental mechanical characterization. The analytical relationship between the measured Raman shift and the in-plane stress components was derived for different NA backscattering configurations. The effect of the objective lens NA on the stress characterization in the micro-Raman system was quantitatively verified by a combination of physical and simulation experiments.
2. Materials and Experiments
2.1. Physical Experiments
Double-polished (100) c-Si was invoked as the sample (Guangzhou Fangdao Semiconductor Co., Ltd., Guangzhou, China). The Raman experiments were performed using a self-developed microscopic Raman device [33], which was scanned and probed in the HV-case (HV-case was defined when the polarization direction of incident laser was perpendicular to that of scattering light, i.e., γ = φ + 90°) and vertical backscattering configurations using objective lenses with NA = 0.55, NA = 0.7, and NA = 0.8, respectively. The mapping region was 0.9 mm × 1.2 mm in the centre of the sample with a sampling point spacing of 0.3 mm and 20 points in total and repeat once. All experiments had an identical integration time of 3 s, a 532 nm laser output power of 150 mW, a spectrometer grating of 1800 L/mm. In general, laser power should be kept below a few tens of µW to reduce thermal effects [34,35]. To eliminate thermal effects, the relative increment of Raman shift between the state under stress and that of stress-free is used in the experiments.The samples were loaded as shown in Figure 1 with compressive stresses of σS1 = −117.84 MPa and σS2 = −58.78 MPa for sample 1 and sample 2, respectively. After the calculation, the stress components in the crystal coordinate system are given in Table 1.
Figure 1
Schematic diagram of the sample loading method: (a) sample 1; (b) sample 2.
Table 1
Stress components and principal stress sum of sample 1 and sample 2.
σ11/MPa
σ22/MPa
τ12/MPa
(σ11 + σ22)/MPa
Sample 1
−117.60
−0.24
−5.34
−117.84
Sample 2
−29.39
−29.39
−29.39
−58.78
2.2. Simulation Experiments
Origin (2018, 9.5) was employed for simulation experiments. First, the principal stress difference coefficients were given for six different NAs (NA is 0.28, 0.55, 0.70, 0.80, 0.95, and 1.30) based on the Raman shift-stress relationship considering the NA, and the fraction of the non-principal stress sum was obtained as a percentage of the total Raman shift. Subsequently, two stress states with identical principal stress sum but different stress components, i.e., biaxial (σ11 = σ22 = −500 MPa) and unequal biaxial (σ11 = −700 MPa, σ22 = −300 MPa), were chosen to give the expected Raman shifts of the angle-resolved Raman spectra at different NAs in steps of 10° of the polarization direction.
3. Models and Methods
The process of establishing the Raman-stress relationship is shown in Figure 2.
Figure 2
General Raman-stress relationship model building flow chart.
According to the generalized Hooke’s law in elasticity theory, there is a linear relationship between stress and strain in the case of small deformation, and its general form is shown in Equation (1).
where is the strain tensor, is the elasticity tensor, and is the stress tensor.The lattice dynamics secular equation for the effect of strain is shown in Equation (2).
where ε is the strain component, K is the phonon deformation potential tensor component, and K, i, j = 1, 2, 3. The eigenvalues λ (k = 1, 2, 3) and corresponding eigenvectors are obtained by solving Equation (2). Let the Raman shifts in the strain-free and strained states of the lattice be ω0 and ω, respectively, λ = ω2 − ω02. Generally, the difference between ω0 and ω is small, so the Raman shift increment Δω can be approximated as Equation (3).In the measured Raman spectral information, the intensity of each characteristic peak I is determined by the Raman selection rule, as shown in Equation (4).
where and are the polarization vectors of incident laser and scattering light, respectively, and is the Raman tensor in the crystal coordinate system. The Raman intensity is actually the sum of the Raman scattering light excited by incident laser in the optic cone [33]. The Raman scattering intensity is integrated in different directions within the optic cone under the microscope (as shown in Figure 3) as shown in Equation (5), where α is the angle between the projection of the light in the X-Y plane and the X-axis, and α ∈ [0, 2π]; β is the angle between the light and the lens axis (i.e., Z-axis), and β ∈ [0, arcsin(NA)]. A general formula for the Raman intensity is given as Equation (5) based on [33] in this paper, where F is the integration result of the intensity of each Raman characteristic peak I.
Figure 3
Diagram of the Raman intensity integration with a large-NA objective lens.
The relationship between the measured Raman shift Δω and the increment of each phonon Raman shift Δω weighted by their respective contributions to the total scattering intensity is shown in Equation (6).The Raman shift-stress relationship for the specific NA can be obtained as shown in Equation (7) using Equations (1)–(6), where the stress unit is GPa.
where,In Equation (8), φ and γ are the polarization directions of incident laser and scattering light, respectively. In this paper, the HH-case was defined when the polarization direction of the incident laser was parallel to that of the scattering light, i.e., φ = γ. The HV-case was defined when the polarization direction of the incident laser was perpendicular to that of the scattering light, i.e., γ = φ + 90°. The coefficients a1, b1, c1, a2, b2, and c2 were calculated by integrating Equation (5). These coefficients are given in Table 2 for different values of different NAs.
Table 2
Coefficients a1, b1, c1, a2, b2, and c2 values for different NAs.
a1
b1
c1
−a2
−b2
−c2
NA = 0.20
0.0105
0.0006
0.0048
0 *
0 *
0.0004
NA = 0.28
0.0209
0.0011
0.0097
0.0003
0 *
0 *
NA = 0.42
0.0495
0.0026
0.0225
0.0023
0.0009
0.0007
NA = 0.55
0.0909
0.0041
0.0397
0.0059
0.0004
0.0023
NA = 0.70
0.1684
0.0066
0.0663
0.0198
0.0007
0.0080
NA = 0.80
0.2526
0.0084
0.0916
0.0446
0.0012
0.0157
NA = 0.95
0.1957
0.0065
0.0710
0.0346
0.0010
0.0121
NA = 1.30
0.1360
0.0045
0.0493
0.0240
0.0007
0.0084
* indicates a value less than 5 × 10−5.
In the HH-case, parameters K1 and K2 became,In the HV-case, parameters K1 and K2 became,
4. Results and Discussion
The physical experimental results for sample 1 at different NAs in Figure 4. The black solid points are the experimentally measured data points, the red curve is the theoretical result for the stress state, and the purple curve is the fitted result using Equation (7). When NA = 0.55, the fitted curve differs from the theoretical curve more, and even the trend is not consistent from Figure 4a. When NA = 0.7 and NA = 0.8, the fitted curves follow the same trend as the theoretical curves but do not completely overlap in Figure 4b,c. The results of fitted stress components for NA = 0.55 are σ11/0.55 = −1770.36 MPa, σ22/0.55 = 1657.67 MPa. The results of fitted stress components for NA = 0.70 are σ11/0.70 = −204.46 MPa, σ22/0.70 = 85.42 MPa. The results of fitted stress components for NA = 0.8 are σ11/0.80 = −120.83 MPa, σ22/0.80 = 0 MPa.
Figure 4
Experimental results of sample 1 with different NAs: (a) NA = 0.55, (b) NA = 0.70, (c) NA = 0.80, where black solid points are experimental data points, the red curve is the theoretical result, and the purple curve is the fitted result.
The physical experimental results were given for sample 2 at different NAs in Figure 5. Again, the black solid points are the experimentally measured data points, the red curve is the theoretical result for the stress state, and the purple curve is the fitted result using Equation (7). The fitted curves at three NAs show that the fitted curves follow the same trend as the theoretical curves, but the curves do not overlap. The results of fitted stress components for NA = 0.55 are σ11/0.55 = −16.78 MPa, σ22/0.55 = −42.48 MPa. The results of fitted stress components for NA = 0.70 are σ11/0.70 = −132.61 MPa, σ22/0.70 = 73.96 MPa. The results of fitted stress components for NA = 0.8 are σ11/0.80 = −0.3 MPa, σ22/0.80 = −58.48 MPa.
Figure 5
Experimental results of sample 2 with different NAs: (a) NA = 0.55, (b) NA = 0.70, (c) NA = 0.80, where black solid points are experimental data points, the red curve is the theoretical result, and the purple curve is the fitted result.
Furthermore, the principal stress sum was separately calculated for sample 1 and sample 2 in this paper. The principal stress sums for the experimental results of sample 1 are (σ11 + σ22)0.55 = −112.69 MPa, (σ11 + σ22)0.70 = −119.04 MPa, and (σ11 + σ22)0.80 = −120.83 MPa, respectively. The principal stress sums for the experimental results of sample 2 are (σ11 + σ22)0.55 = −59.26 MPa, (σ11 + σ22)0.70 = −58.68 MPa, (σ11 + σ22)0.80 = −58.78 MPa. The experimental results did not differ much from the sum of the applied principal stresses after the sum of the principal stresses was calculated for these two stress states (as shown in Table 1).The average relative error of stress components and principal stresses sum were calculated based on the experimental results, as shown in Table 3. The average relative error range of the stress components exceeds 43.73% from Table 3. The average relative error is not related to the value of NA, while all relative errors of the principal stress sum are less than 5% from the error distribution.
Table 3
Average relative errors of stress components and principal stress sums in physical experiments.
Sample 1
Sample 2
Average Relative Error of Stress Components
Relative Error of Principal Stress Sums
Average Relative Error of Stress Components
Relative Error of Principal Stress Sums
NA = 0.55
346,100.00%
4.37%
43.73%
0.82%
NA = 0.70
17,882.77%
1.02%
351.43%
0.17%
NA = 0.80
5001.38%
2.54%
98.98%
0%
The large NA cannot be used for decoupling when observing the results of physical experiments. Specifically, an obvious gap remains between the fitted curves and the theoretical curves in most cases (Figure 4b,c and Figure 5a–c), and the fitted curves cannot agree with the theoretical trend because the experimental points are too scattered in a few cases (Figure 4a). The results of all stress components based on the experimental data are significantly different from the actual applied stress state, and there is no indication that the trend is related to the NA of objective lens, which indicates that the use of large-NA lens does not help to decouple stress components. The calculation of the principal stress sum reveals that the proposed method was used to analyse the angle-resolved Raman data in most cases to more accurately identify the principal stress sum, although the experimental points were far from the theoretical curves. Thus, the fitting method can strongly shield single-point errors [36]. However, the relative error of the principal stress sum also exhibits a weak correlation with NA, so the analytical consequences of the principal stress sum are independent of magnitude of NA.The ability of backscattering micro-Raman to probe the sum of principal stresses in {100} c-Si is well known. Using a characterization model that considered NA, refraction and depolarization as in this paper, or a generic model that did not consider NA, refraction and depolarization [18,37], or even the classical method by de Wolf that ignored the effect of shear stress and simplified stress state [23], it is possible and only possible to characterize the principal stresses sum of {100} c-Si using backscattering micro-Raman. Some papers had theoretically concluded that the use of a large-NA objective lens could excite and collect TO mode information and “could” contribute to the decoupling of stress components from {100} c-Si [30]. However, experiments on different stress states using a large-NA objective lens in this paper confirm that the difference in stress components hardly affects the Raman shift, and it is difficult to effectively extract the information of stress components from Raman information. It is impossible to obtain the individual stress components in {100} c-Si unless the relationship between the two principal stresses is predicted, regardless of the NA of the objective lens.K3 is defined as the ratio of the coefficient in front of the principal stress difference to that of the principal stress sum in Equation (7) to clarify the reason for the weak decoupling effect of NA on stress components.K3 was calculated for different NA at different polarization directions and the results (as drawn by Origin in Figure 6) show that the magnitude of NA does correlate with coefficient K3, but the effect is not monotonic. When NA = 0.80, K3 is the maximum value, which is 0.01245. These result shows that the K3 maximum value does not exceed 0.013, which implies that the sum of principal stresses accounts for at least 98.7%, even close to 100%, of the total Raman shift. In other words, the use of large NAs increases the proportion of the principal stress difference in the total Raman shift. However, this proportion is still negligible, which makes it a roadblock to decouple the stress components using a large-NA objective lens. Figure 7 displays the effect of NA on K3 for two common polarization configurations, i.e., the HH-case and HV-case, which are more visually represented by the curves in these two configurations.
Figure 6
Ratio of the coefficient of the principal stress difference to that of the principal stress sum for different NA (K3): (a) NA = 0.28; (b) NA = 0.55; (c) NA = 0.70; (d) NA = 0.80; (e) NA = 0.95; (f) NA = 1.30.
Figure 7
Ratio of the coefficient of the principal stress difference to that of the principal stress sum for different NA (K3): (a) HH-case; (b) HV-case.
The simulation experimental results of stress decoupling are given for six different NA (NA = 0.28, 0.55, 0.70, 0.80, 0.95, 1.30) based on the Raman shift-stress relationship (Equation (7)) to demonstrate the effect of different NA on the stress analysis. The simulation experimental was obtained by substituted the stress state and polarization configuration (HV-case) into Equation (7) and then drawn the Raman shift-polarization direction curves. The stress states were chosen as biaxial (σ11 = σ22 = −500 MPa) and unequal biaxial (σ11 = −700 MPa, σ22 = −300 MPa). The two stress states have identical principal stress sums, and the stress components are large (exceeding the compressive strength) and will be difficult to achieve in physical experiments due to sample breakage.The results of the simulation experiments are shown in Figure 8. The solid dots indicate the corresponding Raman shifts in different polarization directions, and the solid lines indicate the fitted curves of the dots. Red, orange, green, blue, purple and black correspond to NAs of 0.28, 0.55, 0.70, 0.80, 0.95 and 1.30, respectively. The polarization direction-Raman shift curves are basically identical for different stress states with identical NAs although the two stress states are different, as shown in Figure 8a,b.
Figure 8
Simulation experiment of (a) biaxial (σ11 = σ22 = −500 MPa) and (b) unequal biaxial (σ11 = −700 MPa, σ22 = −300 MPa) stress states at different NA.
The difference of the respective Raman shifts was taken at six different NAs, i.e., the curve of Figure 8b was subtracted from the curve of Figure 8a for identical NAs, and the result is shown in Figure 9a. The maximum value of the difference in Raman shifts does not exceed 0.009 cm−1 from Figure 9a. Such a small Raman shift difference occurs at a large magnitude of stress, which is difficult to distinguish for existing Raman spectroscopy instrument systems. In general, advanced research-grade Raman spectroscopy systems can achieve a spectral resolution of 0.1 cm−1. Ideally, the spectral repeatability of a c-Si for calibration is up to ±0.015 cm−1. The range of systematic random error significantly exceeds the above range due to environmental, operational and other factors in practice. Thus, the difference in Raman shifts due to the difference in stress state is much smaller than the random error of the system, which results in its nonrecognition. Furthermore, the main factors that may cause errors also include random polarization errors in angle-resolved Raman experiments. The random errors of the polarization directions of less than ±1° and the systematic random errors of less than ±0.02 cm−1 were introduced in the simulation experiments using the experimental error introduced method by Qiu et al. [38]. The difference in Raman shifts was derived from two different stress states under the same polarization state as in Figure 9b. Figure 9b shows that the distribution of the difference in Raman shifts does not have any pattern, and the maximum is close to 0.05 cm−1 after the error is introduced. These haphazard Raman shift differences are not caused by variability with stress state but are caused by introducing two measurement errors. Thus, it is difficult for the current micro-Raman instrument to identify the difference in stress states and decouple the stress components in the case of identical principal stress sums.
Figure 9
Difference in Raman shifts of the unequal biaxial and biaxial stress states of (a) theoretical and (b) introducing the random error in polarization direction and system.
Accurate characterization of stresses in c-Si of {100} family of crystal planes is imperative for the semiconductor industry and related research. The work in this paper demonstrates that the use of large-NA objective lens does not contribute to the decoupling analysis of stress components. Fu et al. proposed a method using oblique scattering for stress analysis, which can effectively excite and collect information from the transverse optical phonon mode and achieve in-plane stress component decoupling [20].
5. Conclusions
In recently several published works by others claimed that the stress/strain states of {100} c-Si were or could be decoupled through MRS with large numerical aperture (NA) lenses. In this paper, for the stress components decoupled from {100} c-Si, angle-resolved Raman experiments using different NA objectives were compared based on a theoretical model for different stress states by combining physical and simulation experiments. It was proven that decoupling analysis of stress components using any large-NA objective lacked practicability:The backscattering Raman can give a relatively accurate sum of the principal stresses in {100} c-Si, regardless of the NA size. However, decoupling analysis of the in-plane stress components cannot be achieved.This work finds that the principal stress sum is more than 98.7% of the total Raman shift, which is close to 100% by analysing the theoretical model and simulation experiment results. The principal stress difference part, which can represent the variability of stress state, has a subtle weight in the total Raman shift.The Raman shift variation caused by stress state is much smaller than the resolution of existing micro-Raman system, which cannot be identified in the experimental results with the combination of various experimental errors.These factors ultimately lead to the lack of realistic value of utilizing large-NA objective lens to perform the stress component decoupling analysis.