Bedside ultrasonic localization of the nasogastric tube in a patient with severe COVID-19: A case report.

Xiao-Ju Zhu1, Shui-Xia Liu1, Qiu-Tang Li2, Yuan-Jing Jiang3.   

Abstract

BACKGROUND: The indwelling nasogastric tube is commonly used for supplying enteral nutrition to patients who are unable to feed themselves, and accurate positioning is essential in the indwelling nasogastric tube in the body of the aforementioned patients. In clinical practice, abdominal radiography, auscultation, and clinical determination of the pH of the gastric juice are routinely used by medical personnel to determine the position of the tube; however, those treatments have proved limitations in specific cases. There are few case reports on the precise positioning of the nasogastric tube in patients with coronavirus disease 2019 (COVID-19), for whom a supply of necessary nutrition support is significant throughout the process of treatment. CASE
SUMMARY: A 79-year-old patient, diagnosed with COVID-19 at the stage of combined syndromes with severe bacterial lung infection, respiratory failure, multiple co-morbidities, and a poor nutritional status, was presented to us and required an indwelling nasogastric tube for enteral nutrition support. After pre-treatment assessments including observation of the patient's nasal feeding status and examination of the nasal septal deviation, inflammation, obstruction, nasal leakage of cerebrospinal fluid, and other disorders that might render intubation inappropriate, we measured and marked the length of the nasogastric tube to be placed and delivered the tube to the intended length in the standard manner. Then further scrutiny was conducted to ensure that the tube was not coiled in the mouth, and gentle movements were made to avoid damage to the esophageal mucosa. However, back draw of the gastric juice using an empty needle failed, and the stethoscope could not be used for auscultation due to the specific condition presented by the internal organs of the patient, and the end of the tube was placed in saline with no bubbles spilling out. Therefore, it was not possible to determine whether the nasogastric tube was placed exactly in the stomach and no nutrient infusion was performed for the time being. Subsequently, the ultrasound probe was utilized to view the condition of the patient's stomach, where the nasogastric tube was found to be translucent and running parallel to the esophagus shaped as "=". The pre-conditions were achieved and 100 mL nutritional fluid was fed to the patient, who did not experience any discomfort throughout the procedure. His vital signs were stable with no adverse effects.
CONCLUSION: We achieved successfully used ultrasound to position the nasogastric tube in a 79-year-old patient with COVID-19. The repeatable ultrasound application does not involve radiation and causes less disturbance in the neck, making it advantageous for rapid positioning of the nasogastric tube and worthy of clinical promotion and application. ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved.

Entities:  

Keywords:  COVID-19; Case report; Localization; Nasogastric tube; Nutrition supply; Ultrasound

Year:  2022        PMID: 35801030      PMCID: PMC9198854          DOI: 10.12998/wjcc.v10.i15.4911

Source DB:  PubMed          Journal:  World J Clin Cases        ISSN: 2307-8960            Impact factor:   1.534


Core Tip: External nutrition supply via nasogastric tube is crucial for patients who are unable to feed themselves to sustain physical functions. The traditional methods of indwelling nasogastric tube in a patient’s body has limitations in medical treatment. Herein, we present a rare case of application of ultrasonic localization of a nasogastric tube in a patient with coronavirus disease 2019, in whom traditional methods failed to indicate successful indwelling. This case highlights the importance of appropriate application of ultrasonic localization as a supplementary method to ensure that the nasogastric tube has been properly placed in the patient’s stomach.

INTRODUCTION

Coronavirus disease 2019 (COVID-19) is a novel acute respiratory infectious disease caused by severe acute respiratory syndrome coronavirus 2. COVID-19 is characterized by a rapid rate of transmission and susceptibility of the population. The disease usually manifests with symptoms of fever, dry cough, and fatigue. In severe cases, patients may experience dyspnea and/or hypoxemia in the week following onset. Severe COVID-19 can rapidly progress to acute respiratory distress syndrome, septic shock, irreversible metabolic acidosis, coagulation dysfunction, and multiple organ failure[1-2]. Due to reduced food intake, increased energy consumption, and impaired anabolic functioning, the incidence of malnutrition in these patients can reach 25% to 65%[3], and may adversely affect patient outcomes. Early enteral nutrition is considered one of the active treatment measures for critically ill patients as it can reduce the severity of the disease and the incidence of complications, as well as shorten hospitalization and improve patient prognosis[4-6]. The indwelling nasogastric tube is the most commonly used method for supplying enteral nutrition. The tube requires accurate positioning. Traditional methods include extraction and examination of the patient’s gastric juice, followed by determination of the sound of air passing through the liquid. The tube can also be positioned via using ultrasound and X-rays. Under COVID-19 and Level 3 protection requirements, the use of bedside ultrasound is advantageous in situations where the stethoscope cannot be used, and it does not require extensive human and material resources.

CASE PRESENTATION

Chief complaints

A 79-year-old patient was admitted to the Department of Critical Care Medicine, the COVID-19 Specialist Hospital of Wuhan Taikang Tongji Hospital (Wuhan, China), with severe COVID-19, coronary atherosclerotic heart disease, and cerebral infarction in March 2020.

History of present illness

The patient had developed fever without obvious inducement 7 wk prior, with a body temperature reaching 38.5 °C, fatigue and anorexia. The body temperature then fluctuated between 36.5 °C and 38 °C. Since the onset of the disease, the patient had had no contact with COVID-19 patients. At the time of admission, the patient was severely ill, complicated by pulmonary bacterial infection, respiratory failure, co-morbid diseases, and poor nutrition. The patient required a nasogastric tube for enteral nutritional support, which was inserted in the hospital under medical supervision.

History of past illness

The patient had a history of cerebral infarction and recovered through drug treatment without obvious impairment of either action or speech.

Personal and family history

There was no history of COVID-19 or other medical issues in the patient‘s family.

Physical examination

On arrival in the department, the nutritional status of the patient and the feasibility of nasal feeding of the patient were assessed. In addition, the patient was investigated for nasal septum deviation, nasal inflammation, obstruction, cerebrospinal fluid rhinorrhea, and other conditions that would render indwelling unsuitable.

Laboratory examinations

After admission, laboratory examinations were conducted and the patient received anti-infection and antiviral treatment, together with treatments for improving cardiac function, blood transfusions, and other symptomatic treatments.

Imaging examinations

An initial imaging evaluation with brain computed tomography (CT) scan suggested multiple small punctate hypodense foci next to the lateral ventricles bilaterally, with ischemic changes and a high probability of acute ischemic stroke; the chest CT revealed scattered patches and cloudy fuzzy shadows in both lungs, and the patient was considered to have been infected with COVID-19.

FINAL DIAGNOSIS

The patient was severely ill, complicated by pulmonary bacterial infection, respiratory failure, co-morbid diseases, and poor nutrition. The patient required a nasogastric tube for enteral nutritional support.

TREATMENT

The required length of the nasogastric tube was determined and marked during physical examination. Then the tube was inserted to the predetermined length by the routine procedure. The nasogastric tube was gently placed to avoid damaging the esophageal mucosa and to ensure that the tube was not coiled in the mouth.

OUTCOME AND FOLLOW-UP

The gastric juice was not able to be extracted using an empty needle. Meanwhile, due to the particular circumstances, the stethoscope could not be used for auscultation. The end of the nasogastric tube was placed in normal saline solution without bubble overflow. As a result, it was unknown whether the tube was in the stomach, and no nutrient solution was injected. The tube position was then examined via ultrasound. The ultrasonic probe could clearly identify the circular nasogastric tube and comet tail sign through the cross-section after the esophageal inlet. On examination of the longitudinal section of the esophagus, it was observed that the nasogastric tube was running parallel in the esophagus, seen as two parallel transparent hyperechoic images in the shape of “=” (Figure 1). This indicated the position of the nasogastric tube, and then 100 mL nutrient solution was injected. The patient suffered no discomfort and the vital signs were stable without adverse reactions.
Figure 1

Circular nasogastric tube and comet tail sign through the cross-section after the esophageal inlet.

Circular nasogastric tube and comet tail sign through the cross-section after the esophageal inlet.

DISCUSSION

Routine diagnostic methods

Conventional auscultation: Conventionally, a stethoscope with a 50 mL disposable syringe is used for auscultation. Initially, 20 to 30 mL of air is rapidly injected, followed by repeated auscultation in the abdomen. Detection of a high-profile sound of air passing through the liquid indicates that the tube is located in the stomach. Extraction of gastric juice: A sterile syringe is connected to the end of the tube to determine whether gastric juice can be extracted. Overflowing bubbles: The end of the tube is placed in a bowl filled with cold boiled water or normal saline to determine the presence of bubbles. Plain X-ray abdominal radiograph examination: A bedside X-ray film is taken within 2 h after insertion of the nasogastric tube, and mobile digital radiography is performed. The radiologist obtains anterior-posterior chest images according to the specifications and completes the film reading and the report. Ultrasonic localization: The gas status in the patient's stomach should be identified. If a strong echo appears with too much gas, this may affect the judgment of the result. Thus, it is necessary to extract the gas before exploration. After inserting the nasogastric tube, the circular tube and the comet tail sign were clearly seen in the transverse section after the ultrasonic probe passed through the esophageal inlet. In the longitudinal section, the nasogastric tube was found to run parallel in the esophagus, seen as two parallel transparent hyperechoic images in the shape of “=”.

Disadvantages of conventional diagnostic methods and advantages of ultrasound diagnosis

Auscultation: When air is injected into the nasogastric tube, the sound of air passing through liquid is strongly discernable on auscultation. The sound of air injected into the trachea and pleural cavity is not easy to distinguish from that injected into the stomach. Therefore, it is not easy to accurately distinguish the location of the nasogastric tube by auscultation, and some patients may present with clinical manifestations such as choking and decreased oxygen saturation[7]. Given that COVID-19 is a Class B infectious disease and can be transmitted by contact and droplets, medical personnel need Level 3 protection when entering the Red zone to reduce the risk of infection. Additionally, a stethoscope used in the Red zone becomes a contaminated object, and viruses and other pollutants may attach to the surface. Because of this, the stethoscope should not come into direct contact with the body surface of the medical personnel. In addition, the senses, including sensation in the limbs, and especially hearing, are greatly weakened, which adversely affect the accuracy of judgment and auscultation. Therefore, conventional auscultation in patients with COVID-19 increases the risk of exposure of medical personnel to the virus and is also difficult to implement. Extraction of gastric juice: Clinically, we found that most critical patients with COVID-19 are unable to eat. After insertion of the nasogastric tube, adhesion and reverse folding of the tube may occur, resulting in too little liquid in the stomach. As a result, it is impossible to locate and extract the nasogastric contents accurately, thus limiting the efficacy of the gastric juice extraction method. Bubble overflow method: The end of the tube is placed in a bowl filled with normal saline to determine overflow of the bubbles. However, bubble overflow may only indicate that the tube is in the airway and is not able to detect whether it is in the stomach. It is also not recommended for routine use as it may increase the risk of inadvertent aspiration when the patient is aspirating[8]. Plain abdominal X-ray examination: The determination of nasogastric tube positioning by bedside radiography is the gold standard for determining accurate positioning; however, this has the disadvantages of high levels of radiation and the length of the procedure, making it unsuitable for repeated use[9-10]. In addition, with COVID-19, all medical personnel are required to use Grade 3 protection, and the removal of instruments from the radiology department not only increases the workload for the radiology personnel but also affects the timing and efficiency of the treatment. Also, when performing abdominal plain X-rays for severely ill patients, usually at least three medical personnel are required to move and place the body in position, resulting in increased physical exertion. Furthermore, when moving, the radius of action would tend to increase, as would the amount of perspiration from the medical personnel, which would tend to reduce the effectiveness of the protective clothing and thus increase the risk of exposure. For patients with severe disease, there are usually many tubes attached. The risk of tube slippage would increase and thus the quality of nursing would tend to be reduced during movement. Ultrasonic localization: Studies have reported a 100% accuracy rate of bedside ultrasound in determining the success of gastric tube placement[11].Ultrasound is a non-invasive procedure with the advantages of repeatability and a lack of radiation[12]. For unconscious patients, bedside ultrasound positioning is safe and can be carried out with other diagnostic and treatment measures without affecting mechanical ventilation, delaying treatment, and transferring risk. Furthermore, bedside ultrasound has been reported to intuitively indicate the patient's condition and pathology, improve the precision of clinical diagnosis, guide the positioning of intubation and puncture operation and therefore reduces damage to the laryngeal mucosa caused by repeated manipulation[13]. Moreover, given its intuitive, fast, accurate, and convenient features, bedside ultrasound has been applied as a standard tool for monitoring and evaluating severely ill patients and positioning of punctures in intensive care unit, anesthesia, and emergency departments in numerous countries[14-16]. It is not difficult to locate the position of the nasogastric tube if the thyroid and tracheal positions are located. In addition, there is less disturbance to the neck. If the position of the nasogastric tube cannot be determined due to pseudo-interference or other causes, about 20 mL of air should be quickly injected into the tube. This would result in the formation of a prominent gas reflection plane, and the position of the tube would be visible as a strong strip echo under ultrasound. The intensive care unit of our department has an ultrasound machine to reduce the increased workload caused by repeated demand. This instrument is always available to facilitate the timely diagnosis and treatment of patients.

CONCLUSION

Accurate positioning of the nasogastric tube in severely ill patients with COVID-19 using bedside ultrasound could reduce both the risk of viral exposure to medical personnel and the clinical workload, as well as avoid X-ray radiation. Bedside ultrasound localization of the nasogastric tube produces immediate accurate results, thus gaining valuable time for clinical treatment and effectively improving both the potential success of the treatment and prognosis of the patient. It is thus worthy of clinical promotion and application.

ACKNOWLEDGEMENTS

The authors would like to thank the patient and his family for their cooperation in relation to this case report.
  15 in total

Review 1.  Devices and techniques for bedside enteral feeding tube placement.

Authors:  Susan Roberts; Pamela Echeverria; Sabrey A Gabriel
Journal:  Nutr Clin Pract       Date:  2007-08       Impact factor: 3.080

2.  Altered balance of the aminogram in patients with sepsis - the relation to mortality.

Authors:  Tomoya Hirose; Kentaro Shimizu; Hiroshi Ogura; Osamu Tasaki; Toshimitsu Hamasaki; Shuhei Yamano; Mitsuo Ohnishi; Yasuyuki Kuwagata; Takeshi Shimazu
Journal:  Clin Nutr       Date:  2013-12-14       Impact factor: 7.324

3.  Point-of-care ultrasound for peripherally inserted central catheter monitoring: a pilot study.

Authors:  Patrick Motz; Amelie Von Saint Andre Von Arnim; Ramesh S Iyer; Shilpi Chabra; Maggie Likes; Manjiri Dighe
Journal:  J Perinat Med       Date:  2019-11-26       Impact factor: 1.901

Review 4.  Fluid administration limited by lung sonography: the place of lung ultrasound in assessment of acute circulatory failure (the FALLS-protocol).

Authors:  Daniel Lichtenstein
Journal:  Expert Rev Respir Med       Date:  2012-04       Impact factor: 3.772

5.  Dynamic anatomic relationship of the esophagus and trachea on sonography: implications for endotracheal tube confirmation in children.

Authors:  James W Tsung; Daniel Fenster; David O Kessler; Joseph Novik
Journal:  J Ultrasound Med       Date:  2012-09       Impact factor: 2.153

6.  The burden of diarrhea in the intensive care unit (ICU-BD). A survey and observational study of the caregivers' opinions and workload.

Authors:  Claudia-Paula Heidegger; Séverine Graf; Thomas Perneger; Laurence Genton; Taku Oshima; Claude Pichard
Journal:  Int J Nurs Stud       Date:  2016-04-20       Impact factor: 5.837

Review 7.  Lung ultrasound: a promising tool to monitor ventilator-associated pneumonia in critically ill patients.

Authors:  Guyi Wang; Xiaoying Ji; Yongshan Xu; Xudong Xiang
Journal:  Crit Care       Date:  2016-10-27       Impact factor: 9.097

8.  Plasma metabolomics of early parenteral nutrition followed with enteral nutrition in pancreatic surgery patients.

Authors:  Zhengyu Jiang; Cen Wen; Changli Wang; Zhenzhen Zhao; Lulong Bo; Xiaojian Wan; Xiaoming Deng
Journal:  Sci Rep       Date:  2019-12-11       Impact factor: 4.379

9.  Characteristics of and Important Lessons From the Coronavirus Disease 2019 (COVID-19) Outbreak in China: Summary of a Report of 72 314 Cases From the Chinese Center for Disease Control and Prevention.

Authors:  Zunyou Wu; Jennifer M McGoogan
Journal:  JAMA       Date:  2020-04-07       Impact factor: 56.272

10.  Effect of early enteral nutrition support for the management of acute severe pancreatitis: A protocol of systematic review.

Authors:  Yong-Bo Guo; Yan Liu; Jing Ma; Ying Cai; Xiao-Ming Jiang; Hong Zhang
Journal:  Medicine (Baltimore)       Date:  2020-08-07       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.