| Literature DB >> 35799056 |
Yanjun Xiao1, Kun Zhang2, Yameng Zhang2, Wei Zhou2, Weiling Liu2, Feng Wan3.
Abstract
The recovery of low-quality waste heat is a major problem in energy utilization. In order to solve this problem and improve energy utilization, the research group designed a low-quality waste heat power generation device with Roots power machine as the core. However, the device has poor ability to adjust the rotation speed and it is difficult to generate electricity stably. The fundamental reason is that the system has many variables and strong coupling. According to the actual working conditions, the power of the device is 10 kW, and the fluctuation range should be within ± 7%. On the one hand, it can be improved by hardware, on the other hand, the design of software is also very critical. At present, through the investigation of domestic and foreign researches on the control system, it is found that the stability of the system is gradually improved, but the problem of strong coupling between variables has not been effectively solved. Therefore, the research group modeled the variables in the system and obtained a coupled model. Based on the couple model, the research group introduced nonlinear multi-model adaptive closed-loop decoupling control and designed a control system. The simulation results show that the maximum overshoot of the control system is 3.9%, the adjustment time is also reduced, and it is stable in low quality waste heat recovery device. Experimental results show that under the control of the system, the rotational speed of roots motor can keep stable, the maximum deviation is not more than 21.4 r/min, and the fluctuation range is within ± 7%, which meets the requirements of the index. This has laid the foundation for the follow-up research of grid-connected power generation.Entities:
Year: 2022 PMID: 35799056 PMCID: PMC9262922 DOI: 10.1038/s41598-022-15808-0
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.996
Figure 1Distribution and reuse of waste heat resources.
Figure 2Low-quality waste heat recovery and utilization device with roots power machine as the core.
Figure 3Roots waste heat recovery power generation device.
Operating condition parameters of Roots waste heat power generation device.
| Parameter index | Numerical range |
|---|---|
| Rated power (kW) | 10 |
| Intake pressure (MPa) | 0.2–1.0 |
| Air source temperature (℃) | 80–160 |
| Output allowable fluctuation | ± 7% |
Figure 4Variable coupling diagram of Roots waste heat power generation system.
Figure 5Flow characteristic curve of valve.
Figure 6Block diagram of electric actuator.
Figure 7Curve of tracking performance.
Tracking performance.
| Performance | Decoupling control | PID control |
|---|---|---|
| Overshoot | 3.9% | 8% |
| Adjustment time | 66s | 70s |
Figure 8The overall structure of the experimental platform.
Figure 9The connection of the control system.
Figure 10Gas source.
Figure 11Speed deviation contrast curve.
Track performance data.
| Serial number | Desired speed (r/min) | Decoupling control | PID control |
|---|---|---|---|