Literature DB >> 35797373

The influence of receiving real-time visual feedback on breathing during treadmill running to exhaustion.

Joseph A Passafiume1, Nelson A Glover1, Anne R Crecelius2, Ajit M W Chaudhari1,3,4.   

Abstract

Breathing plays a vital role in everyday life, and specifically during exercise it provides working muscles with the oxygen necessary for optimal performance. Respiratory inductance plethysmography (RIP) monitors breathing through elastic belts around the chest and abdomen, with efficient breathing defined by synchronous chest and abdomen movement. This study examined if providing runners with visual feedback through RIP could increase breathing efficiency and thereby time to exhaustion. Thirteen recreational runners (8F, 5M) ran to exhaustion on an inclined treadmill on two days, with visual feedback provided on one randomly chosen day. Phase angle was calculated as a measure of thoraco-abdominal coordination. Time to exhaustion was not significantly increased when visual feedback was provided (p = 1). Phase angle was not significantly predicted by visual feedback (p = 0.667). Six participants improved phase angle when visual feedback was provided, four of whom increased time to exhaustion. Four participants improved phase angle by 9° or more, three of whom increased time to exhaustion. Participants who improved phase angle with visual feedback highlight that improving phase angle could increase time to exhaustion. Greater familiarization with breathing techniques and visual feedback and a different paradigm to induce running fatigue are needed to support future studies of breathing in runners.

Entities:  

Mesh:

Year:  2022        PMID: 35797373      PMCID: PMC9262203          DOI: 10.1371/journal.pone.0270335

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.752


Introduction

Running has been established as one of the most popular forms of physical activity in the United States for several years [1]. Running, like any form of exercise, has metabolic requirements that the body must meet, and a primary way that the body meets these requirements is through breathing [2]. Breathing allows for the exchange of oxygen and carbon dioxide between the lungs and blood, and the heart pumps oxygen-carrying red blood cells to the working muscles for fuel, which allows muscle contractions to continue through the production of adenosine triphosphate via the metabolic pathways of glycolysis and mitochondrial respiration [3-6]. Through maximum oxygen uptake testing, it is known that those who are better at exchanging oxygen with the body can perform endurance exercise for longer periods of time [7, 8]. The most efficient breathing entails the chest and abdomen expanding and contracting in synchrony, which allows for no interference with the contracting diaphragm and maximal air intake into the lungs, therefore maximizing the amount of oxygen going into the bloodstream with each breath [9-12]. The breathing technique of the chest and abdomen expanding and contracting in synchrony has been implemented in various settings previously, which ultimately showed improved oxygen intake in a population of participants with chronic obstructive pulmonary disease [9] as well as reduced oxidative stress in the bloodstream following exhaustive exercise [10]. Furthermore, on breathing in general during exercise, tidal volume has been shown to be relevant to exertion level and maximal oxygen uptake [11], and individuals with more synchronous chest and abdomen movements during a graded run experienced less oxygen desaturation [12]. Combining these aspects of efficient breathing and breathing during exercise, improving breathing patterns during exercise could lead to performance improvements through improved oxygen exchange. This efficient breathing can be measured and displayed in real time using respiratory inductance plethysmography (RIP) [13-16], creating an opportunity to use RIP for biofeedback training. RIP is a non-invasive method of monitoring breathing through the placement of elastic belts around the chest and abdomen, referred to as RIP belts, that vary their voltage outputs as their circumference changes [17]. RIP has been shown to be reliable and accurate when compared to other measurements of breathing at rest [18, 19] and during exercise [20-24]. While there have been studies that have attempted to alter breathing pattern during exercise [25-27], there are no studies that have investigated if optimizing breathing patterns can improve running performance. Breathing for chest and abdomen synchronicity has been taught previously [28] but has not been applied in sport-based research. Synchrony between the chest and abdomen is quantified through the absolute value of the phase angle [20, 22, 29]. Phase angle values range from 0–180°, where a value of 0° signifies perfectly synchronous movement of the chest and abdomen, shown in Fig 1. Common phase angle values of humans range from 0–24° at rest [13] and average out to approximately 20° during exercise to exhaustion [20].
Fig 1

Chest and abdomen plots during a single breath.

Reproduced from Sivan et al. [13]. Sample phase angles from chest (RC) and abdomen (ABD) data for three different single breaths: synchronous, asynchronous, and paradoxical. The variable m is the distance between the intercepts of the chest and abdomen loop with a horizontal line halfway between the minimum and maximum chest excursions, while the variable s is the maximum abdomen excursion. Phase angle is then calculated by taking the inverse sine of m/s, with the values always ranging between 0 and 180 degrees. Perfectly synchronous breathing is signified by a value of zero degrees.

Chest and abdomen plots during a single breath.

Reproduced from Sivan et al. [13]. Sample phase angles from chest (RC) and abdomen (ABD) data for three different single breaths: synchronous, asynchronous, and paradoxical. The variable m is the distance between the intercepts of the chest and abdomen loop with a horizontal line halfway between the minimum and maximum chest excursions, while the variable s is the maximum abdomen excursion. Phase angle is then calculated by taking the inverse sine of m/s, with the values always ranging between 0 and 180 degrees. Perfectly synchronous breathing is signified by a value of zero degrees. Given that the body relies on breathing to carry out physical demands and that breathing in healthy individuals is typically not optimally efficient while at rest or exercising [12, 13], this study sought to examine if time to exhaustion of runners using an inclined graded running paradigm could be increased if real-time visual feedback on the breathing pattern of the chest and abdomen was provided during an exhaustive run. It was hypothesized that having visual feedback during the run would improve breathing efficiency, in turn leading to an increased time to exhaustion.

Materials and methods

Participant population

Thirteen adult recreational runners (eight females, five males) participated in this study, with recreational runners defined as those who run eight to thirty-two kilometers per week on average. Participant demographics are provided in Table 1. All participants did not have a previous lower limb surgery, medically diagnosed breathing deficiency, nor a running related injury in the past six months [30]. All participants filled out an initial contact survey to ensure the previously mentioned criteria were met. The methods of this study were approved by the Biomedical Institutional Review Board at The Ohio State University (approval number 2019H0183) and all participants provided written informed consent prior to beginning the study.
Table 1

Participant demographics.

ParticipantSex (M/F)Age (years)Height (cm)Weight (kg)Self-Reported Average km Run per WeekDays between Testing Visits
1F1916556147
2M22183791019
3M24189822739
4F28173671014
5F4116471328
6F2217061830
7F35168702435
8M2218391267
9M21175642616
10F2416350197
11F2317078327
12F20170601314
13M31177731612
Mean -25.5173.069.419.816.5
SD -6.58.111.48.611.2

Testing overview

Participants were brought to the laboratory on two separate days for testing. The testing days were separated by at least one week and participants were instructed to refrain from exercise within twenty-four hours of testing times to avoid possible impacts on testing day performance [23, 31–33]. All participants were instructed to wear comfortable running attire and the same self-provided shoes for both testing days. The desired sample size for this study was estimated at fifteen participants, based on similar research involving exercise across multiple testing days that ultimately reported significant differences in performance due to dietary supplements [31, 33–36]. Of these studies, three specifically involved exercise to exhaustion [34-36] and the largest sample size was twelve [34]. On both testing days, participants completed a graded treadmill fatigue protocol to voluntary exhaustion [36]. On one of these testing days, real-time visual feedback on chest and abdomen expansion was provided to the participant during the run. Block randomization was used to ensure an even split of visual feedback on the first and second testing visits across the entire population. All running was performed on a Bertec split-belt instrumented treadmill (Bertec Corp., Columbus, OH).

Visual feedback animations

A visual feedback interface was created in LabVIEW, consisting of two sets of images that were animated in sequence based on the voltage outputs from the RIP belts. Each set of images was independently controlled by its corresponding RIP belt. The chest was represented by an umbrella and the abdomen was represented by a rose, shown in Fig 2. The umbrella and rose were selected at the suggestion of a physical therapist, as they are common objects that can easily be interpreted by participants when wearing the RIP belts. A twenty-inch computer monitor was mounted to the front of the treadmill to provide feedback on the needed testing day, shown in Fig 3.
Fig 2

Visual representation of the abdomen and chest animations.

The abdomen is represented by the rose and the chest is represented by the umbrella with each being independently controlled by the respective RIP belt. A change in the circumference of a belt results in a change in the voltage being output by the belt. The animations were programmed to change images based on these changes in voltage outputs. The actual animations contained 194 images for the rose and 156 images for the umbrella over the range of possible voltages.

Fig 3

Treadmill display.

The monitor mounted to the front of the treadmill that displayed the animations for real-time visual feedback.

Visual representation of the abdomen and chest animations.

The abdomen is represented by the rose and the chest is represented by the umbrella with each being independently controlled by the respective RIP belt. A change in the circumference of a belt results in a change in the voltage being output by the belt. The animations were programmed to change images based on these changes in voltage outputs. The actual animations contained 194 images for the rose and 156 images for the umbrella over the range of possible voltages.

Treadmill display.

The monitor mounted to the front of the treadmill that displayed the animations for real-time visual feedback.

Treadmill fatigue protocol

The treadmill fatigue protocol entailed setting the treadmill to a fixed three-degree incline with a starting speed of 2.25 m/s. Every minute, the treadmill would increase speed by 0.0833 m/s with an acceleration of 0.25 m/s2. At the fifty-eighth second of every minute, a two-second beep would occur to notify the participant that the treadmill speed was about to increase. This protocol was selected based on similar research involving a running population undergoing treadmill testing to exhaustion [36] and to ensure that this wide-ranging population of runners all reached a true exhaustion point rather than simply not being able to move their legs fast enough to keep pace with the treadmill. An additional LabVIEW program was created to control the treadmill, which included automated speed changes and audible alerts. Prior to undergoing the treadmill fatigue protocol at a three-degree incline on each testing day, participants ran a five-minute warmup on the treadmill at a self-selected speed with no incline. The treadmill warmup speed was the same on both testing days for each participant. No visual feedback on breathing nor instruction for breathing were provided prior to the five-minute warmup. One-minute of rest followed this warmup.

Breathing instructions for participants during the fatiguing run

Participants were provided with breathing information during the one-minute of rest after the warmup for the upcoming run to exhaustion. On both testing days, participants were told that the most efficient breathing entails the chest and abdomen expanding and contracting in synchrony and to try to exhibit this breathing pattern during the entire run. If the testing day did not include visual feedback, only this verbal explanation was provided. If the testing day included visual feedback, the visual feedback animations being displayed on the monitor were explained. Any questions the participant had pertaining to breathing or the animations were answered before beginning the fatigue protocol. Participants were instructed to run to volitional exhaustion and to signal to the research team when this point was reached so the treadmill could be stopped.

Equipment placement

Equipment placed on participants for all running tasks included two RIP belts placed around the chest and abdomen, a neoprene belt containing the data collection unit, a heart rate monitor, and a safety harness, shown in Fig 4. The RIP belts were consistently placed on the participant with the chest belt at the level of the xyphoid process and below the pectoral muscles, and the abdomen belt at the level of the navel, as previous RIP research has prescribed [37, 38]. A neoprene belt with hook and loop fabric covering (CoreX Therapy, Perfect Practice, Inc.) was placed at the level of the waist to house the additional equipment needed for RIP, which included a BioRadio and two interface cables (Great Lakes NeuroTechnologies, Cleveland, OH). A Polar H7 heart rate monitor (Polar Electro Inc., Bethpage, NY) was placed on bare skin between the previously mentioned RIP belts. Each participant was fit with a custom-made harness [39] composed of two hammock straps (ENO Suspension, Asheville, NC) to prevent an injurious fall should they lose their footing.
Fig 4

Equipment worn by participants.

Anterior and posterior view of the equipment worn by participants while running. This equipment included two RIP belts, a heart rate monitor, a harness, and a neoprene belt. The neoprene belt housed the BioRadio, which was used to detect changes in voltage outputs of the belts, and additionally was where excess wiring from the RIP belts to the BioRadio was held down.

Equipment worn by participants.

Anterior and posterior view of the equipment worn by participants while running. This equipment included two RIP belts, a heart rate monitor, a harness, and a neoprene belt. The neoprene belt housed the BioRadio, which was used to detect changes in voltage outputs of the belts, and additionally was where excess wiring from the RIP belts to the BioRadio was held down.

Data collection and processing

Breathing data were collected during the five-minute warmup and the fatigue protocol at 250 Hz. VivoSense version 3.3 (VivoSense, Newport Coast, CA) was used to filter and analyze the breathing data, which has been commonly used in exercise research with RIP [20-23]. Fig 5 illustrates the data processing steps automatically performed by VivoSense [14, 40, 41] to calculate the phase angle on a breath-by-breath basis for a typical breath in this dataset. A low-pass Butterworth filter (1.4 Hz cutoff) was applied to the breathing data, which has been shown to remove signal values that were generated from causes outside of breathing [23]. Voltages were converted to volumes for the chest and abdomen using a standard calibration algorithm, and the calibration weights the abdomen and chest bands with equal unit weighting. The tidal volume is calculated as the sum of each filtered and scaled chest and abdomen point over time, thus forming another sinusoidal wave. Tidal, chest, and abdomen volumes are then proportionately scaled so that the average tidal volume over the entire testing session is 400mL. Detection of the beginning of inhalation for each breath was performed by (a) detecting the first incidence of a positive slope in the tidal volume, and (b) checking that the peak-to-trough change from the previous beginning of inhalation was greater than 48mL [41], also known as breath reversal detection. Once each breath, i.e. the interval from one beginning of inhalation to the next, had been identified, the phase angle for each breath could be calculated, as explained in Fig 1. These computations assume that chest and abdomen excursions are sinusoidal, so the filtered and calibrated chest and abdomen data form a loop (Fig 5, bottom). Breath-by-breath phase angle values were then averaged over the entire duration of the specific run of interest. Thus, three average phase angle values were calculated for each participant: warmup, run to exhaustion with visual feedback, and run to exhaustion without visual feedback.
Fig 5

The process used by VivoSense to calculate phase angle for each breath.

The entire process undergone by raw chest and abdomen data to calculate phase angle for a single breath.

The process used by VivoSense to calculate phase angle for each breath.

The entire process undergone by raw chest and abdomen data to calculate phase angle for a single breath. Time to exhaustion was defined as the duration of the fatigue protocol from the beginning of the inclined run to volitional exhaustion. Heart rate beats per minute (BPM) data were output and recorded every minute during the fatigue protocol via the Polar Beat: Run & Fitness iOS application.

Statistical analyses

For consistency across all variables of interest, univariate regression analyses were used to identify significant relationships for all continuous and logistic variables. Pairwise Pearson correlation coefficients were calculated for the variables of time to exhaustion, phase angle, warmup phase angle, age, sex, height, weight, a participant’s kilometers run per week, days between testing periods, testing visit, and whether visual feedback was provided. Univariate linear regressions were performed for the dependent variables of time to exhaustion and phase angle using the variables listed previously as predictors. Statistical significance was set a priori at α = 0.05. No correction for multiple comparisons was performed due to the exploratory nature of this study. All statistical analyses were performed in SPSS version 26 (IBM, Armonk, NY).

Results

Phase angle and time to exhaustion

Table 2 provides phase angle and time to exhaustion values for all participants during the runs to exhaustion on the inclined treadmill at increasing speed. The mean of the two warmup periods is reported as one warmup phase angle as the warmup is intended to provide a reference to a participant’s uninstructed breathing pattern. Consistency of the phase angle during the runs to exhaustion was confirmed with no statistically significant difference between the phase angle during the first half of the run (mean 19.7° ±8.3°) and the second half of the run (mean 19.0° ±8.6°) (p = 0.676).
Table 2

Phase angle and time to exhaustion data for all participants.

ParticipantAvg. Phase Angle from Warmup (Deg.)Avg. Phase Angle with Visual Feedback (Deg.)Avg. Phase Angle No Visual Feedback (Deg.)Phase Angle Difference (Visual Feedback–No Visual Feedback)Visual Feedback Time to Ex. (s)No Visual Feedback Time to Ex. (s)Time to Exhaustion Difference (Visual Feedback–No Visual Feedback)
1124.815.731.6-15.9430.4418.412.0
1322.87.817.8-10.01025.9960.865.1
1213.48.317.6-9.2378.3362.515.8
914.520.129.1-9.01309.61337.5-27.9
1014.711.612.3-0.6542.9540.91.9
138.613.814.0-0.2488.9516.2-27.3
519.020.320.20.1323.8300.922.9
712.711.911.10.9369.6397.8-28.2
220.126.725.31.4766.4805.6-39.2
623.631.929.72.1362.0356.06.0
436.831.425.46.0373.8484.7-110.9
311.821.114.36.9563.1521.042.1
829.422.812.410.4729.9661.868.1
Mean 21.718.720.1-1.3589.6589.60.0
SD 8.98.17.37.6297.2292.748.1

Sorted from greatest phase angle improvement to least. Shaded rows indicate a phase angle improvement of 9.0° or greater.

Sorted from greatest phase angle improvement to least. Shaded rows indicate a phase angle improvement of 9.0° or greater. Fig 6 provides a visualization of each participant’s performance with respect to phase angle and time to exhaustion. Each point was calculated by subtracting a participant’s mean value from the treadmill fatigue protocol with no visual feedback from the treadmill fatigue protocol with visual feedback.
Fig 6

Differences in time to exhaustion vs. differences in phase angle.

Each point was calculated by taking the values of phase angle and time to exhaustion from the visual feedback testing day and subtracting these same corresponding variable values from the testing day with no visual feedback for each participant. The colors of the points signify the quadrant that the point lies in, with red representing quadrant I, green for quadrant II, yellow for quadrant III, and orange for quadrant IV.

Differences in time to exhaustion vs. differences in phase angle.

Each point was calculated by taking the values of phase angle and time to exhaustion from the visual feedback testing day and subtracting these same corresponding variable values from the testing day with no visual feedback for each participant. The colors of the points signify the quadrant that the point lies in, with red representing quadrant I, green for quadrant II, yellow for quadrant III, and orange for quadrant IV. Time to exhaustion was not significantly predicted by phase angle (p = 0.853), nor having visual feedback provided (p = 1). Phase angle was not significantly predicted by having visual feedback provided (p = 0.667). The phase angle from the five-minute warmup significantly predicted phase angle during the runs to exhaustion (p = 0.045), meaning that those with a better mean phase angle during the five-minute warmup showed a better mean phase angle during the runs to exhaustion.

Findings for other variables

Initial and final heart rates were not significantly different across testing visits (p = 0.552 and p = 0.802 respectively). Time to exhaustion was not significantly predicted by the order of testing visits (p = .919).

Discussion

Phase angle and time to exhaustion for the participant population

Phase angles were not significantly different across the entire group when comparing the five-minute warmup, visual feedback, and no visual feedback phase angle values. Moreover, the phase angle did not change significantly from start to end of the run to exhaustion. Our mean phase angle from the runs to exhaustion in this study of 19.4° (±7.7°) was similar to the mean phase angle of ten healthy adults undergoing an incremental treadmill protocol to exhaustion in another study (20.0°) [20]. No learning effect was observed with the treadmill fatigue protocol when going from the first testing day to the second, as time to exhaustion was not significantly different between the two (p = 0.919). The observed time to exhaustion in our participants differed from the most similar study in the literature [36], but this difference is most likely due to the fact that Fraga et al. tested well-trained males while our participants were a mix of recreational athletes who run less than 32 kilometers per week. Other studies of time to exhaustion often used cycling instead of running, but we chose running due to its popularity at both a casual and competitive level. The study’s hypothesis that an improvement in breathing could lead to an increased time to exhaustion would be of interest to runners at any level, we chose to test recreational runners under the assumption that they were less likely to have previously learned any type of breathing technique for running than more experienced runners.

Phase angle improvement and time to exhaustion

An improvement in phase angle did not significantly correlate with an increased time to exhaustion in this participant population. However, six participants had an improved phase angle during the run to exhaustion with visual feedback when compared to the run to exhaustion without visual feedback. Of these six participants, four increased time to exhaustion with visual feedback when compared to no visual feedback. Furthermore, there were four participants that had phase angle improvements of 9.0° or more, shown by the shaded rows in Table 2, three of whom had a positive time to exhaustion difference. Analysis of these sub-groups suggests that improving phase angle could lead to an increase in time to exhaustion. However, not all participants improved phase angle when visual feedback was provided. This result could be due to several factors, but a primary one was likely the short familiarization period with the breathing technique of having the chest and abdomen expand and contract in synchrony. This breathing technique has been taught explicitly in previous research [28] and has been shown to have positive impacts on subjects when applied in various settings [9, 10] as it ultimately allows for the maximum amount of oxygen to enter the bloodstream with each breath [9-12]. Had greater steps been taken to familiarize participants with the breathing technique, either through teaching or allowing participants to become familiarized with the visual feedback animations prior to running, there is potential that an improvement in phase angle and thus an increase in time to exhaustion could have been more prominent across all participants. Furthermore, the mean phase angle from the runs to exhaustion being significantly predicted by the mean phase angle from the warmup shows the difficulty of changing breathing pattern with minimal time to practice or learn a new breathing method. It was hypothesized that the animations and instructions would be enough to cause significant change to the breathing pattern of a participant, but this level of familiarization was not enough to induce greater synchrony across all participants, further illustrating the need for practice with any type of new breathing technique.

Future work and limitations

An improvement in phase angle did not ultimately lead to an increase in time to exhaustion across the entire study population. Looking specifically at participants who improved phase angle when visual feedback was provided, there is a possibility that time to exhaustion can be increased with an improved phase angle. An effective and efficient pulmonary system is important for endurance exercise performance, as several respiratory system-related mechanisms can impair oxygen delivery to locomotor muscles, such as arterial desaturation, and compromised cardiac output due to the demands of respiratory work [42]. Whether these factors played a role in our short-duration maximal exercise protocol and/or are related to phase angle remains to be tested. In the future, a more prolonged endurance effort with additional measures of breathing efficiency, such as VE/CO2 could address additional potential impacts of the intervention. Not all participants improved phase angle with visual feedback. As such, one obstacle is ensuring that all participants are breathing in the instructed manner of having the chest and abdomen expand and contract in synchrony. While subjective feedback from participants on the biofeedback system was not collected in a structured way in this study, participants were told to let the research team know if any breathing instructions were unclear or if they experienced any shortness of breath while running, and ultimately no participants reported any confusion on instructions or dyspnea during running. Thoraco-abdominal synchrony can be improved by manual breathing re-education methods or having a familiarization session for the participant with visual feedback. Given that this specific technique of visual feedback on breathing has not been used before, additional studies to gauge the time required for participants to fully learn this biofeedback technique are needed. With an established re-education method or familiarization session in place for future work, further time-series analyses can be done to observe phase angle patterns over time. As shown in Table 2, the average time to exhaustion in this population of recreational runners was under 10 minutes, with six participants reaching volitional exhaustion in less than seven minutes. Studies with similar research objectives across multiple testing days [31, 33] utilized protocols that had participants exercise at a constant pace for an extended period which led to significant differences between the testing days. This further illustrates the potential limitation that a lower-intensity constant-pace run could lead to a larger difference observed between the two testing days. A constant-pace protocol tailored to each participant could further isolate the variable of breathing during maximal exertion exercise as participants would not need to meet the neuromuscular demands associated with increasing cadence throughout the protocol. As stated previously, given that the population in this study ran a wide-ranging number of kilometers per week, our protocol was selected to ensure that each individual could reach a true exhaustion point rather than not being able to keep pace with the treadmill. Ensuring that participants reached a true exhaustion point in each testing session allowed us to confidently analyze the role that breathing played during maximal exertion exercise, and the role that breathing plays could potentially be greater in a constant-pace protocol. As with many physiological questions, the findings of this study are somewhat specific to the exercise protocol performed. A primary limitation of this study was not having a testing day with a run to exhaustion without visual feedback or breathing instructions. This was not done for the primary reason of time commitment for participants, as well as the study ultimately being designed to isolate the impact that visual feedback had on participants. Our observation of time to exhaustion not being significantly predicted by the order of testing visits also suggests that the verbal or visual cues given on the first testing visit did not affect the results on the second testing visit. Additional limitations included the specific population tested and the fatigue protocol that participants were put through. It is possible that other running populations (such as novice runners of less than eight kilometers per week or more experienced runners of more than thirty-two kilometers per week) may have baseline phase angles that are inefficient and could see benefits from having visual feedback provided. Indirect calorimetry and spirometry testing on a separate day could be used in future studies to directly relate phase angle to other breathing and metabolic variables to determine the impact of visual feedback on running economy. It is also unknown to what extent the harness worn by participants impacted their breathing pattern, but it was assumed to have minimal influence. An additional limitation is the use of visual feedback for breathing instruction, which cannot be directly translated to overground running. However, given the lack of existing knowledge on whether breathing patterns during running can be changed at all, we believe that an approach providing clear, unambiguous feedback is a valuable first step to motivate the development of and assess the efficacy of other more portable types of feedback such as audio or haptic feedback [27]. Moreover, while many runners prefer field running, treadmill running is also very common, especially during wet or cold seasons. Therefore, we believe that further investigation of visual feedback to determine the upper limits of breathing training would be useful in parallel to developing non-visual breathing feedback approaches for overground running. Lastly, even with filtering applied to the raw voltages from the RIP bands based on the recommendations from previous studies [23] and a minimum tidal volume of 48mL used to minimize the number of erroneous breaths identified, over-identification of breaths could lead to noise in the estimation of the average phase angle. The dynamic nature of running with large vertical accelerations of the torso could have exacerbated this problem relative to studies of breathing during walking, sitting, or lying down.

Conclusions

Visual feedback did not consistently lead to increased breathing efficiency or time to exhaustion across a population of healthy recreational runners. However, sub-analysis of participants with a phase angle improvement reveals the possibility that time to exhaustion can be increased if breathing improvements are made. Familiarization with any form of visual feedback or breathing technique should be of utmost importance in future studies. 29 Nov 2021
PONE-D-21-36124
The influence of receiving real-time visual feedback on breathing during treadmill running to exhaustion
PLOS ONE Dear Dr. Passafiume, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.
Please provide addition details in the methods (outlined below) relating to the signal processing for the RIP sensors. Please submit your revised manuscript by Jan 13 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Caroline Sunderland Academic Editor PLOS ONE Journal Requirements: 1. When submitting your revision, we need you to address these additional requirements. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and " ext-link-type="uri" xlink:type="simple">https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf" 2. We note that you have stated that you will provide repository information for your data at acceptance. Should your manuscript be accepted for publication, we will hold it until you provide the relevant accession numbers or DOIs necessary to access your data. If you wish to make changes to your Data Availability statement, please describe these changes in your cover letter and we will update your Data Availability statement to reflect the information you provide. 3. Please include your full ethics statement in the ‘Methods’ section of your manuscript file. In your statement, please include the full name of the IRB or ethics committee who approved or waived your study, as well as whether or not you obtained informed written or verbal consent. If consent was waived for your study, please include this information in your statement as well. Additional Editor Comments: There are some concerns regarding the detail provided in the methods for using the RIP sensors. Therefore in the methods can you please provide: 1) Details regarding raw signal processing and breath onset detection 2) A raw data trace of the signal. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step. 31 Dec 2021 All responses are provided in the "Response to Reviewers" file. Submitted filename: Response to Reviewers.docx Click here for additional data file. 17 Jan 2022
PONE-D-21-36124R1
The influence of receiving real-time visual feedback on breathing during treadmill running to exhaustion
PLOS ONE Dear Dr. Passafiume, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please submit your revised manuscript by Mar 03 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-emailutm_source=authorlettersutm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Caroline Sunderland Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: (No Response) Reviewer #2: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes Reviewer #2: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes Reviewer #2: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: Yes Reviewer #2: No ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes Reviewer #2: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: I would like to commend the authors for this novel, important study seeking to improve breathing pattern during running. The exploration of such techniques in exercise is understudied. Furthermore, RIP sensors enable new possibilities when properly used. I stipulated that I would review this manuscript once some key methodological concerns were cleared up regarding the use of RIP to quantify the variable of interest in this study. Based on your edits, I am happy to review the rest of this manuscript. • Line 31 “breathing synchronicity” – better to use one of the accepted terms “thoraco-abdominal coordination” or “thoraco-lumbar synchrony” • Lines 41-42 is this reference correct? • Lines 44-46 not sure this connects the previous and next sentences… can you provide info re: how breathing provides o2 and clears co2? • Lines 49-50 this is a brief, bold statement supported by much theoretical knowledge but scarce experimental evidence. Citations 9-11 do not refer to T-L synchrony during exercise. Can you expand the concept of T-L synchrony independently before introducing RIP? I suggest you refer to the following: Bernardi, E., Pratali, L., Mandolesi, G., Spiridonova, M., Roi, G. S., Cogo, A. (2017). Thoraco-abdominal coordination and performance during uphill running at altitude. PLoS One, 12(3), e0174927. • Lines 53-57 I suggest you check some updated references on RIP validity as there appear to be advances in this space in the last 10y. Specifically there are many recent studies on another commercial RIP device (Hexoskin): Harbour, E., Lasshofer, M., Genitrini, M., Schwameder, H. (2021). Enhanced Breathing Pattern Detection during Running Using Wearable Sensors. Sensors (Basel), 21(16). • Lines 54-57 there are several studies examining the effect of breathing pattern interventions upon running. For a start, check out: Bahensky, P., Bunc, V., Malatova, R., Marko, D., Grosicki, G. J., Schuster, J. (2021). Impact of a Breathing Intervention on Engagement of Abdominal, Thoracic, and Subclavian Musculature during Exercise, a Randomized Trial. J Clin Med, 10(16) and Matsumoto, T., Masuda, T., Hotta, K., Shimizu, R., Ishii, A., Kutsuna, T., Yamamoto, K., Hara, M., Takahira, N., Matsunaga, A. (2011). Effects of prolonged expiration breathing on cardiopulmonary responses during incremental exercise. Respir. Physiol. Neurobiol., 178(2), 275-282. • Lines 61-62 please populate this with normal values during exercise (Ref 16?). • Lines 72-76 can you separate and clarify these points? Specifically, “breathing in healthy individuals is typically not optimally efficient” is a large claim likely difficult to substantiate with research. Maybe you mean to specify that healthy exercisers present with suboptimal T-L synchrony values and that improvement might also affect performance? • Lines 80-86 can be easily be combined and made more concise. • Lines 176-187 these lines all describe breath/flow reversal detection; can you explicitly label as such? Furthermore, if you have TV data, why not present this in results? Just a suggestion if there might be interesting comparisons. • Lines 190-192 averages are good; do you have any other time-series analysis metrics that might show different aspects of breathing pattern? Propose variability of phase angle (as SD or CV) or slope (change from beginning to end). If you do not have these, include this caveat in your discussion. • Lines 252-255 is this really the most similar study for comparison? Suggest to compare instead with another breathing strategy study using time to exhaustion: Wojta, D., Flores, X., Andres, F. (1987). 509: Effect of “Breathplay” on the Physiological Performance of Trained Cyclists. Med. Sci. Sports Exerc., 19(2), S85 or Dallam, G., McClaran, S., Cox, D., Foust, C. (2018). Effect of Nasal Versus Oral Breathing on Vo2max and Physiological Economy in Recreational Runners Following an Extended Period Spent Using Nasally Restricted Breathing. International Journal of Kinesiology and Sports Science, 6(2) or Vickery, R. L. (2008). The effect of breathing pattern retraining on performance in competitive cyclists [Auckland University of Technology]. • Lines 255-256 have you considered the unique constraints on breathing that running confers versus cycling and other sports? Suggest to check Elliott, A. D., Grace, F. (2010). An examination of exercise mode on ventilatory patterns during incremental exercise. Eur. J. Appl. Physiol., 110(3), 557-562. • Lines 258-259 do you have any justification for this statement that experienced runners have a more efficient breathing pattern? Check out Salazar-Martinez, E., de Matos, T. R., Arrans, P., Santalla, A., Orellana, J. N. (2018). Ventilatory efficiency response is unaffected by fitness level, ergometer type, age or body mass index in male athletes. Biol. Sport, 35(4), 393-398. Moreover, elite athletes and females might be even more predisposed to respiratory limitations, especially at maximal intensity, as recently reviewed: Dempsey, J.A., La Gerche, A., and Hull, J.H. (2020). Is the healthy respiratory system built just right, overbuilt, or underbuilt to meet the demands imposed by exercise? J Appl Physiol (1985) 129, 1235-1256. • Lines 260-266 does not strengthen this discussion for me. If you wish to retain, please expand upon why this protocol selection is important: is it better simply for intra-subject equivalence? Is it superior for eliciting respiratory limitations? • Lines 279-281 can you put this in context with the results of Bernardi, 2017 as mentioned above? What does T-L synchrony have to do with insp/exp airflow and the work of breathing? • Lines 281-284 do you have any idea what amount of time is needed to optimize this familiarization? There should be some contextual comparison in biofeedback studies and some of the previous references in learning breathing techniques. • Lines 285-288 clunky; reword • Can you add some comments to the discussion re: field vs. laboratory running? The implication here is that this breath retraining might have long-term effects on breathing during running. Can you also make a comment on feedback learning/self-awareness of T-L synchrony if expected to carry into field running? • Lines 297-302 a large limitation I see is missing subjective feedback such as dyspnea, perceived efficacy/difficulty (to breathing instructions), and cognitive load. Please comment. • Line 300-301 first part of sentence says nothing; how about “manual breathing re-education methods” or the like? • Lines 303-306 also consider the limitations of condition randomization – the order of verbal vs visual cues might have affected the instruction adherence of the next session. • Can you sharpen figure 5? Not only it is blurry, but also unclear. Specifically, I am guessing that there should not be an arrow between the summed tidal volume and phase angle graphs. Reviewer #2: Dear Authors, Thank you for addressing all the comments. Your revisions substantially improved the content of the manuscript. Keep up the good work. Best regards, Reviewer ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No Reviewer #2: Yes: Seyed Hamed Mousavi [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.
31 Jan 2022 All responses are provided in the "Response to Reviewers" file. Submitted filename: Response to Reviewers.docx Click here for additional data file. 17 Mar 2022
PONE-D-21-36124R2
The influence of receiving real-time visual feedback on breathing during treadmill running to exhaustion
PLOS ONE Dear Dr. Passafiume, Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process. Please respond to the reviewers remaining comments, addressing them in a point by point manner.
Please submit your revised manuscript by May 01 2022 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file. Please include the following items when submitting your revised manuscript:
If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter. A rebuttal letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'. A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'. An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'. If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-emailutm_source=authorlettersutm_campaign=protocols. We look forward to receiving your revised manuscript. Kind regards, Caroline Sunderland Academic Editor PLOS ONE Journal Requirements: Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice. [Note: HTML markup is below. Please do not edit.] Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: (No Response) ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: I Don't Know ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: (No Response) ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No [NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.] While revising your submission, please upload your figure files to the Preflight Analysis and Conversion Engine (PACE) digital diagnostic tool, https://pacev2.apexcovantage.com/. PACE helps ensure that figures meet PLOS requirements. To use PACE, you must first register as a user. Registration is free. Then, login and navigate to the UPLOAD tab, where you will find detailed instructions on how to use the tool. If you encounter any issues or have any questions when using PACE, please email PLOS at figures@plos.org. Please note that Supporting Information files do not need this step.
Submitted filename: Reviewer comments 2.docx Click here for additional data file. 11 May 2022 All responses are provided in the "Response to Reviewers" file. Submitted filename: Response to Reviewers.docx Click here for additional data file. 9 Jun 2022 The influence of receiving real-time visual feedback on breathing during treadmill running to exhaustion PONE-D-21-36124R3 Dear Dr. Passafiume, We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements. Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication. An invoice for payment will follow shortly after the formal acceptance. To ensure an efficient process, please log into Editorial Manager at http://www.editorialmanager.com/pone/, click the 'Update My Information' link at the top of the page, and double check that your user information is up-to-date. If you have any billing related questions, please contact our Author Billing department directly at authorbilling@plos.org. If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org. Kind regards, Caroline Sunderland Academic Editor PLOS ONE Additional Editor Comments (optional): Reviewers' comments: Reviewer's Responses to Questions Comments to the Author 1. If the authors have adequately addressed your comments raised in a previous round of review and you feel that this manuscript is now acceptable for publication, you may indicate that here to bypass the “Comments to the Author” section, enter your conflict of interest statement in the “Confidential to Editor” section, and submit your "Accept" recommendation. Reviewer #1: All comments have been addressed ********** 2. Is the manuscript technically sound, and do the data support the conclusions? The manuscript must describe a technically sound piece of scientific research with data that supports the conclusions. Experiments must have been conducted rigorously, with appropriate controls, replication, and sample sizes. The conclusions must be drawn appropriately based on the data presented. Reviewer #1: Yes ********** 3. Has the statistical analysis been performed appropriately and rigorously? Reviewer #1: Yes ********** 4. Have the authors made all data underlying the findings in their manuscript fully available? The PLOS Data policy requires authors to make all data underlying the findings described in their manuscript fully available without restriction, with rare exception (please refer to the Data Availability Statement in the manuscript PDF file). The data should be provided as part of the manuscript or its supporting information, or deposited to a public repository. For example, in addition to summary statistics, the data points behind means, medians and variance measures should be available. If there are restrictions on publicly sharing data—e.g. participant privacy or use of data from a third party—those must be specified. Reviewer #1: No ********** 5. Is the manuscript presented in an intelligible fashion and written in standard English? PLOS ONE does not copyedit accepted manuscripts, so the language in submitted articles must be clear, correct, and unambiguous. Any typographical or grammatical errors should be corrected at revision, so please note any specific errors here. Reviewer #1: Yes ********** 6. Review Comments to the Author Please use the space provided to explain your answers to the questions above. You may also include additional comments for the author, including concerns about dual publication, research ethics, or publication ethics. (Please upload your review as an attachment if it exceeds 20,000 characters) Reviewer #1: (No Response) ********** 7. PLOS authors have the option to publish the peer review history of their article (what does this mean?). If published, this will include your full peer review and any attached files. If you choose “no”, your identity will remain anonymous but your review may still be made public. Do you want your identity to be public for this peer review? For information about this choice, including consent withdrawal, please see our Privacy Policy. Reviewer #1: No ********** 27 Jun 2022 PONE-D-21-36124R3 The influence of receiving real-time visual feedback on breathing during treadmill running to exhaustion Dear Dr. Passafiume: I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS ONE. Congratulations! Your manuscript is now with our production department. If your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information please contact onepress@plos.org. If we can help with anything else, please email us at plosone@plos.org. Thank you for submitting your work to PLOS ONE and supporting open access. Kind regards, PLOS ONE Editorial Office Staff on behalf of Dr. Caroline Sunderland Academic Editor PLOS ONE
  36 in total

1.  Quantifying asynchronous breathing.

Authors:  Michael L Johnson; Paul Suratt
Journal:  Methods Enzymol       Date:  2004       Impact factor: 1.600

2.  Prevalence and incidence of lower extremity injuries in male marathon runners.

Authors:  M Van Middelkoop; J Kolkman; J Van Ochten; S M A Bierma-Zeinstra; B Koes
Journal:  Scand J Med Sci Sports       Date:  2007-06-06       Impact factor: 4.221

3.  Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt during exercise tests.

Authors:  Lisa Kent; Brenda O'Neill; Gareth Davison; Alan Nevill; J Stuart Elborn; Judy M Bradley
Journal:  Respir Physiol Neurobiol       Date:  2009-04-08       Impact factor: 1.931

4.  Acute effects of deep diaphragmatic breathing in COPD patients with chronic respiratory insufficiency.

Authors:  M Vitacca; E Clini; L Bianchi; N Ambrosino
Journal:  Eur Respir J       Date:  1998-02       Impact factor: 16.671

5.  Aerobic capacity and fractional utilisation of aerobic capacity in elite and non-elite male and female marathon runners.

Authors:  R J Maughan; J B Leiper
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1983

6.  Respiratory inductance plethysmography: calibration techniques, their validation and the effects of posture.

Authors:  J R Stradling; G A Chadwick; C Quirk; T Phillips
Journal:  Bull Eur Physiopathol Respir       Date:  1985 Jul-Aug

7.  Carbohydrate mouth rinse enhances time to exhaustion during treadmill exercise.

Authors:  Cindy Fraga; Bruna Velasques; Alexander J Koch; Marco Machado; Dailson Paulucio; Pedro Ribeiro; Fernando Augusto Monteiro Saboia Pompeu
Journal:  Clin Physiol Funct Imaging       Date:  2015-08-24       Impact factor: 2.273

8.  Thoraco-abdominal coordination and performance during uphill running at altitude.

Authors:  Eva Bernardi; Lorenza Pratali; Gaia Mandolesi; Maria Spiridonova; Giulio Sergio Roi; Annalisa Cogo
Journal:  PLoS One       Date:  2017-03-31       Impact factor: 3.240

9.  Prosthetic shape, but not stiffness or height, affects the maximum speed of sprinters with bilateral transtibial amputations.

Authors:  Paolo Taboga; Owen N Beck; Alena M Grabowski
Journal:  PLoS One       Date:  2020-02-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.