Literature DB >> 35794486

Pilot investigation on biostability of drinking water distribution systems under water source switching.

Kejia Zhang1, Xiaogang Wu1, Tuqiao Zhang1, Cheng Cen1, Ruyin Mao1, Renjie Pan2,3,4.   

Abstract

Water quality deterioration of drinking water distribution systems (DWDSs) caused by water source switching has been reported previously. However, systematic investigation of the biostability of DWDS under water source switching is limited. Aged pipes, including three commonly used pipe materials dug out from a practical DWDS, were used to systematically investigate the biofilm stability mechanism of DWDS under water source switching to quality-improved water. An increase in adenosine triphosphate (ATP) concentration in the bulk water during the initial stage of the switching period was observed, indicating the risk of biofilm release through aged pipe surfaces after water source switching. Sloughing of biofilms might contribute to temporary instability. From day 35, the ATP concentration in the polyethylene (PE) and plastic stainless steel composite (PS) pipes were maintained at approximately 2.40 and 2.56 ng/L, respectively. In contrast, the ATP concentration in the ductile iron (DI) pipes was higher, at approximately 3.43 ng/L from day 42. The water quality variation could cause areas of the biofilm to slough and reduce the biomass of biofilm, causing partial alteration of the microbial community. 16S rRNA gene amplicon sequencing-based functional prediction revealed that the biofilm could increase the abundance of chlorine-resistant bacteria attributed to the increase in Pseudomonas and Methylobacterium after switching to quality-improved water. Moreover, the profiles of specific pathways linked to human diseases, antibiotic resistance, and antibiotic biosynthesis revealed that the safety of the biofilm could improve after switching to quality-improved water. KEY POINTS: • The PE and PS biofilm showed improved resistance to water quality perturbation. • Greater number of Methylobacterium was found in the biofilm after water source switching. • 3.16S gene-based metagenomics prediction revealed that the safety of the biofilm under water source switching.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Adenosine triphosphate; Biostability; Drinking water distribution system; Quality-improved water; Switching

Mesh:

Substances:

Year:  2022        PMID: 35794486     DOI: 10.1007/s00253-022-12050-6

Source DB:  PubMed          Journal:  Appl Microbiol Biotechnol        ISSN: 0175-7598            Impact factor:   5.560


  33 in total

1.  Spatial and temporal analogies in microbial communities in natural drinking water biofilms.

Authors:  I Douterelo; M Jackson; C Solomon; J Boxall
Journal:  Sci Total Environ       Date:  2016-12-30       Impact factor: 7.963

2.  Effects of phosphate addition on biofilm bacterial communities and water quality in annular reactors equipped with stainless steel and ductile cast iron pipes.

Authors:  Hyun-Jung Jang; Young-June Choi; Hee-Myong Ro; Jong-Ok Ka
Journal:  J Microbiol       Date:  2012-02-27       Impact factor: 3.422

3.  Impacts of water quality on the corrosion of cast iron pipes for water distribution and proposed source water switch strategy.

Authors:  Jun Hu; Huiyu Dong; Qiang Xu; Wencui Ling; Jiuhui Qu; Zhimin Qiang
Journal:  Water Res       Date:  2017-10-31       Impact factor: 11.236

Review 4.  An overview on the reactors to study drinking water biofilms.

Authors:  I B Gomes; M Simões; L C Simões
Journal:  Water Res       Date:  2014-06-03       Impact factor: 11.236

5.  Bacterial Community Shift Drives Antibiotic Resistance Promotion during Drinking Water Chlorination.

Authors:  Shuyu Jia; Peng Shi; Qing Hu; Bing Li; Tong Zhang; Xu-Xiang Zhang
Journal:  Environ Sci Technol       Date:  2015-10-02       Impact factor: 9.028

6.  Elevated Blood Lead Levels in Children Associated With the Flint Drinking Water Crisis: A Spatial Analysis of Risk and Public Health Response.

Authors:  Mona Hanna-Attisha; Jenny LaChance; Richard Casey Sadler; Allison Champney Schnepp
Journal:  Am J Public Health       Date:  2015-12-21       Impact factor: 9.308

7.  Measurement and interpretation of microbial adenosine tri-phosphate (ATP) in aquatic environments.

Authors:  Frederik Hammes; Felix Goldschmidt; Marius Vital; Yingying Wang; Thomas Egli
Journal:  Water Res       Date:  2010-06-02       Impact factor: 11.236

8.  Impact of orthophosphate addition on biofilm development in drinking water distribution systems.

Authors:  Mbarka Gouider; Jalel Bouzid; Sami Sayadi; Antoine Montiel
Journal:  J Hazard Mater       Date:  2009-02-07       Impact factor: 10.588

9.  Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems.

Authors:  I Douterelo; S Husband; V Loza; J Boxall
Journal:  Appl Environ Microbiol       Date:  2016-06-30       Impact factor: 4.792

10.  Comparison of Whole-Genome Sequences of Legionella pneumophila in Tap Water and in Clinical Strains, Flint, Michigan, USA, 2016.

Authors:  Emily Garner; Connor L Brown; David Otto Schwake; William J Rhoads; Gustavo Arango-Argoty; Liqing Zhang; Guillaume Jospin; David A Coil; Jonathan A Eisen; Marc A Edwards; Amy Pruden
Journal:  Emerg Infect Dis       Date:  2019-11       Impact factor: 6.883