Literature DB >> 3579383

Functional assessment of the hand: reproducibility, acceptability, and utility of a new system for measuring strength.

P Helliwell, A Howe, V Wright.   

Abstract

A new system for measuring strength of the hand using a torsion dynamometer linked to a microprocessor is described. The system permits analysis of timed squeezes of both grip and pinch and is adjustable to all sizes of hand and degrees of hand deformity. Results obtained with the system were found to be reproducible, and the rigid device was acceptable to a group of patients with arthritic hands. In rheumatoid arthritis there is a marked reduction in maximum grip and pinch strength, together with a prolongation of the time taken to reach this maximum, and increased fatigue. The limitations of grip strength as a measure of function of the hand are discussed.

Entities:  

Mesh:

Year:  1987        PMID: 3579383      PMCID: PMC1002100          DOI: 10.1136/ard.46.3.203

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  13 in total

1.  Quantitative and qualitative analysis of joint stiffness in normal subjects and in patients with connective tissue diseases.

Authors:  V WRIGHT; R J JOHNS
Journal:  Ann Rheum Dis       Date:  1961-03       Impact factor: 19.103

2.  Electromyographic Changes in Rheumatoid Arthritis.

Authors:  V L Steinberg; C B Parry
Journal:  Br Med J       Date:  1961-03-04

3.  An assessment of grip strength measurement in rheumatoid arthritis.

Authors:  P Lee; A Baxter; W C Dick; J Webb
Journal:  Scand J Rheumatol       Date:  1974       Impact factor: 3.641

4.  Functional assessment of the rheumatoid hand.

Authors:  D K Clawson; W A Souter; C J Carthum; M L Hymen
Journal:  Clin Orthop Relat Res       Date:  1971       Impact factor: 4.176

5.  Measurement of the quality of hand contractions.

Authors:  B W Duym; G Pfurtscheller
Journal:  Med Biol Eng Comput       Date:  1984-05       Impact factor: 2.602

6.  A microcomputer controlled hand assessment system used for clinical measurement.

Authors:  A R Jones; A Unsworth; I Haslock
Journal:  Eng Med       Date:  1985-10

7.  An objective measurement of change in morning stiffness.

Authors:  D B Myers; K Wilson; D G Palmer
Journal:  Rheumatol Int       Date:  1981       Impact factor: 2.631

8.  Electromyographic measurement of fatigue in rheumatoid arthritis and neuromuscular disease.

Authors:  J A Lenman; J L Potter
Journal:  Ann Rheum Dis       Date:  1966-01       Impact factor: 19.103

9.  Hand grip function in patients with rheumatoid arthritis.

Authors:  D B Myers; D M Grennan; D G Palmer
Journal:  Arch Phys Med Rehabil       Date:  1980-08       Impact factor: 3.966

10.  An apparatus to assess function of the hand.

Authors:  P S Walker; W Davidson; M J Erkman
Journal:  J Hand Surg Am       Date:  1978-03       Impact factor: 2.230

View more
  8 in total

1.  A component analysis of the generation and release of isometric force in Parkinson's disease.

Authors:  N Jordan; H J Sagar; J A Cooper
Journal:  J Neurol Neurosurg Psychiatry       Date:  1992-07       Impact factor: 10.154

2.  Static dynamometer for the measurement of multidirectional forces exerted by the thumb.

Authors:  D Bourbonnais; P Duval
Journal:  Med Biol Eng Comput       Date:  1991-07       Impact factor: 2.602

Review 3.  Measuring hand grip strength in rheumatoid arthritis.

Authors:  Susie C Higgins; Jo Adams; Rodney Hughes
Journal:  Rheumatol Int       Date:  2018-04-06       Impact factor: 2.631

4.  An evaluation of the dynamic qualities of isometric grip strength.

Authors:  P S Helliwell; A Howe; V Wright
Journal:  Ann Rheum Dis       Date:  1988-11       Impact factor: 19.103

5.  Relationship between weakness and muscle wasting in rheumatoid arthritis.

Authors:  P S Helliwell; S Jackson
Journal:  Ann Rheum Dis       Date:  1994-11       Impact factor: 19.103

6.  Impact of botulinum toxin type A on disability and carer burden due to arm spasticity after stroke: a randomised double blind placebo controlled trial.

Authors:  B B Bhakta; J A Cozens; M A Chamberlain; J M Bamford
Journal:  J Neurol Neurosurg Psychiatry       Date:  2000-08       Impact factor: 10.154

7.  Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices.

Authors:  Ippei Watanabe; Mayumi Nagata; Hiroyuki Matsushima
Journal:  Clin Ophthalmol       Date:  2019-09-23

8.  Strengthening and stretching for rheumatoid arthritis of the hand (SARAH): design of a randomised controlled trial of a hand and upper limb exercise intervention--ISRCTN89936343.

Authors:  Jo Adams; Chris Bridle; Sukhdeep Dosanjh; Peter Heine; Sarah E Lamb; Joanne Lord; Christopher McConkey; Vivien Nichols; Francine Toye; Martin R Underwood; Mark A Williams; Esther M Williamson
Journal:  BMC Musculoskelet Disord       Date:  2012-11-24       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.