Literature DB >> 35788893

Overcoming the impact of physiologic tremors in ophthalmology.

Gurfarmaan Singh1,2, Wilson Wong Jun Jie3, Michelle Tian Sun4,3, Robert Casson4,3, Dinesh Selva4,3, WengOnn Chan4,3.   

Abstract

PURPOSE: Ophthalmic surgery involves the manipulation of micron-level sized structures such as the internal limiting membrane where tactile sensation is practically absent. All humans have physiologic tremors that are of low amplitude and not discernible to the naked eye; they do not adversely affect the majority of the population's daily functioning. However, during microsurgery, such tremors can be problematic. In this review, we focus on the impact of physiological tremors on ophthalmic microsurgery and offer a comparative discussion on the impact of such tremors on other surgical specialties.
METHODS: A single investigator used the MEDLINE database (via PubMed) to search for and identify articles for inclusion in this systematic review. Ten key factors were identified as potentially having an impact on tremor amplitude: beta-blockers, muscle fatigue, robotic systems, handheld tools/micromanipulators, armrests/wrist supports, caffeine, diet, sleep deprivation, consuming alcohol, and workouts (exercise). These key terms were then searched using the advanced Boolean search tool and operators (i.e., AND, OR) available on PubMed: (*keyword*) AND (surgeon tremor OR microsurgery tremor OR hand steadiness OR simulator score).
RESULTS: Ten studies attempted to quantify the baseline severity of operator physiologic tremor. Approximately 89% of studies accessing the impact of tremors on performance in regards to surgical metrics reported an improvement in performance compared to 57% of studies concluding that tremor elimination was of benefit when considering procedural outcomes.
CONCLUSIONS: Robotic technology, new instruments, exoskeletons, technique modifications, and lifestyle factors have all demonstrated the potential to assist in overcoming tremors in ophthalmology.
© 2022. The Author(s).

Entities:  

Keywords:  Exoskeletons; Instruments; Lifestyle factors; Ophthalmology; Physiologic tremors; Robotics; Technique modifications

Year:  2022        PMID: 35788893     DOI: 10.1007/s00417-022-05718-2

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  79 in total

1.  The resonant component of human physiological hand tremor is altered by slow voluntary movements.

Authors:  Martin Lakie; Carlijn A Vernooij; Timothy M Osborne; Raymond F Reynolds
Journal:  J Physiol       Date:  2012-03-19       Impact factor: 5.182

2.  A parallel robot to assist vitreoretinal surgery.

Authors:  Taiga Nakano; Naohiko Sugita; Takashi Ueta; Yasuhiro Tamaki; Mamoru Mitsuishi
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-06-17       Impact factor: 2.924

3.  The robotic ENT microsurgery system: A novel robotic platform for microvascular surgery.

Authors:  Allen L Feng; Christopher R Razavi; Pranav Lakshminarayanan; Zaid Ashai; Kevin Olds; Marcin Balicki; Zhen Gooi; Andrew T Day; Russell H Taylor; Jeremy D Richmon
Journal:  Laryngoscope       Date:  2017-06-05       Impact factor: 3.325

Review 4.  Differentiation and diagnosis of tremor.

Authors:  Paul Crawford; Ethan E Zimmerman
Journal:  Am Fam Physician       Date:  2011-03-15       Impact factor: 3.292

5.  Determinants of physiologic tremor in a large normal population.

Authors:  J Raethjen; F Pawlas; M Lindemann; R Wenzelburger; G Deuschl
Journal:  Clin Neurophysiol       Date:  2000-10       Impact factor: 3.708

6.  Auditory force feedback substitution improves surgical precision during simulated ophthalmic surgery.

Authors:  Nathan Cutler; Marcin Balicki; Mark Finkelstein; Jiangxia Wang; Peter Gehlbach; John McGready; Iulian Iordachita; Russell Taylor; James T Handa
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-02-15       Impact factor: 4.799

Review 7.  Physiologic and pathologic tremors. Diagnosis, mechanism, and management.

Authors:  J Jankovic; S Fahn
Journal:  Ann Intern Med       Date:  1980-09       Impact factor: 25.391

Review 8.  Tremor.

Authors:  W Jeffrey Elias; Binit B Shah
Journal:  JAMA       Date:  2014-03-05       Impact factor: 56.272

9.  Physiological tremor increases when skeletal muscle is shortened: implications for fusimotor control.

Authors:  Kian Jalaleddini; Akira Nagamori; Christopher M Laine; Mahsa A Golkar; Robert E Kearney; Francisco J Valero-Cuevas
Journal:  J Physiol       Date:  2017-11-19       Impact factor: 5.182

10.  The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.

Authors:  Matthew J Page; Joanne E McKenzie; Patrick M Bossuyt; Isabelle Boutron; Tammy C Hoffmann; Cynthia D Mulrow; Larissa Shamseer; Jennifer M Tetzlaff; Elie A Akl; Sue E Brennan; Roger Chou; Julie Glanville; Jeremy M Grimshaw; Asbjørn Hróbjartsson; Manoj M Lalu; Tianjing Li; Elizabeth W Loder; Evan Mayo-Wilson; Steve McDonald; Luke A McGuinness; Lesley A Stewart; James Thomas; Andrea C Tricco; Vivian A Welch; Penny Whiting; David Moher
Journal:  BMJ       Date:  2021-03-29