Literature DB >> 3578138

A new potentiator of red blood cell antigen-antibody reactions.

S J Nance, G Garratty.   

Abstract

A new technic using polyethylene glycol (PEG) was developed to detect and enhance weak red blood cell/antibody reactions. Twenty percent PEG of 4,000 molecular weight was found to be optimal. Weakly reactive antibodies (n = 25) were tested by PEG, Polybrene, and low ionic strength saline (LISS); 64% were strongest in PEG, 28% reacted equally in PEG as in Polybrene or LISS, 8% reacted weaker in PEG than in Polybrene or LISS. Stronger antibodies (n = 11) were titrated and compared in the three technics; in 10 of 11 titrations, PEG was better or equal to Polybrene and LISS. The false positive rate with the use of PEG and anti-IgG was 1.5% with the use of random sera. Sera from patients (n = 24) with hemolytic transfusion reactions and no detectable antibody by routine technics were tested; two sera had specific antibodies by the PEG technic. This new technic should be a valuable aid in the detection and identification of weak antibodies.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3578138     DOI: 10.1093/ajcp/87.5.633

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

1.  Factors affecting the antigen-antibody reaction.

Authors:  Roberto Reverberi; Lorenzo Reverberi
Journal:  Blood Transfus       Date:  2007-11       Impact factor: 3.443

2.  Increased detection of clinically significant antibodies and decreased incidence of delayed haemolytic transfusion reaction with the indirect antiglobulin test potentiated by polyethylene glycol compared to albumin: a Japanese study.

Authors:  Miho Okutsu; Hitoshi Ohto; Hiroyasu Yasuda; Kinuyo Kawabata; Satoshi Ono; Shunnichi Saito; Akiko Sugawara; Masami Kikuchi; Saori Miura; Youko Ishii; Kazuya Watanabe; Yuriko Tohyama; Kenneth E Nollet
Journal:  Blood Transfus       Date:  2010-11-26       Impact factor: 3.443

3.  Evaluation of a modified IAT-gel with polyethylenglycol (PEG) addition method for red blood cell antibody identification.

Authors:  L Gustafsson; A Wikman; J Lundahl
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

4.  A rare case of antibody against enhancement media interfering with crossmatching: A case report and review of literature.

Authors:  S Anuragaa; Dibyajyoti Sahoo; B Abhishekh; Revathy Nair
Journal:  Asian J Transfus Sci       Date:  2021-06-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.