Literature DB >> 3577737

Bone cement improved by vacuum mixing and chilling.

L Lidgren, B Bodelind, J Möller.   

Abstract

Two mixing methods, hand and vacuum mixing, were compared using high viscosity, high molecular, antibiotic containing polymethylmethacrylate kept at two different temperatures, 4 degrees C and 21 degrees C, prior to mixing. The mechanical properties, i.e., fracture strength, maximum deflection, modulus of elasticity and hardness, were improved by vacuum mixing when compared with hand mixing at both temperatures. The fatigue life was 10 times longer after vacuum mixing. Chilling prior to mixing made the mixing easier and improved the handling characteristics. Vacuum mixing delayed the setting time by 1 minute, but also decreased the peak temperature. Radiographic analysis showed that vacuum mixing mainly reduced the microporosity, but also the macroporosity. The mechanical properties deteriorated slightly after 2 months in Ringer's solution, but the differences between the mixing procedures remained unchanged.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3577737     DOI: 10.3109/17453678709146338

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  7 in total

1.  Fatigue of bone cement with simulated stem interface porosity.

Authors:  S Tepic; U Soltész
Journal:  J Mater Sci Mater Med       Date:  1998-12       Impact factor: 3.896

2.  In vitro evaluation of thermal frontally polymerized thiol-ene composites as bone augments.

Authors:  Nicholas P Totaro; Zachari D Murphy; Abigail E Burcham; Connor T King; Thomas F Scherr; Christopher O Bounds; Vinod Dasa; John A Pojman; Daniel J Hayes
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-06-09       Impact factor: 3.368

3.  Direct evidence of "damage accumulation" in cement mantles surrounding femoral hip stems retrieved at autopsy: cement damage correlates with duration of use and BMI.

Authors:  A Race; M A Miller; T H Izant; K A Mann
Journal:  J Biomech       Date:  2011-07-28       Impact factor: 2.712

4.  Does vacuum-mixing improve the fatigue properties of high-viscosity poly(methyl-methacrylate) (PMMA) bone cement? Comparison between two different evacuation methods.

Authors:  E Fritsch; S Rupp; N Kaltenkirchen
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

5.  Curing characteristics of acrylic bone cement.

Authors:  N J Dunne; J F Orr
Journal:  J Mater Sci Mater Med       Date:  2002-01       Impact factor: 3.896

6.  Effect of shape on bone cement polymerization time in knee joint replacement surgery.

Authors:  Jung-Ro Yoon; Young-Rok Ko; Young-Soo Shin
Journal:  Medicine (Baltimore)       Date:  2018-04       Impact factor: 1.889

7.  Effect of storage temperature and equilibration time on polymethyl methacrylate (PMMA) bone cement polymerization in joint replacement surgery.

Authors:  Bryan T H Koh; J H Tan; Amit Kumarsing Ramruttun; Wilson Wang
Journal:  J Orthop Surg Res       Date:  2015-11-17       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.