| Literature DB >> 35774833 |
Naida Mulahuseinovic1, Lana Salihefendic1, Selma Durgut1, Enis Kandic1, Rijad Konjhodzic1.
Abstract
Background: SARS-CoV-2 is a coronavirus that causes a respiratory disease, COVID-19. For COVID-19 testing, real-time PCR is considered gold standard and therefore many commercial SARS-Cov-2 detection kits are available. Objective: The aim of the study is to determine diagnostic values of 10 different commercially available SARS-CoV-2 detection kits, based on their Ct value.Entities:
Keywords: Real-time PCR; SARS-CoV-2; SARS-CoV-2 detection kits
Year: 2022 PMID: 35774833 PMCID: PMC9233452 DOI: 10.5455/aim.2022.30.110-114
Source DB: PubMed Journal: Acta Inform Med ISSN: 0353-8109
PCR cycling conditions for SARS-CoV-2 detection kits
| UltraGene Combo2Screen SARS-CoV-2 Assay by ABL (Advanced Biological Laboratories) | |||
| Stage | Cycle | Temperature | Time |
| 1 (cDNA synthesis) | 1 | 70 | 5:00 |
| 2 (cDNA synthesis) | 1 | 93 | 0:03 |
| 3 (cDNA synthesis) | 1 | 67.5 | 2:30 |
| 4 (predanturation) | 1 | 93 | 0:03 |
| 5 (denaturation) | 1 | 66 | 2:30 |
| 6 (annealing and extension) | 40 | 95 | 00:10 |
| 58 | 00:15 | ||
| 72 | 00:15 | ||
| 7 (hold) | 1 | 40 | 00:01 |
| LabGunTM COVID-19 Assay by LabGenomics | |||
| Stage | Cycle | Temperature | Time |
| 1 (cDNA synthesis) | 1 | 50 | 30:00 |
| 2 (pre-denaturation) | 1 | 95 | 15:00 |
| 3 (denaturation) | 45 | 95 | 00:15 |
| 4 (nnealing and extension) | 60 | 1:00 | |
| LabGun COVID-19 ExoFast RT-PCR Kit by LabGenomics | |||
| Stage | Cycle | Temperature | Time |
| 1 (cDNA synthesis) | 1 | 50 | 5:00 |
| 2 (pre-denaturation) | 1 | 95 | 1:00 |
| 3 (denaturation) | 10 | 95 | 00:01 |
| 60 | 00:01 | ||
| 4 (annealing and extension) | 32 | 60 | 00:01 |
| 00:20 | |||
| 00:30 | |||
| 00:30 | |||
| PhoenixDx® SARS-CoV-2 Multiplex | |||
| Stage | Cycle | Temperature | Time |
| 1 (reverse transcription) | 1 | 50 | 05:00 |
| 2 (initial denaturation) | 1 | 95 | 05:00 |
| 3 (amplification) | 40 | 95 | 00:05 |
| 60 | 00:30 | ||
| DIAGNOVITAL® SARS-CoV-2 Real-Time PCR Kit by RTA Laboratories | |||
| Stage | Cycle | Temperature | Time |
| 1 (reverse transcription) | 1 | 45 | 20:00 |
| 2 (initial denaturation) | 1 | 95 | 10:00 |
| 3 (amplification) | 45 | 95 | 00:15 |
| 58 | 00:45 | ||
| Bosphore Novel Coronavirus (2019-nCoV) Detection Kit v2 by Anatolia Geneworks | |||
| Stage | Cycle | Temperature | Time |
| 1 (reverse transcription) | 1 | 50 | 17:00 |
| 2 (initial denaturation) | 1 | 95 | 06:00 |
| 3 (denaturation) | 35 | 97 | 00:30 |
| 4 (annealing) | 60 | 00:30 | |
| 5 (hold) | 1 | 32 | 02:00 |
| COVID-19 SARS-Cov-2 Real-TM by Saccace Biotechnologies | |||
| Stage | Cycle | Temperature | Time |
| 1 (cDNA synthesis) | 1 | 35 | 20:00 |
| 2 (pre-denaturation) | 1 | 94 | 05:00 |
| 3 (denaturation) | 5 | 94 | 00:25 |
| 64 | 00:10 | ||
| 4 (annealing and extension) | 45 | 94 | 00:25 |
| 64 | 00:10 | ||
| Bio-Speedy SARS-CoV-2 (2019-nCoV) qPCR Detection Kit by Bioeksen | |||
| Stage | Cycle | Temperature | Time |
| 1 (reverse transcription) | 1 | 52 | 05:00 |
| 2 (initial denaturation) | 1 | 95 | 00:10 |
| 3 (denaturation) | 40 | 95 | 00:01 |
| 4 (annealing and extension) | 55 | 00:30 | |
| STAT-NAT® COVID-19 MULTI by Sentinel Diagnostics | |||
| Stage | Cycle | Temperature | Time |
| 1 (reverse transcription) | 1 | 50 | 10:00 |
| 2 (initial denaturation) | 1 | 95 | 2:00 |
| 3 (denaturation) | 10 | 95 | 00:15 |
| 58 | 00:30 | ||
| 3 (denaturation) | 35 | 95 | 00:15 |
| 58 | 00:30 | ||
| SAVVYGEN™ SARS-COV-2 by Savyon diagnostics | |||
| Stage | Cycle | Temperature | Time |
| 1 (reverse transcription) | 1 | 45 | 15:00 |
| 2 (initial denaturation) | 1 | 95 | 2:00 |
| 3 (denaturation) | 45 | 95 | 00:10 |
| 4 (annealing) | 60 | 00:50 | |
Accuracy, sensitivity and specificity of used SARS-CoV-2 detection kits
| Name of the Kit | Accuracy % | Sensitivity % | Specificity % | Kappa coefficient |
|---|---|---|---|---|
| LabGun COVID-19 ExoFast RT-PCR Kit by LabGenomics | 80 | 75 | 100 | 0,54 |
| PhoenixDx® SARS-CoV-2 Multiplex | 87 | 83 | 100 | 0,67 |
| DIAGNOVITAL® SARS-CoV-2 Real-Time PCR Kit by RTA Laboratories | 83 | 79 | 100 | 0,6 |
| Bosphore Novel Coronavirus (2019-nCoV) Detection Kit v2 by Anatolia Geneworks | 76 | 70 | 100 | 0,5 |
| Bio-Speedy SARS-CoV-2 (2019-nCoV) qPCR Detection Kit by Bioeksen | 76 | 70 | 100 | 0,5 |
| UltraGene Combo2Screen SARS-CoV-2 Assay by ABL (Advanced Biological Laboratories) | 83 | 79 | 100 | 0,6 |
| COVID-19 SARS-Cov-2 Real-TM by Saccace Biotechnologies | 80 | 75 | 100 | 0,54 |
| Savvygen™ SARS-CoV-2 | 56 | 46 | 100 | 0,26 |
| STAT-NAT® COVID-19 MULTI | 87 | 83 | 100 | 0,67 |
Figure 1.Ct values summary of tested kits for SARS-CoV-2 detection
Figure 2.Obtained sensitivity of SARS-CoV-2 detection kits in group III