Literature DB >> 35763025

Buccal soft tissue dehiscence defects at dental implants-associated factors and frequency of occurrence: A systematic review and meta-analysis.

Ignacio Sanz-Martín1, Erik Regidor2, Jan Cosyn3, Daniel B Wiedemeier4, Daniel S Thoma5.   

Abstract

AIM: To identify the factors associated with buccal peri-implant soft tissue dehiscences (BSTDs) and their frequency of occurrence.
MATERIALS AND METHODS: Randomized controlled trials, controlled clinical trials, cohort studies, and case series assessing the frequency of occurrence of BSTD were included. BSTD was defined as an apical migration of the peri-implant soft tissues of ≥1 mm from the baseline examination (final restoration) or in comparison with the adjacent or contralateral natural tooth. Frequency distributions of BSTD related to the presence or absence of any surgical, prosthetic, or anatomic factor that may have contributed to the development of BSTD were recorded. Random-effects meta-analyses using odds ratios (OR) were performed to investigate the association of certain factors with the development of BSTD.
RESULTS: Twenty-four articles were finally included belonging to 22 clinical investigations. Patients at higher risk of developing BSTD were associated with thin biotype (OR = 2.85 [1.40, 5.8], n = 5, p = .003) and with buccally placed implants (OR = 14.37 [4.58, 45.14], n = 3, p ≤ .001). Patients without connective tissue grafting (CTG) had greater odds of developing BSTD (OR = 9.00 [3.11, 26.02], n = 5, p ≤ .001), while buccal bone plate thickness of <1 mm and immediately placed implants were not associated with greater BSTD (OR = 1.29 [0.35, 4.77], n = 2, p = .704 and OR = 1.56 [0.46, 5.26], n = 4, p = .477, respectively). The frequency of occurrence of BSTD varied across the included studies with a range from 0% to 61%.
CONCLUSIONS: Thin tissue biotype and buccally placed implants were associated with BSTD, whereas CTG seemed to have a protective effect. Thin buccal plates and immediately placed implants did not demonstrate a higher risk of BSTD.
© 2022 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implants; implant complications; soft tissue dehiscence; tissue deficiencies

Mesh:

Substances:

Year:  2022        PMID: 35763025     DOI: 10.1111/clr.13888

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  1 in total

1.  Consensus report of DGI/SEPA/Osteology Workshop.

Authors:  Mariano Sanz; Lisa Heitz-Mayfield
Journal:  Clin Oral Implants Res       Date:  2022-06       Impact factor: 5.021

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.