XiaoDong Wu1, ShuoDong Wu2, ShaoShan Tang3.
Abstract
BACKGROUND: The purpose of this retrospective study aimed to assess the accuracy of detection of remnant common bile duct (CBD) stones by injecting saline through endoscopic nasobiliary drainage (ENBD) tubes under transabdominal ultrasound (US) guidance.Entities:
Keywords: ENBD; ERCP remnant stone; Ultrasound
Mesh:
Year: 2022 PMID: 35761194 PMCID: PMC9238265 DOI: 10.1186/s12876-022-02394-8
Source DB: PubMed Journal: BMC Gastroenterol ISSN: 1471-230X Impact factor: 2.847
Baseline characters of included patients
| Occlusion cholangiogram/Routine Ultrasound/ENBD Injection ultrasound ( | ||
|---|---|---|
| Age (year) | 58.1 ± 15.6 | |
| Gender | Male | 154(51%) |
| Female | 148(49%) | |
| BMI (kg/m2) | 27.7 ± 0.7 | |
| History of cholecystectomy | 77(27%) | |
| Gallbladder stone | 193 (64%) | |
| Hepatolith | 39 (13%) | |
| Treatment method during ERCP | EST | 287(95%) |
| Balloon Dilation | 214(71%) | |
| Balloon extraction | 220(73%) | |
| Basket retrieval | 88 (29%) | |
| Lithotripsy | 18 (6%) | |
| ERCP duration (min) | 26 ± 8.6 | |
| LABS | Total bilirubin (umol/L) | 57.5 ± 6.0 |
| Direct bilirubin (umol/L) | 37.4 ± 4.8 | |
| Indirect bilirubin (umol/L) | 20.1 ± 2.0 | |
| Alkaline phosphatase (U/L) | 166.5 ± 10.8 | |
| ALT (U/L) | 151.0 ± 17.1 | |
| AST (U/L) | 103.5 ± 14.0 |
Fig. 1The examination results of patients
Fig. 2The examination results of patients
Comparison of the results of occlusion cholangiogram and ENBD saline injection ultrasound
| Occlusion cholangiogram | ENBD Injection ultrasound | |||
|---|---|---|---|---|
| Common bile duct | Length (mm) | 53.4 ± 1.50 | 62.62 ± 1.17 | < 0.001 |
| Diameter (mm) | 10.63 ± 0.474 | 10.36 ± 0.369 | 0.601 | |
| True positive individual | 26 | 46 | < 0.001 | |
| True negative individual | 246 | 247 | 0.689 | |
| False positive individual | 5 | 4 | 0.689 | |
| False negative individual | 25 | 5 | < 0.001 | |
| Specificity | 98.0% | 98.4% | 0.689 | |
| Sensitivity | 50.9% | 90.1% | < 0.001 | |
| False positive rate | 2.0% | 1.6% | 0.689 | |
| False negative rate | 49.1% | 9.9% | < 0.001 | |
| Estimated accuracy | 90.1% | 96.4% | < 0.001 |
Fig. 3Comparison between occlusion cholangiogram and ENBD saline injection in ultrasounds in a 78-year-old women. A. There are no significant stones found in occlusion cholangiogram. B. Remnant stone is found by ENBD saline injection ultrasound
Comparison of water injection results between normal ultrasound and ENBD saline-injection ultrasound
| Routine ultrasound | ENBD Injection ultrasound | |||
|---|---|---|---|---|
| Common bile duct | Length (mm) | 38.05 ± 1.87 | 62.62 ± 1.17 | 0.048 |
| Diameter (mm) | 6.959 ± 0.258 | 10.366 ± 0.369 | 0.034 | |
| Imaging degree of common bile duct | without imaging of Whole bile duct | 87(28.8%) | 7(2.3%) | < 0.001 |
| without imaging of upper part | 71(23.5%) | 7(2.3%) | < 0.001 | |
| without imaging of lower part | 136(45.0%) | 15(4.9%) | < 0.001 | |
| True positive individual | 12 | 46 | < 0.001 | |
| True negative individual | 250 | 247 | 0.249 | |
| False positive individual | 1 | 4 | 0.249 | |
| False negative individual | 39 | 5 | < 0.001 | |
| Specificity | 99.6% | 98.4% | 0.249 | |
| Sensitivity | 23.5% | 90.1% | < 0.001 | |
| False positiverate | 0.4% | 1.6% | 0.249 | |
| False negative rate | 76.5% | 9.9% | < 0.001 | |
| Estimated accuracy | 86.7% | 96.4% | < 0.001 |
Fig. 4Comparison between routine ultrasound and ENBD saline injection ultrasound in a 78-year-old women. A. The imaging length of CBD in ENBD saline injection ultrasound (right) is significantly longer than in routine ultrasound (left). B. Remnant stone in ENBD saline injection ultrasound found (right) that cannot be found in routine ultrasound (left)