Analysis of the effects of different surgical approaches on corporotomy localization in inflatable penile implant surgery performed by expert implant surgeons.

N L Lauwers1, K Van Renterghem2,3,4, D Osmonov5, A Suarez-Sarmiento6, P Perito6, S Park7, R Andrianne8, D Ralph9, I Mykoniatis10.   

Abstract

Inflatable penile prostheses may be a solution for patients with erectile dysfunction. To our knowledge, no data exist regarding the effect of different surgical approaches used during implantation on the site of the corporotomy. The main purpose of this multicentre study was to investigate the influence of different surgical approaches on the corporotomy site.Data were collected from six expert implant surgeons. Surgical notes were searched for the incision site, proximal, distal and total corporal length measurement, total cylinder length, length of rear tip extenders, surgery time, type of implant, and reservoir placement. The association between the proximal/distal corporal length and the recorded covariates was examined using a linear mixed model.A total of 1757 patients who underwent virgin prosthesis implantation were included in the analysis. Analysis of proximal/distal measurements was performed on 1709 patients. The proximal/distal ratio had a mean of 0.8 ± 0.3 in penoscrotal incisions (n = 391), 0.7 ± 0.2 in infrapubic incisions (n = 832) and 0.7 ± 0.2 in subcoronal (n = 486) incisions. We observed no significant differences in proximal/distal measurements between the highest-volume surgeons.We could not draw a firm conclusion about the difference in corporotomy site between different surgical approaches, but we found no significant difference between the highest-volume surgeons using different techniques.
© 2022. The Author(s), under exclusive licence to Springer Nature Limited.

Entities:  

Year:  2022        PMID: 35760888     DOI: 10.1038/s41443-022-00593-1

Source DB:  PubMed          Journal:  Int J Impot Res        ISSN: 0955-9930            Impact factor:   2.896


  2 in total

1.  The inflatable penile prosthesis: failure of the rear tip extender in reducing the incidence of cylinder leakage.

Authors:  J G Gregory; M H Purcell; J Standeven
Journal:  J Urol       Date:  1984-04       Impact factor: 7.450

2.  Minimally invasive infrapubic inflatable penile prosthesis implant for erectile dysfunction: evaluation of efficacy, satisfaction profile and complications.

Authors:  G Antonini; G M Busetto; E De Berardinis; R Giovannone; P Vicini; F Del Giudice; S L Conti; V Gentile; P E Perito
Journal:  Int J Impot Res       Date:  2015-12-10       Impact factor: 2.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.