Literature DB >> 35754520

Quantifying Distributions of Parameters for Cardiac Action Potential Models Using the Hamiltonian Monte Carlo Method.

Alejandro Nieto Ramos1, Conner J Herndon2, Flavio H Fenton2, Elizabeth M Cherry3.   

Abstract

Aims: Cardiac action potential (AP) models are typically given with a single set of parameter values; however, this approach does not consider variability and uncertainty across individuals and experimental conditions. As an alternative to single-value parameter fitting, we sought to use a Bayesian approach, the Hamiltonian Monte Carlo (HMC) algorithm, to find distributions of physiological parameter values for cardiac AP models across a range of cycle lengths (CLs) and dynamics.
Methods: To assess HMC's accuracy for cardiac data, we applied it to synthetic APs from the Mitchell-Shaeffer (MS) and Fenton-Karma (FK) models with added noise over a range of physiological CLs, some of which included alternans. To show the applicability of HMC to experimental data, we calculated parameter distributions for both models using micro-electrode recordings of zebrafish APs from a range of CLs.
Results: For synthetic APs generated from three CLs using the MS (FK) models, HMC produced unimodal quasi-symmetric distributions for all five (13) parameters. APs generated by setting all parameters in the MS (FK) model to the modes of their corresponding marginal distributions yielded errors in voltage traces below 5.0% (0.6%). We also obtained distributions for the MS (FK) model parameters using zebrafish data to construct the first minimal model of the zebrafish AP, with voltage trace errors below 4.8% (3.4%).
Conclusion: We have shown that HMC can identify not only a single set of parameter values but also viable distributions for cardiac AP model parameters using synthetic and experimental data. Because HMC generates samples from the parameter distributions based on input data, it can produce families of parameterizations that can be used in population-based modeling approaches without the need for rejecting a large number of randomly generated candidate parameterizations. HMC also has the potential to provide quantitative measures of spatial/individual variability and uncertainty.

Entities:  

Year:  2022        PMID: 35754520      PMCID: PMC9228588          DOI: 10.23919/cinc53138.2021.9662836

Source DB:  PubMed          Journal:  Comput Cardiol (2010)        ISSN: 2325-887X


  4 in total

1.  Vortex dynamics in three-dimensional continuous myocardium with fiber rotation: Filament instability and fibrillation.

Authors:  Flavio Fenton; Alain Karma
Journal:  Chaos       Date:  1998-03       Impact factor: 3.642

2.  A two-current model for the dynamics of cardiac membrane.

Authors:  Colleen C Mitchell; David G Schaeffer
Journal:  Bull Math Biol       Date:  2003-09       Impact factor: 1.758

3.  Comparing two sequential Monte Carlo samplers for exact and approximate Bayesian inference on biological models.

Authors:  Aidan C Daly; Jonathan Cooper; David J Gavaghan; Chris Holmes
Journal:  J R Soc Interface       Date:  2017-09       Impact factor: 4.118

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.