Yue Jia1, Yunlong Liao2, Houzhi Cai1. 1. International Collaborative Laboratory of 2D Materials for Optoelectronic Science & Technology of Ministry of Education, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China. 2. International Collaborative Laboratory of 2D Materials for Optoelectronic Science & Technology of Ministry of Education, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Abstract
TaS2 as transition metal dichalcogenide (TMD) two-dimensional (2D) material has sufficient unstructured bonds and large inter-layer spacing, which highly supports transporting and absorbing mercury ions. The structural characterizations and simulation data show that an SPR sensor with high sensitivity can be obtained with a TaS2 material-modified sensitive layer. In this paper, the role of TaS2 nanoparticles in an SPR sensor was explored by simulation and experiment, and the TaS2 layer in an SPR sensor was characterized by SEM, elemental mapping, XPS, and other methods. The application range of structured TaS2 nanoparticles is explored, these TaS2 based sensors were applied to detect Hg2+ ions at a detection limit approaching 1 pM, and an innovative idea for designing highly sensitive detection techniques is provided.
TaS2 as transition metal dichalcogenide (TMD) two-dimensional (2D) material has sufficient unstructured bonds and large inter-layer spacing, which highly supports transporting and absorbing mercury ions. The structural characterizations and simulation data show that an SPR sensor with high sensitivity can be obtained with a TaS2 material-modified sensitive layer. In this paper, the role of TaS2 nanoparticles in an SPR sensor was explored by simulation and experiment, and the TaS2 layer in an SPR sensor was characterized by SEM, elemental mapping, XPS, and other methods. The application range of structured TaS2 nanoparticles is explored, these TaS2 based sensors were applied to detect Hg2+ ions at a detection limit approaching 1 pM, and an innovative idea for designing highly sensitive detection techniques is provided.
The concentration of heavy metal mercury ions (Hg2+) in water is an important reference standard for people’s health, and the maximum concentration of Hg2+ allowed in an effluent is 7.5 pM. Water contaminated with mercury ions (Hg2+) and its detection is a global issue to be solved [1]. In the natural environment, Hg2+ exits in a stable state and might slowly accumulate in the food chain [2]. The existence of large amounts of Hg2+ may have a harmful effect on adult health and an even more harmful effect on the health of infants, foetuses, and lactating and pregnant women [3]. For instance, excess Hg2+ has a harmful effect on the digestive, immune, and nervous systems of an adult. It also causes severe harm to the stomach, lungs, and eyes of foetuses, and it may seriously damage them [4]. Hence, mercury pollution is considered a high risk to public safety and public health [5].In order to lower the harmful effects produced as a result of mercury pollution, researchers have focused on limiting the release of substances that contain Hg2+ and have produced an extraordinarily low discharge standard [6,7]. For example, the US EPA standard is approximately 200pM [8], Japan’s standard is 40 ng/g, and China’s is 0.05 μg/L. However, current Hg2+ detection methods face numerous challenges as a result of the low discharge limit. The traditional technologies that detect Hg2+ are atomic fluorescence spectroscopy (AFS), electrochemistry (EC), and surface plasmon resonance (SPR) [9,10,11,12,13,14,15,16]. Thus, very sensitive pollution detection for Hg2+ is necessary [17,18]. The commonly used SPR optical sensing technologies have several advantages, for example, simple operation, low cost, and good stability [19,20,21]. Recently, graphene and MoS2 based SPR sensors were used as sensing layer materials [22,23,24,25,26]. However, due to the limited availability or shortage of sensing materials on gold surfaces, the use of old-fashioned SPR techniques for detecting low concentrations of metal ions is a big challenge. It is important to address the trace mercury ion low adsorption on to the current available sensing materials such as graphene, etc. [27,28]. Hence, recent research directions have focused on how to detect trace mercury ions and have illustrated the TaS2-based SPR sensors sensing mechanism.The two-dimensional (2D) TaS2 material is currently a hot topic for researchers after the discovery of monolayer 1T-TaS2 [29,30]. TaS2 has a substantial potential for the removal of Hg2+, which has made it a perfect candidate for Hg2+ sensing [31,32,33,34,35]. By selecting the TaS2 material for a sensing layer as shown in Figure 1, a sensitive TaS2-based SPR biosensor was successfully fabricated to detect Hg2+, with TaS2 nanosheets as the sensing layer. This novel SPR sensor is compatible with the demands of trace Hg2+ detection, and these TaS2 based biosensors detection limit approaches 1 pM. It is evident from the results that the sufficient unsaturated bonds in the TaS2 structure and large interlayer spacing-based biosensors promote adsorption of Hg2+ and efficient transport.
Figure 1
TaS2 nanoflakes as the sensing layer to detect trace mercury ions in SPR sensors.
2. Experiment
2.1. Synthesis of Superstructure TaS2 Nanoflakes
The liquid phase stripping method was used to produce the 2D TaS2 material ethanol suspensions. Using ultrasound and a mixture of purified water, the TaS2 interlayer van der Waals force was overcome. Using a centrifuge, TaS2 dispersions were formed by removing the TaS2 block from single and multilayer TaS2. First, 20 mg TaS2 was dissolved in 20 mL water, and we treated the entire solution in bath sonication at a power up to 300 W for 10 h. Furthermore, we controlled the effective temperature of the bath sonication at approximately 10 °C. After the entire procedure, the acquired TaS2 suspension was centrifuged for one hour with a rotation rate of 5000 r/min, then left for 12h for natural settling. For the upper layer liquid using a rotation rate of 12,000 r/min, the final step was centrifuged for 40 min. The subsequent supernatant was made of several layers of TaS2 dispersion for use in the next experiments.
2.2. Assembling of TaS2 Nanoflakes
TaS2 nanoparticles accumulated on gold (Au) chips using a layer-by-layer technique. TaS2 nanoparticle solution and polyetherimide (PEI) alternately flowed past the cell, and finally the TaS2 layers were assembled by electrostatic adsorption. Surplus cations were washed by Milli-Q de-ionized water (18.2 MΩ cm) flowing past the cell. In each dipping period, the thickness increased, and the liquid current velocity was controlled to be lower than 1 mL/min to avoid separation of the finished films.
2.3. Mercury Ion Detection
Mercury ion in a water solution at concentrations from 10−12 M to 10−6 M as imitations of domestic water supply were prepared to systematically pass through SPR biosensor equipment. The buffer was domestic water. We washed the sample using ultra-pure water after immersing it in Hg2+ solutions for half an hour, and then spectrum signals were recorded. The detection signal was exported through a computer linked with a Kretschmann structure electrochemical in situ time resolved SPR sensor.
3. Results and Discussion
3.1. Numerical Simulation
The monolayer TaS2 thickness is 0.361 nm [36,37]. The incident wavelength is 633 nm. In order to simulate this sensor sensitivity, the transmission matrix method is used. Type BK7 glass was selected as coupling prism, and 50 nm Au film was chosen as the metal layer. Equations for the BK7 glass refractive index was obtained from references [38,39]. The Au refractive index is represented by the Drude–Lorentz model [39]. The Au film surface was covered by TaS2 to prevent Au from being oxidized in order to further enhance the sensibility of the designed sensors. The refractive index of TaS2 is 12.25 + 3.06i [40,41,42]. The sensitive medium refractive index is expressed as ns = 1.33 + Δn, whereas Δn designates the sensitive medium refractive index change caused by biological and chemical reaction.The transfer matrix method was used [43] to calculate the N-layer model incident TM-polarized light reflectivity. These layers are piled vertically to the direction of the BK7 glass coupling prism for these TaS2 allotrope sensors, and the name of each layer is selected using the dielectric constant (εk), thickness (dk) and refractive index (nk), separately.The transformation of the sensing medium might change the resonance angle (Δθ), where SR1 = Δθ/Δn represents the sensitivity [44]. The BK7 glass has a low refractive index coupling prism to use in these biosensors. Figure 1 shows a conventional Kretschmann structure SPR biosensor that has a metallic layer to activate SPP. By applying a BK7 glass prism, the resulting Au metal layer SPR biosensor sensitivity is 133°/RIU, as shown in Figure 2. For a biochemical sensor, this sensitivity is unsatisfied [45]. Utilizing 2D materials TMDCs TaS2, we have developed SPR biochemical sensors in the current paper to enhance the sensitivity of the sensors [46,47,48].
Figure 2
(a–e) Simulation change of reflectivity relative to incident angles with different numbers of TaS2 nanosheets; (f) variation of sensitivity with respect to the number of TaS2 nanosheets.
Figure 2a–e shows the changes of reflectivity versus the incident angle. The resonance angles of the TaS2 sensor shift to higher incidence angles at one layer and the sensitive media refractive indices increase. Sensitivity can be increased by using 2D TMDCs material TaS2-based biochemical sensors. Figure 2f shows the changes in sensitivity of TaS2 on the Au surface. It shows that the biosensor sensitivity increases and then decreases with the addition of TaS2 layers from 1 to 9; the highest sensitivity for TaS2 biosensors is 201°/RIU when the TaS2 layers accumulate to 8 layers. The most likely reason for the transformation is because the light utilization rate reduces with an increase in the number of TaS2 layers. Therefore, the number of TaS2 layers has an optimal value and cannot be increased unboundedly.From Table 1, we can see that TaS2-based Kretschmann structure SPR biosensors show an obviously improvement.
Table 1
Different 2D material sensing medium layers to improve biosensors.
2D Materials
Optimal Sensitivity
Maximum Sensitivity
Detection Limit
Ref.
Graphene oxide
91.1°/RIU
2715 nm/RIU
10−11 mol/L
[49,50]
MoS2
49.2°/RIU
0.64 μA/ppb
11.52 × 10−3 ppb
[51,52]
MoSe2
50.4°/RIU
2524 nm/RIU
3.5 nM
[53]
WS2
48.6°/RIU
2459 nm/RIU
3.3 nM
[54]
TaS2
201°/RIU
10.36°/μM
1 pM
Our work
3.2. Application of TaS2 Based SPR Biosensors in Heavy Metal Ion Detection
The simulation results discussed in the last section provide details for depositing TaS2 nanoparticles onto SPR chip surfaces. First, using layer-by-layer (LBL) techniques, we assembled the as-prepared TaS2 nanosheets onto the SPR chip Au surface. Subsequently, using scanning electron microscopy (SEM), the surface morphology of TaS2 nanosheets over the SPR chips was characterized, as shown in Figure 3. By increasing the dipping cycle, TaS2 nanosheets were more thickly deposited, as shown in Figure 3a–c. Unexpectedly, it was observed that the morphology of the TaS2 nanosheets was not affected by the LBL process, as can be seen in the right side of Figure 3a–c. Thus, assembly of TaS2 nanosheets over SPR chip surfaces can be tuned by LBL assembly techniques. We have obtained SPR curves through different layers as the superstructure TaS2 materials were assembled via LBL method.
Figure 3
(a–c) The SEM images of the superstructure TaS2 nanoparticles assembled with different thicknesses were obtained for 1 μm scale bar on the SPR chip surface. The panels on the right side are the magnified images, with a scale bar of 100 nm.
We have prepared SPR sensors with chips coated with TaS2 nanosheets that, using SEM, can be seen to detect heavy metal ions. SPR spectra for different mercury ion concentrations from 10−12 M to 10−6 M were obtained, as shown in Figure 4a. We have identified the obvious shift curve toward higher resonance, which shows the Hg2+ adsorption onto the sensing layer material. The Hg2+ detection limit value in the calibration curve for the SPR angle shift versus Hg2+ concentration, from 10−12 M to 10−6 M Hg2+ solution concentration, 1 pM, were found to be the SPR sensor detection range [55]. This method’s detection limit was 200 times lower compared with other techniques [56,57,58]. Figure 4b displays the SPR sensors calibration curve of angle shift along with mercury ion concentration without TaS2 material, which is also in the range of 10−12–10−6, and the SPR spectra do not have much diversification. Figure 4c shows the incident angle changes for mercury ion concentrations from 10−12 M to 10−6 M; after linear fitting, we get a sensitivity of 10.36°/μM.
Figure 4
(a) The TaS2 SPR spectra at different concentrations of Hg2+ from 10−12 to 10−6 M; (b) SPR spectra without TaS2 at different concentrations of Hg2+ from 10−12 to 10−6 M; (c) the fitting curve of the incident angle at different concentrations of Hg2+ from 10−12 to 10−6 M; (d) selectivity of these TaS2 based Hg2+ sensors.
Apart from detecting Hg2+ in everyday drinking water, we also calculated the SPR sensor selectivity through investigating their responses to other heavy metal ions, for instance, Cr3+, Cr6+, Ag2+, Pb2+, Cu2+, and Cd2+. Under the same conditions, the response of the SPR sensors to dissimilar interfering ions at a level of 10−6 M concentration is shown in Figure 4d. In order to prevent the interference of an ion, we detected six different salts using the same concentration. The signal response ∆θ of the six cations were similarly low, nearly 100 mdeg on the same 10−6 M concentrations. The results reveal that the SPR sensors have a strong selectivity to mercury ions compared with the other metal ions.
3.3. Study of the Mechanism of High Sensitivity of These SPR Biosensors
The mechanism of the sensitivities of these TaS-based SPR sensors to detect Hg2+ was measured using elemental mapping of TaS2 nanoflakes. Shown in the Figure 5, the elemental mapping characterizations of superstructure TaS2 nanosheets by STEM EDS are displayed. Figure 5a shows a STEM image of TaS2 nanoparticles; in the same way Figure 5b–d reveal Ta, S, and Ta + S EDS elemental maps. The distance between the layers of TaS2 nanosheets is large, which is favourable for Hg2+ to enter the inner space where S atoms as binding sites are most likely located. These features allow the use of these TaS2 nanosheets to detect Hg2+ in SPR sensors.
Figure 5
Elemental mapping characterizations of superstructure TaS2 nanosheets by STEM EDS. (a) STEM image of TaS2 nanosheets, similarly acquired with (b–d) Ta, S, and Ta + S EDS elemental maps.
To get a clear picture of these highly sensitivity SPR sensors, we used the ESCALAB-250 instrument to measure X-ray photoelectron spectroscopy (XPS) in order to analyse the chemical states of Ta and S in structured TaS2 nanoparticles and the original TaS2 block. From Figure 6a, it is clear that two characteristic peaks of 167.1 eV and 168.4 eV are accredited to the 2p2/3 and 2p1/2 energy levels of divalent sulphide ions. Figure 6b, on the left side, illustrates that, at low intensity, the peak at 163.7 eV may be attributed to bridging S2-, which represents unsaturated S atoms. The Ta 3d spectra of the TaS2 powder are demonstrated by the peaks at 404.5 eV and 466.3 eV, corresponding to binding energies of Ta 4p3/2 and Ta 4d1/2, respectively (Figure 6a,b), which suggests the presence of TaS2 structure 422.3 eV is the loss of Ta.
Figure 6
(a) XPS spectra of bulk TaS2; (b) XPS spectra of TaS2 nanoflakes.
The left side of Figure 6b shows new peaks, which suggests the occurrence of the TaS2 structure. The atomic configuration of TaS2 is very dense on the surface of the substrate and also has a very high electronic conductivity, thus facilitating the combination of Hg2+. In TaS2 nanoflakes, the increased sensitivity of Hg2+ in the SPR sensor is promoted by the unsaturated S atoms.
4. Conclusions
Innovative SPR biochemical sensors using 2D TMDCs TaS2 were designed and constructed to enhance the sensitivity to Hg2+ ions. The proposed design has improved the sensitivity of biochemical sensors to 201°/RIU for TaS2. The SPR sensor was developed, and its performance was evaluated through a combination of simulation and experimental results. The detection sensitivity limit of TaS2-based SPR biosensors is nearly 1 pM. TEM, HRTEM, and XPS were used to investigate the mechanism of these highly sensitive SPR sensors. From the obtained results, having a large inter-layer spacing and sufficient non-structural combination in the proposed TaS2-based structure makes Hg2+ effectively transported and absorbed. These studies provide efficient methods for the detection of low Hg2+ concentrations and generalize the utilization of structured TaS2 nanosheets.