Literature DB >> 3572773

Anterior chamber lenses. Part II: A laboratory study.

D J Apple, S O Hansen, S C Richards, G W Ellis, D Kavka-Van Norman, M R Tetz, B R Pfeffer, R B Park, A S Crandall, R J Olson.   

Abstract

An analysis of 606 surgically removed anterior chamber intraocular lens (IOL) specimens revealed that 351 or 58% of these were small-diameter, round loop, closed-loop styles. Because of the extremely high percentage of IOLs with this design received in our laboratory and the correlation of clinical histories with our histopathologic findings, we have concluded that such IOLs do not provide the safety and efficacy achieved by other anterior chamber lens designs. The finely polished, one-piece, all-PMMA styles fared well in our study. Although these one-piece styles comprise well over 50% of the American market share of anterior chamber IOLs, they comprise only 14% of all anterior chamber IOLs accessioned in our laboratory, compared to 58% for closed-loop designs. We believe that implantation of anterior chamber lenses with small-diameter, round, closed loops is no longer warranted. Patients in whom these IOLs have already been implanted should be carefully followed. It is our opinion that the FDA should recall or closely monitor all IOLs of this design and that implantation of closed-loop lenses should be discontinued in the United States. Furthermore, we believe that an IOL deemed to be not medically sound or worthy of implantation in the United States should not be marketed or donated outside of this country.

Entities:  

Mesh:

Year:  1987        PMID: 3572773     DOI: 10.1016/s0886-3350(87)80132-3

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

Authors:  S Kazemi; W J Wirostko; S Sinha; W F Mieler; S B Koenig; B P Sheth
Journal:  Trans Am Ophthalmol Soc       Date:  2000

2.  [History of the development of intraocular lenses].

Authors:  G U Auffarth; D J Apple
Journal:  Ophthalmologe       Date:  2001-11       Impact factor: 1.059

3.  Refractive surgery for high myopia. The Worst-Fechner biconcave iris claw lens.

Authors:  J G Worst; G van der Veen; L I Los
Journal:  Doc Ophthalmol       Date:  1990-10       Impact factor: 2.379

4.  A spontaneous protruded angle-supported anterior chamber intraocular lens: A case report.

Authors:  Hsin-Le Lin; Gow-Lieng Tseng
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

5.  Anterior chamber fixation of a posterior chamber intraocular lens: a novel technique.

Authors:  A Sahap Kükner; Gürsoy Alagöz; Mesut Erdurmus; Didem Serin; Umit Dogan; Turgut Yilmaz
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.