| Literature DB >> 35725820 |
María Sánchez Conejero1, Jesús González de Buitrago Amigo2, María Luz Tejado Bravo1, Jorge M de Nicolás Jiménez3.
Abstract
BACKGROUND AND AIMS: To face the rapid spread of SARS-CoV2 coronavirus pandemic, home lockdown in Spain was decreed on 15th March 2020. The main objective of this study is to evaluate the impact of this constraint on glycemic control in children and adolescents with type 1 diabetes mellitus (T1D). PATIENTS AND METHODS: Observational, retrospective study in children and adolescents with T1D users of interstitial glucose monitoring systems. The following information corresponding to the last 2 weeks of lockdown was collected for subsequent comparison with data of 2 weeks prior to quarantine: daily insulin needs, mean interstitial glucose, estimated HbA1c, coefficient of variation (CV), time in range (70-180mg/dl), hypoglycemia (<70 and <54mg/dl) and hyperglycemia (>180 and> 250mg/dl), sensor use and number of blood glucose measurements. Data about meal routines, physical exercise, need for adjustments in therapy, acute complications and lockdown of caregivers were assessed via a survey.Entities:
Keywords: COVID-19; Confinamiento; Continuous glucose monitoring; Control glucémico; Covid-19; Diabetes tipo 1; Edad pediátrica; Flash glucose monitoring; Glycemic control; Lockdown; Monitorización continua de glucosa; Monitorización flash de glucosa; Pediatric age; Type 1 diabetes
Mesh:
Substances:
Year: 2022 PMID: 35725820 PMCID: PMC9186430 DOI: 10.1016/j.anpede.2020.12.022
Source DB: PubMed Journal: An Pediatr (Engl Ed) ISSN: 2341-2879
Comparison of CGM/FGM parameters before and during the confinement in the total sample.
| n = 80 | Pre-confinement | Confinement | |
|---|---|---|---|
| Mean glucose, monitoring (mg/dL) | 145.4 ± 12.9 | 145.4 ± 13.8 | NS |
| Estimated HbA1c (%) | 6.69 ± 0.44 | 6.67 ± 0.44 | NS |
| Coefficient of variation (%) | 35.8 ± 6.3 | 33.1 ± 6.1 | <.001 |
| Time in range 70–180 mg/dL (%) | 72.1 ± 10.5 | 74.8 ± 10.5 | .011 |
| Time > 180 mg/dL (%) | 23.5 ± 9.8 | 22.0 ± 10.0 | NS |
| Time > 250 mg/dL (%) | 4.6 ± 3.9 | 3.7 ± 3.7 | .038 |
| Time < 70 mg/dL (%) | 4.6 ± 3.2 | 3.2 ± 2.7 | <.001 |
| Time < 54 mg/dL (%) | 1.2 ± 1.6 | 0.7 ± 1.2 | <.001 |
| Use of monitoring system (%) | 90.2 ± 10.7 | 89.6 ± 12.5 | NS |
Data expressed as mean ± standard deviation.
NS: not significant.
Comparison of CGM/FGM parameters before and during the confinement in patients treated with multiple insulin injection (MDI) y con continuous subcutaneous insulin infusion (CSII).
| MDI (n = 27) | CSII (n = 53) | |||||
|---|---|---|---|---|---|---|
| Pre-confinement | Confinement | Pre-confinement | Confinement | |||
| Mean glucose, monitoring (mg/dL) | 150.3 ± 13.4 | 147.0 ± 16.0 | NS | 142.9 ± 12.0 | 144.5 ± 12.5 | NS |
| Estimated HbA1c (%) | 6.87 ± 0.43 | 6.75 ± 0.49 | NS | 6.60 ± .42 | 6.64 ± .41 | NS |
| Coefficient of variation (%) | 38.3 ± 7.2 | 34.9 ± 6.9 | <.001 | 34.5 ± 5.3 | 32.2 ± 5.5 | .005 |
| Time in range 70–180 mg/dL (%) | 67.6 ± 11.6 | 70.1 ± 13.0 | .018 | 74.5 ± 9.2 | 76.8 ± 8.5 | NS |
| Time > 180 mg/dL (%) | 27.5 ± 10.0 | 24.5 ± 12.3 | NS | 21.4 ± 9.1 | 2.8 ± 8.3 | NS |
| Time > 250 mg/dL (%) | 6.6 ± 4.4 | 4.9 ± 4.4 | .011 | 3.6 ± 3.3 | 3.3 ± 3.4 | NS |
| Time < 70 mg/dL (%) | 5.5 ± 4.1 | 4.5 ± 3.8 | NS | 4.1 ± 2.5 | 2.4 ± 1.7 | <.001 |
| Time < 54 mg/dL (%) | 1.6 ± 2.0 | 1.3 ± 1.8 | NS | 1.0 ± 1.2 | .3 ± .5 | <.001 |
| Use of monitoring system (%) | 95.7 ± 7.1 | 97.1 ± 4.7 | NS | 87.3 ± 11.2 | 85.7 ± 13.5 | NS |
Data expressed as mean ± standard deviation.
NS: not significant.
Comparison of CGM/FGM parameters before and during the confinement in patients with a baseline estimated HbA1c of < 7% versus ≥ 7%.
| HbA1c < 7% (n = 62) | HbA1c ≥ 7% (n = 18) | |||||
|---|---|---|---|---|---|---|
| Pre-confinement | Confinement | Pre-confinement | Confinement | |||
| Mean glucose, monitoring (mg/dL) | 140.0 ± 8.2 | 143.9 ± 14.0 | .029 | 163.9 ± 8.2 | 15.5 ± 11.9 | .001 |
| Estimated HbA1c (%) | 6.52 ± 0.29 | 6.62 ± 0.44 | NS | 7.30 ± .28 | 6.86 ± .37 | .002 |
| Coefficient of variation (%) | 35.2 ± 6.4 | 32.4 ± 6.4 | <.001 | 37.8 ± 5.4 | 35.5 ± 4.3 | .028 |
| Time in range 70–180 mg/dL (%) | 75.7 ± 8.8 | 76.1 ± 10.7 | NS | 6.0 ± 6.2 | 7.7 ± 8.9 | .001 |
| Time > 180 mg/dL (%) | 19.7 ± 6.9 | 20.9 ± 10.1 | NS | 36.7 ± 6.3 | 26.0 ± 8.7 | .003 |
| Time > 250 mg/dL (%) | 3.2 ± 2.8 | 3.4 ± 3.7 | NS | 9.5 ± 3.7 | 5.5 ± 3.9 | .001 |
| Time < 70 mg/dL (%) | 4.8 ± 3.2 | 3.1 ± 2.9 | <.001 | 3.7 ± 2.8 | 3.4 ± 2.1 | NS |
| Time < 54 mg/dL (%) | 1.2 ± 1.6 | 0.7 ± 1.3 | .001 | 1.1 ± 1.5 | .7 ± 1.0 | NS |
| Use of monitoring system (%) | 89.7 ± 10.6 | 89.4 ± 12.4 | NS | 91.9 ± 11.3 | 9.3 ± 12.9 | NS |
Data expressed as mean ± standard deviation.
NS: not significant.
Comparison of CGM/FGM parameters before and during the confinement in patients with a baseline time in range (70–180 mg/dL) > 70% vs ≤ 70%.
| Time in range > 70% (n = 42) | Time in range ≤ 70% (n = 38) | |||||
|---|---|---|---|---|---|---|
| Pre-confinement | Confinement | Pre-confinement | Confinement | |||
| Mean glucose, monitoring (mg/dL) | 136.6 ± 7.4 | 140.6 ± 13.8 | .045 | 155.1 ± 1.6 | 15.4 ± 12.0 | NS |
| Estimated HbA1c (%) | 6.39 ± 0.26 | 6.51 ± 0.43 | NS | 7.03 ± .34 | 6.86 ± .38 | NS |
| Coefficient of variation (%) | 32.5 ± 5.0 | 30.6 ± 5.8 | .023 | 39.4 ± 5.5 | 35.9 ± 5.1 | <.001 |
| Time in range 70–180 mg/dL (%) | 80.4 ± 6.1 | 79.8 ± 9.2 | NS | 63.1 ± 5.9 | 69.4 ± 9.2 | .001 |
| Time > 180 mg/dL (%) | 16.3 ± 5.6 | 17.9 ± 9.2 | NS | 31.5 ± 6.8 | 26.6 ± 8.7 | .032 |
| Time > 250 mg/dL (%) | 1.9 ± 1.5 | 2.2 ± 2.9 | NS | 7.6 ± 3.6 | 5.6 ± 3.8 | .005 |
| Time < 70 mg/dL (%) | 3.6 ± 2.3 | 2.4 ± 2.6 | .003 | 5.7 ± 3.6 | 4.0 ± 2.6 | .001 |
| Time < 54 mg/dL (%) | 0.6 ± 0.8 | 0.4 ± 0.9 | NS | 1.9 ± 1.9 | 1.0 ± 1.4 | .001 |
| Use of monitoring system (%) | 90.4 ± 11.5 | 89.9 ± 12.9 | NS | 89.9 ± 9.9 | 89.3 ± 12.2 | NS |
Data expressed as mean ± standard deviation.
NS: not significant.