Figure 1Schematic representation of gap-filler method for mechanical bileaflet valve closure. A, Key diameter measurements of St Jude Medical Regent valve. a, Tissue annulus diameter. b, Valve orifice inner diameter. c, Diameter of gap in closed position between orifice ring and edge of leaflet. B, Placement of double-layered polytetrafluoroethylene felt circular patch. C, Gap filled with patch.
Figure 2A, Four polytetrafluoroethylene circular felt patches, 2 large (diameter, 26 mm) and 2 small (diameter, 22 mm), were fashioned. Determination of the size of the large patch was based on the size of the implanted prosthesis graft. B, Patches of the same size were sutured together with a 4–0 Prolene stitch. C, The smaller patches were then sutured to the larger patches using 3 4–0 Prolene stiches. D, The resultant gap-filler patch was inserted into the inner orifice area of the valve.