A dissection … of the Dacron?

John M Trahanas1, Omar A Jarral1, G Chad Hughes1.   

Abstract

Entities:  

Year:  2022        PMID: 35711195      PMCID: PMC9196977          DOI: 10.1016/j.xjtc.2022.03.022

Source DB:  PubMed          Journal:  JTCVS Tech        ISSN: 2666-2507


× No keyword cloud information.
Aorta at 9 and 13 months postoperatively showing pseudointimal Dacron graft dissection. Dacron grafts develop a pseudointima as endothelial cells repopulate the wall of the graft. This can be undermined and elevated in a similar manner to native intima, appearing like a dissection flap. Treatment for ascending aneurysm is replacement with a Dacron graft to reduce lifetime risk of acute aortic syndrome. While pseudoaneurysms may develop at graft suture lines, typically the replaced segment of aorta is spared from future dissection. We recently encountered a case that demonstrated this may not always be true. A 64-year-old female patient was referred for Bicuspid Aortic Valve syndrome including a 7.1-cm ascending aortic/proximal arch aneurysm and severe aortic insufficiency with dilated cardiomyopathy. The subject provided informed written consent for the publication of their study data; institutional review board approval was not required. She underwent bioprosthetic aortic valve replacement and ascending aorta/hemiarch replacement using a 30-mm Gelweave Dacron graft (Vascutek). She was started on routine aspirin monotherapy from the first postoperative day. She had an unremarkable recovery and was seen back for routine surveillance imaging 9 months postoperatively, at which time an apparent dissection flap was seen in her Dacron graft. As the patient was asymptomatic and the flap limited to the Dacron-replaced segment with no involvement of native aorta, we thought the finding might represent motion artifact on the nongated computed tomography angiography study. A gated computed tomography angiography was therefore ordered but not obtained until 4 months later due to pandemic-related delay. The repeat study demonstrated an identical finding (Figure 1, Figure 2, Figure 3 and Video 1), thereby ruling out motion artifact. The flap measured 62 mm in length, 30 mm in width, and 2 mm in thickness.
Figure 1

Coronal reconstruction computed tomography angiography images of the aorta at 9 (left panel) and 13 (right panel) months postoperatively demonstrating pseudointimal Dacron graft dissection. Note that the pseudointimal flap is limited to the Dacron-replaced segment of aorta.

Figure 2

Axial computed tomography angiography images of the aorta at 9 (left panel) and 13 (right panel) months post-operatively demonstrating stable pseudointimal Dacron graft dissection.

Figure 3

Postoperative 3-dimensional computed tomography angiography reconstruction of the aorta with pseudointimal flap in Dacron-replaced segment indicated (arrow).

Coronal reconstruction computed tomography angiography images of the aorta at 9 (left panel) and 13 (right panel) months postoperatively demonstrating pseudointimal Dacron graft dissection. Note that the pseudointimal flap is limited to the Dacron-replaced segment of aorta. Axial computed tomography angiography images of the aorta at 9 (left panel) and 13 (right panel) months post-operatively demonstrating stable pseudointimal Dacron graft dissection. Postoperative 3-dimensional computed tomography angiography reconstruction of the aorta with pseudointimal flap in Dacron-replaced segment indicated (arrow). How did this happen? Dacron grafts develop a pseudointima as endothelial cells repopulate the wall of the graft. Review of the literature revealed several previously reported cases of this pseudointima being undermined and elevated by the blood column in a similar manner to native intima. Although not present in the current case, the pseudointimal flap may cause obstruction, which has been previously described in replaced segments of descending/abdominal aorta.2, 3, 4 The interval between surgery and diagnosis in these previously reported cases ranged from 2 to 25 years. To our knowledge, pseudointimal dissection has not been described in Dacron-replaced ascending aorta until now. In addition to confusing imaging findings, pseudointimal dissection has been implicated as the cause of embolic events. Our patient remains asymptomatic and clinically well now 3 years postoperatively, continuing on aspirin monotherapy.
  4 in total

1.  The pseudointima lining fabric grafts of the aorta.

Authors:  H W FLOREY; S J GREER; J C POOLE; N T WERTHESSEN
Journal:  Br J Exp Pathol       Date:  1961-06

2.  Pseudointimal embolism from a woven Dacron graft.

Authors:  J W Stratton; R V Hall
Journal:  Surgery       Date:  1979-11       Impact factor: 3.982

3.  Dacron graft aneurysm with dissection.

Authors:  Asik Ali Mohamed Ali; Praveen Sharma; Rujuta N Rege; Saveetha Rajesh; Kulasekaran Nadhamuni
Journal:  Indian J Radiol Imaging       Date:  2016 Oct-Dec

4.  Management of re-coarctation due to prosthetic graft pseudo-intimal dissection.

Authors:  Maninder S Kalkat; Sara A Thorne; Peter Guest; Robert S Bonser
Journal:  Interact Cardiovasc Thorac Surg       Date:  2006-11-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.