BACKGROUND: Coronary 18F-sodium-fluoride (18F-NaF) positron emission tomography (PET) showed promise in imaging coronary artery disease activity. Currently image processing remains subjective due to the need for manual registration of PET and computed tomography (CT) angiography data. We aimed to develop a novel fully automated method to register coronary 18F-NaF PET to CT angiography using pseudo-CT generated by generative adversarial networks (GAN).
METHODS: A total of 169 patients, 139 in the training and 30 in the testing sets were considered for generation of pseudo-CT from non-attenuation corrected (NAC) PET using GAN. Non-rigid registration was used to register pseudo-CT to CT angiography and the resulting transformation was used to align PET with CT angiography. We compared translations, maximal standard uptake value (SUVmax) and target to background ratio (TBRmax) at the location of plaques, obtained after observer and automated alignment.
RESULTS: Automatic end-to-end registration was performed for 30 patients with 88 coronary vessels and took 27.5 seconds per patient. Difference in displacement motion vectors between GAN-based and observer-based registration in the x-, y-, and z-directions was 0.8 ± 3.0, 0.7 ± 3.0, and 1.7 ± 3.9 mm, respectively. TBRmax had a coefficient of repeatability (CR) of 0.31, mean bias of 0.03 and narrow limits of agreement (LOA) (95% LOA: - 0.29 to 0.33). SUVmax had CR of 0.26, mean bias of 0 and narrow LOA (95% LOA: - 0.26 to 0.26).
CONCLUSION: Pseudo-CT generated by GAN are perfectly registered to PET can be used to facilitate quick and fully automated registration of PET and CT angiography.
© 2022. The Author(s) under exclusive licence to American Society of Nuclear Cardiology.

Entities:  

Keywords:  CT; PET; image analysis; image reconstruction; multimodality

Year:  2022        PMID: 35701650     DOI: 10.1007/s12350-022-03010-8

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  1 in total

1.  Feasibility of Coronary 18F-Sodium Fluoride Positron-Emission Tomography Assessment With the Utilization of Previously Acquired Computed Tomography Angiography.

Authors:  Jacek Kwiecinski; Philip D Adamson; Martin L Lassen; Mhairi K Doris; Alastair J Moss; Sebastian Cadet; Maurits A Jansen; Damini Dey; Sang-Eun Lee; Mijin Yun; Hyuk-Jae Chang; Marc R Dweck; David E Newby; Daniel S Berman; Piotr J Slomka
Journal:  Circ Cardiovasc Imaging       Date:  2018-12       Impact factor: 7.792

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.