Abstract
Background and objective: In surgical dentistry, shape, location, position, and extent of the anterior loop of mental foramen plays a deliberately imperative landmark during an osteotomy procedure. To evade any neurological disturbance during implant surgery radiological assessment is compulsory. Therefore, the aim of the study was to assess the position and level of mental nerve for placement of implants using Cone-beam computed tomography & Panoramic radiography in the Saudi population. Materials and methods: A total of 150 CBCT and Panoramic radiographs were taken from the patients who visited the Department of Oral Medicine and Radiology. The data collection was done by using the same radiographic pieces of equipment for both CBCT and Panoramic radiographs. CBCT images taken from Kodak 9000 3D, Carestream Health, Inc., New York, USA, and Panoramic Radiographs taken from Panoramic Planmeca ProMax, Helsinki, Finland (Vujanovic-Eskenazi et al., 2015). The Chi-square test student test was used for statistical analysis.Entities:
Keywords: CBCT; Dental implant; Inferior alveolar nerve; Mental nerve; Panoramic radiograph
Year: 2022 PMID: 35692242 PMCID: PMC9177872 DOI: 10.1016/j.sdentj.2022.04.001
Source DB: PubMed Journal: Saudi Dent J ISSN: 1013-9052
Fig. 1Measurement of Mental loop A) PR view, B) CBCT.
Mental foramen shape on right and left side in Cone Beam Computed Tomography (CBCT) & Panoramic Radiographic (PR) views.
| Right Side Shape | p value | Left Side Shape | p value | |||||
|---|---|---|---|---|---|---|---|---|
| CBCT | 20 | 55 | 0 | 0.119 | 18 | 57 | 0 | 0.119 |
| Panoramic | 21 | 50 | 04 | 19 (25.33%) | 52 (69.33%) | 04 (5.33%) | ||
Note:-Results are presented as frequency distribution and Chi-square test was applied. P value < 0.005 consider significant.
Position of mental foramen of right side in Cone Beam Computed Tomography (CBCT) & Panoramic Radiographic (PR) views.
| Position of Mental foramen (Right Side) | p value | ||||||
|---|---|---|---|---|---|---|---|
| CBCT | 0 | 0 | 36 (48%) | 33 (44%) | 04 (5.33%) | 02 (2.66%) | |
| Panoramic | 0 | 0 | 39 (52%) | 32 (42.66%) | 03 (4%) | 01 (1.33%) | |
Note:-Results are presented as frequency distribution and Chi-square test was applied. P value < 0.005 consider significant.
Position of mental foramen of right side in Cone Beam Computed Tomography (CBCT) & Panoramic Radiographic (PR) views.
| Position of Mental foramen (Left Side) | p value | ||||||
|---|---|---|---|---|---|---|---|
| CBCT | 01(1.33%) | 0 | 38(50.66%) | 27(36%) | 07(9.33%) | 02(2.66%) | |
| Panoramic | 01(1.33%) | 0 | 36(48%) | 33(44%) | 03(4%) | 02(2.66%) | |
Note:-Results are presented as frequency distribution and Chi-square test was applied. P value < 0.005 consider significant.
Mental loop visibility on Cone Beam Computed Tomography (CBCT) & Panoramic Radiographic (PR) View.
| Visibility | p value | ||
|---|---|---|---|
| CBCT | 42(56%) | 33(44%) | |
| Panoramic | 26(34.66%) | 49(65.33%) | |
Note:-Results are presented as frequency distribution and Chi-square test was applied. P value < 0.005 consider significant.
Mean values of deviation of the mental loop (ML) and the distance of the mental foramen (MF) and the lower border of the mandible on panoramic radiographies (PR) and cone beam computed tomography (CBCT).
| Mean ± SD | p value | |
|---|---|---|
| Mental loop on CBCT | 1.609 ± 0.861 | |
| Mental loop on Panoramic | 2.567 ± 0.881 | |
| Distance between ML and basilar mandible on CBCT | 11.537 ± 2.677 | |
| Distance between ML and basilar mandible on PR | 11.68 ± 2.288 |
Note:-Results are presented as Mean and Standard Deviation and Student-t test was applied. P value < 0.005 consider significant.