Analysis of Artifacts on MRI from Electronic Identification Enablement in Silicone Gel Implants.

Alexandre Mendonça Munhoz1,2,3.   

Abstract

Entities:  

Year:  2022        PMID: 35685749      PMCID: PMC9169992          DOI: 10.1097/GOX.0000000000004366

Source DB:  PubMed          Journal:  Plast Reconstr Surg Glob Open        ISSN: 2169-7574


× No keyword cloud information.

Sir:

We read with interest the article by Kurz et al,[1] in which they express their concerns regarding the balance between the benefits and drawbacks of radio frequency identification device (RFID)-enabled breast implants. As indicated, this technology represents a higher level of traceability. Unlike typical product cards, the code in the RFID can never be lost or misplaced, providing accurate device tracking and identification.[2,3] Studies during the Poly Implant Prothèse product recall showed that almost one in four women lacked device information to determine they were at risk, an avoidable flaw with this 100% accurate and noninvasive option.[4] Moreover, with immediate access to implant information, surgeons can improve preoperative planning for revision surgery. Having the implant details before the procedure aids in appropriate sizing, procedure planning, and improved outcomes.[3] Kurz et al[1] acknowledge the benefits that come with RFID technology but are legitimately concerned by the presence of artifacts on the magnetic resonance imaging (MRI) due to the metallic ferrite core. In fact, artifacts associated with metal are a known impact due to magnetic susceptibility differences between substances. These can be minimized by strategically selecting the pulse sequence (Fig. 1) or simple considerations, such as increasing the frequency encoding bandwidth or reducing the slice thickness. In this context, it is fundamental to establish anatomical and methodological precisions and appropriately determine whether MRI for early cancer detection or surveillance is a recommended practice.[2]
Fig. 1.

Comparison of a silicone only (left) and a turbo spin-echo T2-weighted sequence (right), showing substantial artifact reduction. A, silicone gel implant; B, RFID microchip; C, area of the RFID artifact; and D, breast tissue.

Comparison of a silicone only (left) and a turbo spin-echo T2-weighted sequence (right), showing substantial artifact reduction. A, silicone gel implant; B, RFID microchip; C, area of the RFID artifact; and D, breast tissue. Screening or breast imaging surveillance is consistently recommended. However, MRI is not the front-line modality, and is supplemental only in high-risk groups.[5] Full-field digital mammography and digital breast tomosynthesis have been progressively adopted as the modality of choice for breast cancer screening, and adding ultrasound to any of the previous improves cancer detection rate.[4] Another consideration is that the breast tissue is anterior to the breast implant, and the RFID-related artifact is in the back of the implant, consequently impacting only the thoracic wall.[2,3] In our previous experience, MRI follow-up was not impaired, and additional imaging exams can be performed, such as ultrasound or mammogram to obtain an adequate analysis of the parenchyma.[2] Additionally, the vast majority of tumor recurrences are detected by mammography or examination, as palpable masses.[6] Thus, understanding the loco-regional distribution of recurrence is important given the expected location of the artifact. A chest wall recurrence may involve skin, muscle, and fascia beneath the site of the original breast tumor, as well as thoracic lymph nodes. These are less frequent than skin or subcutaneous recurrences, and can be detected by noticeable symptoms, ultrasound, and even positron emission tomography and computed tomography, which has high sensitivity and specificity to detect locoregional recurrence, and is recommended in asymptomatic patients with rising tumor markers.[2] In conclusion, MRI has higher sensitivity than other imaging modalities for cancer detection. The question that remains is whether asymptomatic patients who follow routine surveillance recommendations glean true benefit from a limited chest wall area examination by means of MRI, considering its challenges. MRI is very costly and rarely covered by insurance, depending on the country; there are available concomitant imaging alternatives; and further, there remains a specificity debate. This quandary may better represent the true crossroad between the benefits and risks of the RFID-enabled technology.

DISCLOSURE

Dr. Munhoz serves as a consultant/board member for Establishment Labs, Holdings, Inc.
  6 in total

1.  Prevalence of rupture in poly implant Prothèse silicone breast implants, recalled from the European market in 2010.

Authors:  Maria C Maijers; Francisus B Niessen
Journal:  Plast Reconstr Surg       Date:  2012-06       Impact factor: 4.730

Review 2.  Surgical Management of Locoregional Recurrence in Breast Cancer.

Authors:  Ashish Goel; Varun Kumar Agarwal; Vikash Nayak; Rekha Yogsrivas; Abhishek Gulia
Journal:  Indian J Surg Oncol       Date:  2021-05-20

Review 3.  Breast imaging surveillance after curative treatment for primary non-metastasised breast cancer in non-high-risk women: a systematic review.

Authors:  Jeroen Swinnen; Machteld Keupers; Julie Soens; Matthias Lavens; Sandra Postema; Chantal Van Ongeval
Journal:  Insights Imaging       Date:  2018-11-08

4.  Clinical and MRI Evaluation of Silicone Gel Implants with RFID-M Traceability System: A Prospective Controlled Cohort Study Related to Safety and Image Quality in MRI Follow-Up.

Authors:  Alexandre Mendonça Munhoz; Luciano Chala; Giselle de Melo; Ary de Azevedo Marques Neto; Tatiana Tucunduva
Journal:  Aesthetic Plast Surg       Date:  2021-06-01       Impact factor: 2.326

5.  Usefulness of Radio Frequency Identification Device in Diagnosing Rotation of Motiva SmoothSilk Implants after Augmentation Mammoplasty.

Authors:  Alexandre Mendonça Munhoz; Luciano Chala; Giselle Guedes de Melo; Ary de Azevedo Marques Filho; Tatiana Tucunduva; Rolf Gemperli
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-11-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.