Literature DB >> 35680854

Inconsistent kinetic isotope effect in ammonia charge exchange reaction measured in a Coulomb crystal and in a selected-ion flow tube.

Shaun G Ard1, Albert A Viggiano2, Brendan C Sweeny3, Bryan Long4, Nicholas S Shuman1.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35680854      PMCID: PMC9184617          DOI: 10.1038/s41467-022-30566-3

Source DB:  PubMed          Journal:  Nat Commun        ISSN: 2041-1723            Impact factor:   17.694


× No keyword cloud information.
L. S. Petralia et al. Nature Communications 10.1038/s41467-019-13976-8 (2020) The recent paper by Petralia et al.[1] reports a strong inverse kinetic isotope effect (KIE) of 0.3 ± 0.05 between the reactions of Xe+ (2P3/2) with NH3 and ND3. The measurement was taken with the Xe+ sympathetically cooled by Ca+ atoms in a Coulomb crystal to ~30 K and the NH3/ND3 introduced ambiently at 290 K. The authors point out that the observed KIE was unusual and speculate on why it might occur. We have measured the temperature-dependent kinetics (175–600 K) of both reactions using a variable temperature selected-ion flow tube (SIFT), reporting a KIE near 1 for all temperatures. The current rate constants agree reasonably well with the Coulomb crystal measurements for both the NH3 and ND3 reactions given the absolute uncertainties. However, the differences are in opposite directions resulting in a large discrepancy in the KIE between the experiments. Measurements were performed using the previously described variable ion source and temperature-adjustable selected-ion flow tube (VISTA-SIFT)[2]. Ions were produced using an electron impact ion source yielding both ground Xe+(2P3/2) and excited state Xe+(2P1/2), then mass-selected and injected into a flow tube maintained at ~0.3 Torr of fast flowing helium gas. In order to ensure that the present results refer only to Xe+(2P3/2), we used the method of Smith and Adams[3,4] to selectively react Xe+(2P1/2) with N2O upstream in the flow tube prior to the addition of NH3/ND3. The rate constants were measured by monitoring the first order decay of Xe+(2P3/2) as a function of the concentration of NH3/ND3. Without N2O present, the Xe+ signal decayed via a double exponential indicating the reactive contribution of both states. With N2O added, single exponential decay was observed over three orders of magnitude, indicating >99.9% of ions were in the ground state. Temperature was varied by either resistively heating the entirety of the flow tube or by pulsing liquid nitrogen through copper tubing braised to the flow tube. Collisions between the reactant species and the helium buffer gas ensure rapid thermalization to the temperature of the flow tube wall. Errors in these measurements are +/−30% absolute and +/−20% relative, as is typical for this technique[5,6]. Reaction with contaminants or isotopic mixing of NH3 and ND3 are ruled out as time-of-flight mass spectra are taken for the entirety of the experiments and the only product ions observed are clearly identified and directly attributed to primary or secondary chemistry with the supplied reactants. The rate constants reported are directly determined from Xe+(2P3/2) signal decrease, but are consistent with those derived from unquenched data including Xe+(2P1/2), as well as from modeling the product ion increases observed, but only when properly accounting the continued chemistry of the product ions with NH3/ND3 (e.g., NH3+ + NH3 → NH4+ + NH2)[7]. Figure 1 shows the rate constants measured as a function of temperature for both reactions and Fig. 2 shows the KIE (kNH3/kND3) as a function of temperature. Both reactions occur at an appreciable fraction of the Su-Chesnavich parameterized collision rate[8] for ion-permanent dipole reactions. The Coulomb trap experiments were estimated to be at an effective translational temperature of ~260 K. For the ND3 rate constants, the agreement is reasonable, within the error of either measurement. The agreement for the NH3 reaction is marginal, only within mutual uncertainty of both measurements, and the difference is opposite that of ND3. The present results agree well with three previous room temperature values for the NH3 reaction including two performed at low pressure[3,4,9,10]. For the KIE, the agreement is not satisfactory, with the present measurements consistent with a value of 0.95 ± 0.15 at all temperatures with a possible small positive temperature dependence, while the Coulomb crystal value is 0.3 ± 0.05 at 260 K.
Fig. 1

Comparison of Xe+ + NH3/ND3 rate constants.

Experimental rate constants for Xe+ + NH3(red)/ND3(blue) as a function of temperature for the present work (solid circles/squares) with error bars indicating the 95% confidence region, as well as those previously published (open symbols): Derai et al. (up triangle, ref. [9]) and Chau and Bowers (up triangle, ref. [10]), Smith, Adams and co-workers (down triangle, ref. [3,4]), Petralia et al. (diamonds, ref. [1]). Solid curves are the parameterized capture rate constants from ref. [8].

Fig. 2

Comparison of kinetic isotope effects for Xe+ + NH3/ND3.

Experimentally determined kinetic isotope effect (k(Xe+ + NH3)/k(Xe+ + ND3)) as a function of temperature derived from the present work (circles) and of Petralia et al. (ref. [1]) squares. Error bars indicate the 95% confidence region.

Comparison of Xe+ + NH3/ND3 rate constants.

Experimental rate constants for Xe+ + NH3(red)/ND3(blue) as a function of temperature for the present work (solid circles/squares) with error bars indicating the 95% confidence region, as well as those previously published (open symbols): Derai et al. (up triangle, ref. [9]) and Chau and Bowers (up triangle, ref. [10]), Smith, Adams and co-workers (down triangle, ref. [3,4]), Petralia et al. (diamonds, ref. [1]). Solid curves are the parameterized capture rate constants from ref. [8].

Comparison of kinetic isotope effects for Xe+ + NH3/ND3.

Experimentally determined kinetic isotope effect (k(Xe+ + NH3)/k(Xe+ + ND3)) as a function of temperature derived from the present work (circles) and of Petralia et al. (ref. [1]) squares. Error bars indicate the 95% confidence region. It should be noted that the experiments take place under very different pressure regimes: ~0.3 Torr in the current work, as well as that by Smith, Adams, and co-workers[3,4], ~5 × 10−6 Torr in the ICR work of Derai et al. and of Chau and Bowers[9,10], and ~4 × 10−9 Torr in the work of Petralia et al.[1]. A pressure effect would require the lifetime of a (Xe-NH3/ND3)*+ complex to be long enough such that a collision with the helium buffer occurs (~200 ns under the SIFT conditions). The complex lifetimes were calculated using statistical theory (implemented using the simplified statistical adiabatic channel model[11] using molecular frequencies calculated at the MP2/def2-TZVP level) to be much shorter, between 50 and 500 ps across the relevant temperature range assuming the extremes of statistical theory, i.e., phase space theory (PST) or Rice–Ramsperger–Kassel–Marcus (RRKM) theory. In either limit, it is unlikely for the complex to encounter even a single collision with helium. The pressure dependence for the NH3 reaction was measured using the SIFT over the modest accessible range of 0.2–0.6 Torr and no dependence in the rate constant was found. While we cannot definitively rule out pressure as a cause of the discrepancy, it appears unlikely.
  3 in total

1.  Old School Techniques with Modern Capabilities: Kinetics Determination of Dynamical Information Such as Barriers, Multiple Entrance Channel Complexes, Product States, Spin Crossings, and Size Effects in Metallic Ion-Molecule Reactions.

Authors:  Shaun G Ard; Albert A Viggiano; Nicholas S Shuman
Journal:  J Phys Chem A       Date:  2021-04-22       Impact factor: 2.781

2.  Reaction of Mass-Selected, Thermalized V nO m+ Clusters with CCl4.

Authors:  Brendan C Sweeny; Shaun G Ard; Albert A Viggiano; Nicholas S Shuman
Journal:  J Phys Chem A       Date:  2019-05-30       Impact factor: 2.781

3.  Strong inverse kinetic isotope effect observed in ammonia charge exchange reactions.

Authors:  L S Petralia; A Tsikritea; J Loreau; T P Softley; B R Heazlewood
Journal:  Nat Commun       Date:  2020-01-10       Impact factor: 14.919

  3 in total
  1 in total

1.  Reply to: Inconsistent kinetic isotope effect in ammonia charge exchange reaction measured in a Coulomb crystal and in a selected-ion flow tube.

Authors:  L S Petralia; A Tsikritea; J Loreau; T P Softley; B R Heazlewood
Journal:  Nat Commun       Date:  2022-06-09       Impact factor: 17.694

  1 in total