Se Woo Park1, Sang Soo Lee2, Jae Hee Cho3, Eui Joo Kim4, Chan Hyuk Park5, Da Hae Park6, Kyong Joo Lee6. 1. Division of Gastroenterology, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, 7, Keunjaebong-gil, Hwaseong-si, Gyeonggi-do, 18450, South Korea. mdsewoopark@gmail.com. 2. Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil Songpa-gu, Seoul, 05505, South Korea. euslove68@gmail.com. 3. Division of Gastroenterology, Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, South Korea. 4. Department of Internal Medicine, Gil Medical Center, Gachon University College of Medicine, Incheon, South Korea. 5. Department of Internal Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, South Korea. 6. Division of Gastroenterology, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, 7, Keunjaebong-gil, Hwaseong-si, Gyeonggi-do, 18450, South Korea.
Abstract
BACKGROUND AND AIMS: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) may be a feasible and useful alternative in patients with malignant biliary obstruction (MBO) after failed endoscopic retrograde cholangiopancreatography (ERCP). To date, the risk factors for adverse events (AEs) and long-term outcomes of EUS-HGS have not been fully explored according to stent type. Therefore, we evaluated potential risk factors for AEs and long-term outcomes of EUS-HGS. METHODS: In total, 120 patients who underwent EUS-HGS were retrospectively reviewed. A multivariate analysis through Cox proportional hazard and logistic regression model was used to identify the risk factors for stent dysfunction and AEs, respectively. Stent patency and patient survival were evaluated using Kaplan-Meier plots with a log-rank test for each stent. RESULTS: The technical and clinical success rates were 96.2% (102/106) and 83.0% (88/106). The median duration of stent patency was longer in self-expandable metal stents (SEMS) compared to plastic stents (PS) (158 vs. 108 days). Kaplan-Meier analysis indicated that the type of stent was not associated with stent patency (Hazard ratios [HR] 0.997, 95% confidence interval [CI] [0.525-1.896]) or overall survival. In addition, multivariate analysis indicated that hilar MBO significantly associated with stent dysfunction (HR, 2.340; 95% CI, 1.028-5.326, p = 0.043) and late AEs. CONCLUSIONS: Given the lower incidence of AEs and better long-term outcomes of EUS-HGS, it can be considered a safe alternative to ERCP or percutaneous approaches regardless of which stent is used. Furthermore, hilar MBO was established as a potential risk factor for stent dysfunction and late AEs.
BACKGROUND AND AIMS: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) may be a feasible and useful alternative in patients with malignant biliary obstruction (MBO) after failed endoscopic retrograde cholangiopancreatography (ERCP). To date, the risk factors for adverse events (AEs) and long-term outcomes of EUS-HGS have not been fully explored according to stent type. Therefore, we evaluated potential risk factors for AEs and long-term outcomes of EUS-HGS. METHODS: In total, 120 patients who underwent EUS-HGS were retrospectively reviewed. A multivariate analysis through Cox proportional hazard and logistic regression model was used to identify the risk factors for stent dysfunction and AEs, respectively. Stent patency and patient survival were evaluated using Kaplan-Meier plots with a log-rank test for each stent. RESULTS: The technical and clinical success rates were 96.2% (102/106) and 83.0% (88/106). The median duration of stent patency was longer in self-expandable metal stents (SEMS) compared to plastic stents (PS) (158 vs. 108 days). Kaplan-Meier analysis indicated that the type of stent was not associated with stent patency (Hazard ratios [HR] 0.997, 95% confidence interval [CI] [0.525-1.896]) or overall survival. In addition, multivariate analysis indicated that hilar MBO significantly associated with stent dysfunction (HR, 2.340; 95% CI, 1.028-5.326, p = 0.043) and late AEs. CONCLUSIONS: Given the lower incidence of AEs and better long-term outcomes of EUS-HGS, it can be considered a safe alternative to ERCP or percutaneous approaches regardless of which stent is used. Furthermore, hilar MBO was established as a potential risk factor for stent dysfunction and late AEs.