Literature DB >> 35678910

Correlation between Surface Area Ratio of Medial to Lateral Tibial Plateau and Knee Alignment in Adults.

Song Gong1, Li-Zhi Han1, Tian-Lun Gong1, Yi-Hu Yi1, Ruo-Yu Wang2, Wei-Hua Xu3.   

Abstract

OBJECTIVE: This study aimed to investigate the correlation between the surface area ratio of medial tibial plateau (MTP) to lateral tibial plateau (LTP) and the mechanical tibiofemoral angle (mTFA).
METHODS: Lower limb computed tomography (CT) images were collected at our hospital. Then, the original CT data were analyzed and reconstructed using medical image processing software. The proximal and distal centres of the femur and tibia were marked. The surface areas of MTP and LTP were identified using image processing software. GraphPad Prism 8.0.2 was used to perform the statistical analysis.
RESULTS: The surface area ratio of MTP to LTP was significantly correlated with the mTFA in all patients (P<0.0001), male group (P<0.0001), female group (P<0.0001), varus group (P<0.0001), and valgus group (P=0.002). Furthermore, the surface area of MTP and LTP was significantly greater in the male group than in the female group (P<0.0001). There was significant difference in the surface area of the MTP between the varus and valgus groups (P<0.0001). Significant difference was also observed in the surface area ratio of MTP to LTP between the varus and valgus groups (P<0.0001).
CONCLUSION: The surface area ratio of MTP to LTP was correlated with the mTFA. Within a certain range, the smaller the mTFA, the greater the surface area ratio of MTP to LTP. For patients undergoing total knee arthroplasty, of whom the surface area of the MTP was basically equal to that of the LTP, it is recommended that the osteotomy should be performed in accordance with mechanical alignment standards, and that a symmetrical tibial plateau prosthesis should be used. For patients whose surface area of MTP is significantly greater than that of the LTP, it is recommended that the osteotomy should be performed in accordance with kinematic alignment standards, and that an anatomical tibial plateau prosthesis should be used.
© 2022. Huazhong University of Science and Technology.

Entities:  

Keywords:  knee alignment; lateral tibial plateau; medial tibial plateau; prosthesis types; surface area ratio; total knee arthroplasty

Mesh:

Year:  2022        PMID: 35678910     DOI: 10.1007/s11596-022-2590-8

Source DB:  PubMed          Journal:  Curr Med Sci        ISSN: 2523-899X


  1 in total

1.  Applications of patient-specific 3D printing in medicine.

Authors:  Martin Heller; Heide-Katharina Bauer; Elisabeth Goetze; Matthias Gielisch; Klaus E Roth; Philipp Drees; Gerrit S Maier; Bernhard Dorweiler; Ahmed Ghazy; Meik Neufurth; Werner E G Müller; Heinz C Schröder; Xiaohong Wang; Christian-Friedrich Vahl; Bilal Al-Nawas
Journal:  Int J Comput Dent       Date:  2016       Impact factor: 1.883

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.