Literature DB >> 356760

Estimation of IgM rheumatoid factors by fluorimetry.

D J Lea, D J Ward.   

Abstract

Sheep red cells coated with rabbit IgG antibody may be used to detect IgM rheumatoid factors either by agglutination or microscopically by the fluorescence of antihuman IgM antibody conjugate bound to rheumatoid factors on the cell surface. By substituting for red cells the plastic surface of a filter disc coated with rabbit IgG it was possible to elute the bound conjugate and measure the fluorescence in a fluorimeter. The results of both the sheep cell agglutination test and the fluorescence test agreed quite well for the majority of sera; both tests seemed to reflect IgM rheumatoid factor concentrations in these sera. The difficulties encountered in attempting to define and measure accurately rheumatoid factor concentrations in a serum are emphasised.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 356760      PMCID: PMC1000215          DOI: 10.1136/ard.37.3.247

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  17 in total

1.  A modified assay for the Waaler-Rose test using latex particles coated with rabbit gamma-globulins.

Authors:  R Marcolongo; M Saletti
Journal:  Pathol Microbiol (Basel)       Date:  1974

2.  Distribution of antibody-binding affinity. 3. Detection of low affinity antibody in the presence of high affinity antibody.

Authors:  Y K Kim; T P Werblin; G W Siskind
Journal:  J Immunol       Date:  1974-06       Impact factor: 5.422

3.  Immunochemical quantitation of IgG: influences of the antiserum and of the antigenic population.

Authors:  A Grubb
Journal:  Scand J Clin Lab Invest       Date:  1973-06       Impact factor: 1.713

4.  Enzyme-linked immunosorbent assay, Elisa. 3. Quantitation of specific antibodies by enzyme-labeled anti-immunoglobulin in antigen-coated tubes.

Authors:  E Engvall; P Perlmann
Journal:  J Immunol       Date:  1972-07       Impact factor: 5.422

5.  Evaluation of the immunological specificity of fluorescein-labelled anti-human IgM conjugates.

Authors:  S Chantler; M Haire
Journal:  Immunology       Date:  1972-07       Impact factor: 7.397

6.  The serologic diagnosis of rheumatoid arthritis. The latex-rabbit gamma-globulin fixation test.

Authors:  H G Grieble; G L Bach; M Szanto; T O Anderson
Journal:  J Chronic Dis       Date:  1969-02

7.  "Sandwich" solid phase radioimmunoassay for the quantitative deterimination of human immunoglobulins.

Authors:  S E Salmon; G Mackey; H H Fudenberg
Journal:  J Immunol       Date:  1969-07       Impact factor: 5.422

8.  The validity of the radial immunodiffusion method for the quantitative determination of human IgM. Evaluation of a modified method.

Authors:  A M de Bruyn; F Klein
Journal:  J Immunol Methods       Date:  1976       Impact factor: 2.303

9.  Laboratory diagnosis of rheumatoid arthritis: a solid phase radioassay for IgG and IgM antiglobulins.

Authors:  L J Nineham; F C Hay; I M Roitt
Journal:  J Clin Pathol       Date:  1976-12       Impact factor: 3.411

10.  Iodinated versus fluorescent labelling in the radioallergosorbent test (RAST) for the determination of serum IgE levels.

Authors:  P Cukor; M E Woehler; C Persiani; A Fermin
Journal:  J Immunol Methods       Date:  1976       Impact factor: 2.303

View more
  2 in total

1.  Anti-collagen antibodies in sera from rheumatoid arthritis patients.

Authors:  H K Beard; R Ryvar; J Skingle; C L Greenbury
Journal:  J Clin Pathol       Date:  1980-11       Impact factor: 3.411

2.  Binding of isolated rheumatoid factors to histone proteins and basic polycations.

Authors:  R N Hobbs; D J Lea; K K Phua; P M Johnson
Journal:  Ann Rheum Dis       Date:  1983-08       Impact factor: 19.103

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.