| Literature DB >> 35673590 |
Abheek Ghosh1, Jian Zhang1, Nabeel Mohsin Akhter1.
Abstract
OBJECTIVE: Transradial access has become more popular in body intervention procedures but has not been ubiquitously adapted. This study assesses the efficacy of this approach in Yttrium-90 labeled microspheres radioembolization. To compare transradial to transfemoral access in hepatocellular carcinoma patients who underwent Yttrium-90 radioembolization.Entities:
Keywords: Hepatocellular carcinoma; Radioembolization; Yttrium-90 microspheres
Year: 2022 PMID: 35673590 PMCID: PMC9168346 DOI: 10.25259/JCIS_213_2021
Source DB: PubMed Journal: J Clin Imaging Sci ISSN: 2156-5597
TRA was accessed with a 21-gauge needle and then a 0.018-in wire was inserted. After needle removal, a 5 French Glidesheath Slender (Terumo, Somerset, NJ) vascular introducer sheath was placed over a 0.021-inch SS microwire (Terumo, Somerset, NJ) without skin incision at the puncture site. All patients with a type D response on the Barbeau’s test were excluded from the study. TFA was accessed with a 21gauge needle and then this needle was exchanged for a 5 French transitional micropuncture sheath over an 0.018-in nitinol wire. The micropuncture sheath was then exchanged for a 5 French × 10 cm vascular sheath over a 0.035-in × 145 cm Coons wire. Both accesses were obtained via ultrasound.
| Average age and demographics of TRA and TFA cohorts. | |||
|---|---|---|---|
| Age | TRA | TFA | |
| <65 Y | 112 | 37 | 0.93 |
| ≥65 Y | 76 | 26 | 0.12 |
| Total #s | 188 | 63 | |
|
| |||
|
|
|
| |
| Male | 143 | 45 | |
| Female | 45 | 18 | |
| Total #s: | 188 | 63 | |
Average procedural costs in Y90 radioembolization: TRA versus TFA.
| All ( | TRA ( | TFA ( | ||
|---|---|---|---|---|
| In suite procedure time (min) | 124.8 | 111.7 | 165.6 | <0.01 |
| Material cost (USD) | 1822.8 | 1632.3 | 2013.1 | <0.01 |
Average radiation exposure in Y90 radioembolization: TRA versus TFA.
| All ( | TRA ( | TFA ( | ||
|---|---|---|---|---|
| Peak skin dose (mGy) | 909.1 | 880.2 | 995.1 | 0.25 |
| Fluoroscopy time (min) | 17.1 | 16.1 | 19.7 | 0.06 |
Average administered contrast volume in Y90 radioembolization: TRA versus TFA.
| All ( | TRA ( | TFA ( | ||
|---|---|---|---|---|
| Contrast (ml) | 70.7 | 69.2 | 75.2 | 0.03 |