Literature DB >> 35669352

Methodological Study on the Establishment of HLA/HPA Gene Bank of Platelet Donors and Its Clinical Application.

Deyi Xu1, Chunxia Sun2, Lu Yu1, Yunlei He1, Gang Deng1, Jiwei Zhang1.   

Abstract

The current study aimed at establishing a large-scale platelet donor database with known HPA and HLA genotypes in Ningbo, to provide matched platelets for the clinic and prevent the occurrence of ineffective immune platelet transfusion refractoriness (PTR). The platelet banks of clinical donor wtih HLA-A, HLA-B, HPA1, HPA2, HPA3, HPA4, HPA5, HPA6, HPA10, HPA15 and HPA21 genotyps were established. Meanwile, the platelet gene matching was performed on the donor. It was found that there were phenotype polymorphisms in 1000 donnors with HPA1, HPA2, HPA3, HPA4, HPA5, HPA6, HPA10, HPA15 and HPA21 genotyps, and allel polymorphism distribution in donnors with HPA1, HPA2, HPA3, HPA4, HPA5, HPA6, HPA15, HPA21 genotyps. The frequency of HPA10 was a gene, and not b gene, showing a single linear distribution. The HPA 2, HPA3, HPA15 system were the most polymorphic with three phenotypes: aa, ab, bb. In the HLA-A allele, the highest frequency is A*11:01 (24.25%). There were 13 alleles that were greater than 1%, such as A*24:02, A*02:01, A*33:03, and the accumulated frequency reached 96.20%. In the HLA-B allele, the highest gene frequency was B*40:01 (13.40%). There were 24 alleles that were greater than 1%, such as B*46: 01, B*58: 01, B*15: 01, and the accumulated frequency reached 91.60%. Platelet antibody cross matching was performed on 100 blood samples from patients with thrombocytopenia after multiple platelet transfusions. The number of consistent samples was 46 (46%). Twenty patients were transfused with platelet cross matching. Among them, 18 patients had obvious improvement in clinical symptoms and good hemostatic effect after transfusion, which was judged to be effective. Platelet donor HPA and HLA-A, B antigen genotyping database provided patients with individual appropriate platelets, and provided the effectiveness of immune platelet infusion ensuring effective platelet transfusion.
© The Author(s), under exclusive licence to Indian Society of Hematology and Blood Transfusion 2022.

Entities:  

Keywords:  HLA; HPA; Platelet donor database

Year:  2022        PMID: 35669352      PMCID: PMC9135102          DOI: 10.1007/s12288-022-01547-9

Source DB:  PubMed          Journal:  Indian J Hematol Blood Transfus        ISSN: 0971-4502            Impact factor:   0.915


Introduction

Platelet transfusion refractoriness (PTR) is one of the difficult problems in clinical blood transfusion. The ineffective platelet infusion caused by immune platelet antibodies (mainly HLA and/or HPA) accounted for about 18–25% [1]. HLA antigen, also known as tissue antigen, is widely found on the surface of nuclear cells with strong immunogenicity and easily causing alloimmune response. Patients with long-term repeated blood transfusion are prone to produce HLA antibodies and the antibody positive rate increases with the increase of blood transfusion times. HLA antibody is the main cause of ineffective platelet transfusion caused by immune reasons. At present, there are two main ways to solve PTR: one way is to screen HLA/HPA specific platelets through serological platelet cross matching test. The second way is to establish a donor platelet bank with known HLA and HPA genotypes, and select blood donors with the HLA/HPA gene for platelet transfusion. Therefore, the establishment of HLA-A, HLA-B and HPA gene database of unpaid blood donors to provide gene matched donors platelet for patients is a feasible method to solve the ineffective platelet transfusion, improving the clinical efficacy and further improve the safety of blood transfusion.

Materials and Methods

Study Object

The platelet donor database was established by selecting 1000 blood donors who participated in the platelet donation for more than 3 times from January 2018 to December 2021 for HLA-A, HLA-B, HPA-1, HPA-2, HPA-3, HPA-4, HPA-5, HPA-6, HPA-10, HPA-15, and HPA-21 genotyping, including 550 cases men and 450 cases women, A (324 cases), B (237 cases), O (93 cases) and AB (346 cases), respectively, aged 18–55. All of them signed the informed consent form of platelet blood group genotyping of component blood donors, which voluntarily joined the platelet blood group genotyping database and was collected whole blood samples. 5 ml venous whole blood was collected, anticoagulated with EDTA and stored in 4 °C for 15 days or − 20 °C for 1 year.

Reagent and Instrument

DNA extraction kit (Tianlong Biotechnology Co., Ltd.), HLA-A, B genotyping detection kit (PCR-SBT method, Jiangsu Weihe Biotechnology Co., Ltd.), Human platelet-specific antigen HPA-1-6, 10,15,21 genotyping detection kit (quadruple fluorescent PCR method, Jiangsu Weihe Biotechnology Co., Ltd.), Taq DNA polyase and high fidelity enzymes (Promega Corporation), Big Dye Terminator (v3.1), ExoSAP-IT; Platelet antibody detection kit (Capture method, IMMUCOR Corporation), ABI 7500 fluorescent PCR instrument, ABI 3730 Sequencer, Frozen centrifuge (Sigma, Germany).

Method

Nucleic Acid Extraction

The ZTLYQ nucleic acid extraction kit and Tianlong NP968-S automatic nucleic acid extractor was performed, and the magnetic beads were adsorbed, transferred and released through a special magnetic rod based on the principle of magnetic bead adsorption, so as to realize the transfer of magnetic beads and nucleic acid and automatically complete the extraction of sample nucleic acid. The DNA concentration of the obtained sample should be between 15 and 40 ng/μL, the A260/A280 absorbance should be between 1.6 and 2.0, which can be tested immediately, stored at 4 °C for 10 days or − 20 °C for 6 months.

HLA-A, B Genotyping

The specific primers were designed according to the known human leukocyte antigen gene sequence and the specific primers for amplification reaction were selected according to the characteristic table of amplification primers. The amplification PCR reaction procedure was set as follows: 95 °C for 5 min, 93 °C for 30 s, 63 °C for 40 s, 72 °C for 2 min and 30 s, 36 cycles in total; 72 °C for 5 min; 4 °C until removed. Electrophores: prepare 2.0% agarose gel with grade DNA agarose and 0.5 × TBE buffer, running gel at 8–10 V/cm, 200 V, for about 10–20 min. Purification of PCR product: for the reaction wells that want to be sequenced, add 4 μL ExoSAP-IT to remove excess primers and DNA. Sequencing reaction: the sequencing reaction was carried out. The reaction system includes: 1.5 μl BDT sequencing reagent, 2.5 μl primers for sequencing, 1 μl purified PCR product. Sequencing PCR reaction program setting: 96 °C for 1 min, 98 °C for 25 s, 60 °C for 2 min 30 s, 25 cycles in total, 4 °C until removed. Purification of sequencing products: excess BDT was removed by ethanol precipitation. Preparation before sequencing: before sequencing, 15 μl HiDi formamide (HiDi formamide) was redissolved and treated with PCR at 95 °C for 2 min. Reading of sequencing results: HLA-A, B genotypes were analyzed by supporting intelligent analysis software.

HPA-1–6, 10, 15 and 21 Genotyping

The HPA-1, HPA-2, HPA-3, HPA-4, HPA-5, HPA-6, HPA-10, HPA-15 and HPA-21 genes were qualitatively genotyped by real-time fluorescent PCR and TaqMan probe technology. According to the HPA gene sequences published in the database [2], the allele-specific primers and probes were designed by the amplification refractory mutation system (ARMS). With FAM/VIC/ROX labeling, 18 alleles are distributed in 6 reaction tubes. ABI 7500 fluorescence quantitative PCR instrument was performed, and the PCR amplification cycle parameters are: 95 °C for 2 min 30 s, 1 cycle; 94 °C for 15 s, 65 °C for 55 s, 35 cycles, and set according to the operation of the instrument. The detection channels included FAM, VIC, ROX, CY5 and Cy5 was the internal standard gene reporting fluorescence. At the end of the reaction, the reference values of fluorescence threshold were adjusted to FAM 5000, VIC 5000, ROX 10,000, CY5 5000, and the baseline reference value 3–15. According to the test results, the HPA 1–6, 10, 15, 21 genotypes of the samples to be tested are directly analyzed by 7500 Software v2.0.6 intelligent software analysis.

The HPA Allele Frequency

The HPA allele frequency was calculated by direct counting method, The calculation formula of the HPA antigen mismatch rate was as follows: The a antigen mismatch rate = b2(1 − b2), The b antigen mismatch rate = a2(1 − a2); The HPA antigen random infusion mismatch rate Pab = 2ab (1 − ab).

Platelet Cross-Matching

Platelet cross-matching was performed by IMMUCOR platelet antibody detection kit (capture method). 50 μl donor platelet suspension was added to the microplate, centrifuged by 45–65 g for 5 min (platelets were fixed at the bottom of the microplate),.the liquid in the micropore was gently poured out, and washed with 0.9% NaCl for 6 times, and added 2 drops of low ionic strength solution (LISS), and added 50μL recipient serum or plasma, and added positive control and negative control into the control hole. The mixture was incubated at 37 °C for 45 min, washed the reaction plate with 0.9% NaCl for 6–8 times, and added 50 μL indicator red blood cells, and centrifuged at 700–900 g for 1 min. The experimental results were determined and observed.

Platelet Donor Selection

The donors were selected in the platelet donor database according to the cross reaction groups (CREGs) matching technology, and the matching classification was in accordance with the American AABB platelet HLA matching classification standard.

Statistical Analysis

Data were presented as mean ± SD. Corrected count increment, CCI ≥ 4.5 × 109/L indicated that the transfusion was effective and CCI < 4.5 × 109/L indicated that the transfusion was invalid. CCI = ΔPLC × BSA/platelets transfused. Statistical analyses were performed with SPSS 17.0. Statistical significance between groups was evaluated by Mann–Whitney U test. P value < 0.05 was considered statistically significant.

Result

Genotyping of HPA

The HPA-1, HPA-2, HPA-3, HPA-4, HPA-4, HPA-5, HPA-6, HPA-10, HPA-15 and HPA-21 genes were qualitatively genotyped by real-time fluorescent PCR method combined with TaqMan probe technology. Table 1 showed the genotypes and gene frequencies of the HPA genes in platelet donor. The HPA real-time fluorescent PCR diagram was shown in Fig. 1.
Table 1

Genotypes and gene frequencies of HPA-1–6, 10, 15, 21 in platelet donor

Genotypeaaaa (%)abab (%)bbbb (%)a (%)b (%)Mismatch rate (%)
HPA-198798.70131.3000.000.99350.00651.28
HPA-288388.3011411.4030.300.94000.060010.64
HPA-331831.8048448.4019819.800.56000.440037.14
HPA-499999.9010.1000.000.99950.00050.10
HPA-596996.90313.1000.000.98450.01553.01
HPA-697497.40262.6000.000.98700.01302.53
HPA-101000100.0000.0000.001.00000.00000
HPA-1530130.1048348.3021621.600.54250.457537.32
HPA-2197597.50252.5000.000.98750.01252.44

HPA mismatch rate Pab = 2ab (1 − ab)

Fig. 1

A and B show some HPA real-time fluorescent PCR diagram

Genotypes and gene frequencies of HPA-1–6, 10, 15, 21 in platelet donor HPA mismatch rate Pab = 2ab (1 − ab) A and B show some HPA real-time fluorescent PCR diagram In the 1000 samples, there were polymorphisms in the HPA-1, HPA-2, HPA-3, HPA-4, HPA-5, HPA-6, HPA-10, HPA-15 and HPA-21 systems. The genotype aa frequency of HPA-1 system was 0.9870, the ab frequency was 0.0130; the genotype aa frequency of HPA-2 system was 0.8830, the ab frequency was 0.1140, the bb frequency was 0.0030; the genotype aa frequency of HPA-3 system is 0.3180, the ab frequency was 0.4840, the bb frequency was 0.1980; the genotype aa frequency of HPA-4 system was 0.9990, the ab frequency is 0.0010; the genotype aa frequency of HPA-5 system was 0.9690, the ab frequency was 0.0310; the genotype aa frequency of HPA-6 system was 0.9740, the ab frequency was 0.0260; the HPA-10 system a frequency was 1.0000, the b frequency was 0.0000; the genotype aa frequency of HPA-15 system was 0.3010, the ab frequency was 0.4830, the bb frequency was 0.2160; the HPA-21 system aa frequency was 0.9750, the ab frequency was 0.0250. The frequencies of the HPA-1, HPA-2, HPA-3, HPA-4, HPA-5, HPA-6, HPA-10, HPA-15 and HPA-21 allele for platelet donors were shown in Table 1. All the alleles we detected revealing the polymorphic distribution apart from HPA 10. The frequency of HPA10 a gene was 1 and no b gene was found, showed a single linear distribution. The HPA-2, HPA-3 and HPA-15 systems had the most nucleotide polymorphim with three phenotypes: aa, ab, bb.

The HLA-A, B Genes and Frequencies

Detection of HLA-A and HLA-B Alleles

The direct sequencing method was adopted for gene detection, and the reading results of HLA-A and B genotypes were analyzed by using the intelligent analysis software matched with the instrument. The frequencies of HLA-A and HLA-B allele in platelet donors were shown in Tables 2 and 3, respectively. The genotyping and sequencing diagram was shown in Figs. 2 and 3.
Table 2

HLA-A allele frequencies in platelet donors

HLA-AnFrequency (%)HLA-AnFrequency (%)
A*11:0148524.25A*24:0740.20
A*24:0232016.00A*69:0140.20
A*02:0123711.85A*30:0230.15
A*33:031979.85A*23:0120.10
A*02:071939.65A*33:0120.10
A*30:01964.80A*74:0120.10
A*02:06854.25A*02:0210.05
A*31:01673.35A*11:0310.05
A*02:03603.00A*02:2810.05
A*11:02572.85A*02:5310.05
A*26:01472.35A*03:0210.05
A*01:01311.55A*24:0310.05
A*03:01281.40A*24:0810.05
A*29:01211.05A*24:1010.05
A*32:01150.75A*26:0310.05
A*68:01120.60A*30:0410.05
A*24:2070.35A*30:1810.05
A*02:0560.30A*31:3210.05
A*02:1060.30A*74:0310.05
Table 3

Allele frequencies of HLA-B in platelet donors

HLA-BnFrequency (%)HLA-BnFrequency (%)HLA-BNFrequency (%)
B*40:0126813.40B*15:18231.15B*18:0220.10
B*46:0124012.00B*15:27221.10B*35:0820.10
B*58:011768.80B *27:05190.95B*38:0120.10
B*15:011226.10B*07:05150.75B*39:0520.10
B*13:021095.45B*67:01150.75B*40:4020.10
B*50:011035.15B*35:03110.55B*49:0120.10
B*13:01793.95B*08:0190.45B*51:0120.10
B*15:02743.70B*37:0190.45B*15:1010.05
B*55:02613.05B*56:0190.45B*15:1510.05
B*54:01582.90B*35:0560.30B*15:1710.05
B*38:02532.65B*40:0360.30B*15:2510.05
B*35:01512.55B*44:0260.30B*15:3510.05
B*39:01512.55B*48:0360.30B*15:3810.05
B*40:06502.50B*15:0750.25B*18:0110.05
B*40:02482.40B*35:0230.15B*27:0610.05
B*27:04391.95B*53:0130.15B*39:1510.05
B*52:01361.80B*55:0430.15B*39:2410.05
B*15:11311.55B*59:0130.15B*41:0110.05
B*48:01311.55B*14:0220.10B*45:0110.05
B*57:01311.55B*15:0520.10B*55:0110.05
B*07:02291.45B*15:1220.10B*55:0710.05
B*44:03241.20B*15:2920.10B*81:0110.05
B*51:02241.20B*15:3220.10
Fig. 2

C and D show the genotyping and sequencing map of A*11:01 and A*24:02

Fig. 3

E and F show the genotyping and sequencing map of B*40:01 and B*46:01

HLA-A allele frequencies in platelet donors Allele frequencies of HLA-B in platelet donors C and D show the genotyping and sequencing map of A*11:01 and A*24:02 E and F show the genotyping and sequencing map of B*40:01 and B*46:01

Frequencies of HLA-A, HLA-B Antigens in Platelet Donors

The frequencies of HLA-A, HLA-B antigens of platelet donors were shown in Table 4. The highest frequency of HLA-A antigen was A11 (26.7%), and HLA-A antigens with gene frequency were greater than 1% included A2, A24, A33, A30, A31, A203, A26, A1, A3 and A29, with a cumulative frequency of 97.75%. Meanwhile, the highest frequency of HLA-B antigen was B60 (12.7%), and 19 kinds of HLA-B antigens with gene frequency were greater than 1%, with a cumulative frequency of 95.20%, including B46, B13, B58, B62, B61, B75, B51, B35, B55, B27, B54, B38, B3901, B7, B48, B52, B44, B71 and B5102.
Table 4

Frequencies of HLA-A and B antigens in platelet donors

AntigennFrequency (%)AntigennFrequency (%)
HLA-AHLA-B
A1153426.7B6025412.70
A252226.1B4623611.80
A2433416.7B131949.70
A331989.9B581909.50
A301025.1B621618.05
A31723.6B611095.45
A203643.2B751055.25
A26482.4B51984.90
A1311.55B35733.65
A3291.45B55653.25
A29211.05B27592.95
A32160.8B54592.95
A68120.6B38562.80
A21060.3B3901512.55
A6940.2B7442.20
A7430.15B48371.85
A2320.1B52361.80
A240320.1B44301.50
B71241.20
B5102231.15
B57180.90
B67150.75
B50100.50
B890.45
B3790.45
B5690.45
B3930.15
B5930.15
B5330.15
B1830.15
B8130.15
B4920.10
B1520.10
B7620.10
B6520.10
B4510.05
B4110.05
B6310.05
Total20001002000100
Frequencies of HLA-A and B antigens in platelet donors

Platelet Cross-Match

Platelet antibody cross matching was performed on 100 blood samples from patients with thrombocytopenia after multiple transfusions. The number of compatible samples was 46 (46%). The number of platelets before and after platelet transfusion was counted among 100 patients. The number of platelets before platelet transfusion was (8.13 ± 3.52) × 109/L, and the number of platelets after transfusion was (35.28 ± 12.52) × 109/L, and the average platelet count increased by 27.15 × 109/L, and CCI value was 20.16, P < 0.005, which were significant differences between pre-transfusion and post-transfusion.

Clinical Application of HLA/HPA Gene Database

HLA database was used to search for platelet donors matched with gene "digital" data, and platelets were collected and infused. Twenty clinical patients were required HLA/HPA genotyping. In twenty cases of HLA genotyping patients, one case from Grade A donors of HLA genotyping, the number of pre-transfusion platelet was 7.15 × 109/L, and the number of platelet at 24 h post-transfusion was 38.26 × 109/L. Platelet count increased by 31.11 × 109/L and CCI value was 59.73 × 109/L, P value < 0.05. In addition, Grade B1U four cases, grade BU four cases, grade B1X five cases, BUX grade three cases, grade B2UX one case had been screened, there were a significant improvement in the mean CCI. However, in two patients (one grade B1U and one grade B2UX), there was no noticeable increase in CCI values, as the values were 3.72 × 109/L and 2.13 × 109/L, respectively. Comparison of 24 h CCI in HLA genotyping patients was shown in Table 5.
Table 5

Comparison of 24-h CCI in HLA genotyping patients ( ± s, × 109/L)

GroupnPre-transfusionPost-transfusion24 h CCIP value
Grade A17. 1 5 38.2659.73 < 0.05
Grade B1U49.13 ± 3.4536.18 ± 10.5251.93 ± 6.99 < 0.05
Grade BU48.79 ± 3.1232.28 ± 9.4845.10 ± 6.30 < 0.05
Grade B1X57.95 ± 3.0424.27 ± 8.6331.33 ± 584 < 0.05
Grade BUX37.85 ± 2.9823.19 ± 8.6729.45 ± 5.83 < 0.05
Grade B2UX17.6920.2224.06 < 0.05
Grade B1U19. 1111.053.72 > 0.05
Grade B2UX17.15 8.262.13 > 0.05
Comparison of 24-h CCI in HLA genotyping patients ( ± s, × 109/L)

Discussion and Conclusion

Platelet transfusion is a supportive therapy for blood diseases, tumors and other diseases. In China, platelet transfusion strategy is usually only based on ABO isotype, and patients are transfused with random platelets multiple times, generating various of alloimmune antibodies in blood. The genaration of alloimmune antibodies caused by the HPA and/or HLA is one of the reasons for the ineffective blood transfusion. It is a feasible method to detect the HPA and/or HLA genes, antigens and antibodies preventing PTR in clinic [3]. In the HPA system, we found that the HPA-2, HPA-3 and HPA-15 systems had the most nucleotide polymorphim and HPA-2b, HPA-3b and HPA-15b antigens had the highest proportion and mismatch rate, which were of important immunological significance in blood transfusion. In addition,the proportion of HPA-3b and HPA-15b antigen frequency was close to that reported by Tomoya H et al. (HPA-3b, 41.3%; HPA-15b, 48.8%) [4]. At present, the main HLA genotyping methods include PCR-SSP, PCR-SSO, PCR-SBT, flow cytometry, gene chip and so on. Among them, direct sequencing typing is the most accurate, complete and reliable genotyping method. In this study, we had established a platelet HLA gene database of 1000 donors by using direct sequencing technology. It can be seen from Table 2 that the highest frequency of HLA-A alleles was A*11:01, accounting for 24.25%. Alleles greater than 1% included A*24:02, A*02:01, A*33:03, A*02:07, A*30:01, A*02:06, A*31:01, A*02:03, A*11:02, A*26:01, A*01:01, A*03:01 and A*29:01, with a cumulative frequency of 96.20%. The common HLA allele HLA-A*24:02 accounts for 16.0%, which was close to South Korea (19.5%), Chinese in Hong Kong (14.7%) and Syria (12.9%), Other countries such as Japan (37.9%) and the Philippines (31.3%) are higher than our data, while the frequencies of American whites (7.5%), British whites (6.9%) and Saudis (8.5%) were lower than ours[5, 6]. It can be seen from Table 3 that the highest frequency of HLA-B alleles was B*40:01, accounting for 13.4%. Alleles were greater than 1% included B*46:01, B*58:01, B*15:01, B*13:02, B*50:01, B*13:01, B*15:02, B*55:02, B*54:01, B*38:02, B*35:01, B*39:01, B*40:06, B*40:02, B*27:04, B*52:01, B*15:11,, B*48:01, B*57:01, B*07:02, B*44:03, B*51:02, B*15:18 and B*15:27. The cumulative frequency reached 91.60%. Among them, the gene frequencies of B*40:01, B*46:01, B*58:01 were the highest, closed to those reported by F Wang et al., which were 14.0%, 11.7%, and 8.9% respectively[7]. More and more researches were reported on the correlation research between alleles of HLA-B locus and disease. We found the ratio of susceptible genes B*15:27 and B*39:01 of coronavirus disease-2019 (COVID-19) was 1.10% and 2.55% respectively, which was close to the results of 1.071–1.471% and 1.289–1.945% reported by Wei W, Wang BX [8, 9]. The mechanism of association between HLA-B alleles and diseases might be that HLA-B allele polymorphism lead to the diversity of intracellular folding and assembly characteristics and affected the diversity of CTL and NK cell-mediated immune responses [10]. It can be seen that the highest proportion of HLA-A antigens was A11, accounting for 26.7%, HLA-A antigens with gene frequency were greater than 1% included A2, A24, A33, A30, A31, A203, A26, A1, A3 and A29, with a cumulative frequency of 97.75%. Among them, the highest HLA-B antigen was B60, accounting for 12.7%, HLA-B antigens with gene frequency were greater more than 1% included B46, B13, B58, B62, B61, B75, B51, B35, B55, B27, B54, B38, B3901, B7, B48, B52, B44, B71 and B5102, with a cumulative frequency of 95.20%. Platelet cross matching is aimed to detect compatibility between platelet recipients and donors. If there is no antibody corresponding to the donor platelet in the recipient's serum, the two platelets are compatible. Platelet cross matching can solve some problems of PTR. The CCI value of platelet count is one of the indicators of the effectiveness of platelet transfusion, which has extremely important clinical significance. The platelet count was significantly increased in 18 of 20 post-transfusion clinical patients (24 h CCI ≥ 4.5 × 109/L), with obvious improvement of clinical symptoms and good hemostatic effect, which was judged that the transfusion was effective. In addition, the platelet counts of grade B1U 1 case (CCI = 3.72 × 109/L) and grade B2UX 1 case (CCI = 2.13 × 109/L) about HLA genotyping patients did not reach the expected target, so it was judged as invalid transfusion due to that the HPA typing was mismatch. In order to avoid ineffective platelet transfusion, most patients require platelet matching services to carry out platelet matching quickly and efficiently. We used serological platelet cross matching allowing most patients to obtain matched platelets, which could to solve the problem of ineffective transfusion in most patients. Data from 100 patients are provided in this paper. In clinical practice, these patients will still have ineffective platelet transfusion after platelet cross matching. At this time, we need to determine genotype and use the established gene bank to find donors to achieve the effect of accurate transfusion. PTR is a big difficult problem in clinical transfusion. The main cause of alloimmune response caused by repeated transfusion of incompatible platelets is HLA antibody, followed by platelet specific antibody (HPA). Platelet transfusion with serological matching and HLA /HPA gene matching can significantly improve the efficacy of platelet transfusion and ensure the safety and effectiveness of blood. The establishment of a database can solve the problem of ineffective platelet transfusion in some clinical patients, and understand the polymorphism characteristics of the HLA/HPA in the Chinese population, and predict the risk of ineffective platelet transfusion of the HLA/HPA related alloimmunity and provide basic data for human hematoimmunology and genetics.
  10 in total

1.  Frequency of allotype "b" in human platelet antigen 1 to 29 systems among blood donors in Japan estimated using high-resolution melt analysis.

Authors:  Tomoya Hayashi; Ryota Aminaka; Hiroyuki Ishii; Yoshihiko Tani; Yoshihiro Fujimura; Yoshihiro Takihara; Fumiya Hirayama
Journal:  Transfusion       Date:  2020-07-25       Impact factor: 3.157

2.  Frequency and causes of refractoriness in multiply transfused patients.

Authors:  T J Legler; I Fischer; J Dittmann; G Simson; R Lynen; A Humpe; J Riggert; E Schleyer; W Kern; W Hiddemann; M Köhler
Journal:  Ann Hematol       Date:  1997-04       Impact factor: 3.673

3.  HLA-A, -B, and -DRB1 genotyping and haplotype frequencies among Filipinos living in the National Capital Region of the Philippines.

Authors:  Emilio Q Villanueva; Chi-Cheng Li; Py-Yu Lin; Kuo-Liang Yang
Journal:  Hum Immunol       Date:  2020-06-19       Impact factor: 2.850

Review 4.  HLA-B polymorphisms and intracellular assembly modes.

Authors:  Malini Raghavan; Jie Geng
Journal:  Mol Immunol       Date:  2015-07-31       Impact factor: 4.407

5.  HLA-A, HLA-B, HLA-DRB1 allele and haplotype frequencies in 6384 umbilical cord blood units and transplantation matching and engraftment statistics in the Zhejiang cord blood bank of China.

Authors:  F Wang; J He; S Chen; F Qin; B Dai; W Zhang; F M Zhu; H J Lv
Journal:  Int J Immunogenet       Date:  2013-06-04       Impact factor: 1.466

6.  The IPD and IMGT/HLA database: allele variant databases.

Authors:  James Robinson; Jason A Halliwell; James D Hayhurst; Paul Flicek; Peter Parham; Steven G E Marsh
Journal:  Nucleic Acids Res       Date:  2014-11-20       Impact factor: 16.971

7.  HLA class I alleles frequencies in the Syrian population.

Authors:  Adnan M Ikhtiar; Batoul Jazairi; Issam Khansa; Ahmad Othman
Journal:  BMC Res Notes       Date:  2018-05-21

Review 8.  Susceptibility and prognosis of COVID-19 patients with cardiovascular disease.

Authors:  Brian Xiangzhi Wang
Journal:  Open Heart       Date:  2020-06

9.  Identification of 8-Digit HLA-A, -B, -C, and -DRB1 Allele and Haplotype Frequencies in Koreans Using the One Lambda AllType Next-Generation Sequencing Kit.

Authors:  Wonho Choe; Jeong-Don Chae; John Jeongseok Yang; Sang-Hyun Hwang; Sung-Eun Choi; Heung-Bum Oh
Journal:  Ann Lab Med       Date:  2021-05-01       Impact factor: 3.464

10.  Distribution of HLA allele frequencies in 82 Chinese individuals with coronavirus disease-2019 (COVID-19).

Authors:  Wei Wang; Wei Zhang; Jingjing Zhang; Ji He; Faming Zhu
Journal:  HLA       Date:  2020-06-02       Impact factor: 8.762

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.