| Literature DB >> 35664392 |
Anas H Bnaiyan1, Mohamed K Altinawi1, Thuraya Lazkani2, Hasan Alzoubi1.
Abstract
Purpose The objective of this study was to evaluate the efficacy, apical debris extrusion, and time of rotary preparation of Baby Fanta files (Fanta Dental, (Shanghai, China) in root canals of primary molars. Materials and methods The study sample consisted of 30 upper secondary molars that were randomly divided into two groups (Baby Fanta - K file, Shanghai, China), each group comprising 15 palatal roots that were prepared, the necessary preparation time was calculated, the apical debris was collected, and they underwent a clearing technique to evaluate the cleaning effectiveness of the files used in this study. Results The results showed that Baby Fanta files were superior to K-file in time of preparation (P-value=0.000) while there were no statistical differences in the effectiveness of cleaning (P-value=0.188) or apical debris extrusion (P-value=0.451). Conclusion Baby Fanta files can be used effectively for the rotary preparation of root canals in primary teeth.Entities:
Keywords: baby fanta; k-file; primary molars; pulpectomy; rotary preparation
Year: 2022 PMID: 35664392 PMCID: PMC9148183 DOI: 10.7759/cureus.24558
Source DB: PubMed Journal: Cureus ISSN: 2168-8184
Randomization results of the study sample
| Group A | Group B | ||||||||||||||||||||||||||||
| 1 | 3 | 4 | 7 | 11 | 13 | 16 | 19 | 20 | 22 | 23 | 24 | 25 | 28 | 30 | 2 | 5 | 6 | 8 | 9 | 10 | 12 | 14 | 15 | 17 | 18 | 21 | 26 | 27 | 29 |
Figure 1Study sample after standardization of the working length
Figure 2Chinese ink injection
Figure 3Example work described by the Myers and Montgomery process
Figure 4Some of the study samples after the clearing process: (A) Grade 2, (B) Grade 0, (C and D) Grade 1
Results of preparation time.
| The average preparation time for the Baby Fanta system | The average preparation time for the manual system | The difference between the two averages | Calculated t value | p-value |
| 62.20 | 118.73 | -56.53 | -21.715 | 0.000 |
Results of apical extrusion debris
| The average apical extrusion debris for the Baby Fanta system | The average apical extrusion debris for the manual system | The difference between the two averages | Calculated t value | p-value |
| 0.67 | 0.91 | -0.024 | -0.764 | 0.451 |
Results of canal cleaning according to the clearing technique
| U-value | p-value | The significance of differences |
| 87.0 | 0.188 | No statistically significant |