Literature DB >> 35660962

Retrospective analysis: 5509 cases of "totally implantable venous access port systems implantation (TIVAPS) depth" assisted by digital radiography.

Kuo Chen1, Jin Zhang2, Narasimha M Beeraka3, Yuanting Gu1, Jingruo Li1, Na Han1, Mikhail Y Sinelnikov3, Pengwei Lu4.   

Abstract

PURPOSE: Modern oncological treatment in breast cancer patients requires the precise delivery of chemotherapy infusion into the central venous systems without toxicity. TIVAPS is the significant method of chemotherapy delivery although certain internal or external complications associated with their placement. However, the long-term use of TIVAPS is still a concern to minimize the complications such as venous thrombosis syndrome (VTS) and cardiac defects. The aim of this study is to investigate the potential disadvantages that may be avoided by digital radiography (DR)-assisted measurement of catheter depth pertinent to TIVAPS implanted system.
METHODS: Retrospective analysis related to 5509 TIVAPS recipients of 99% female breast cancer patients and 1% male blood disorder patients registered from April 2013 to November 2017 were included in the study. Patients with TIVAPS catheter tip depth into superior vena cava into upper (group A), middle (group B), and lower (group C) parts were stratified for evaluation during implantation; DR-assisted measurement of TIVAPS was performed to decipher "tip depth of catheter" and determined the relevance of tip depth to complications such as VTS and cardiac defects.
RESULTS: Incidence of VTS complications were significantly higher in TIVAPS recipients of group A (82.7%) than group B (16%) and group C (0.12%) in which the "tip depth of TIVAPS was deeper" (P < 0.01). Defects in heart function are higher in group C (59.6%) than group A (15.8%) and group B (24.6%) in which the "tip depth of TIVAPS was deeper" (P < 0.01).
CONCLUSION: DR-assisted measurement can more accurately determine the depth of TIVAPS catheter implantation, and avoid the incidence of related complications, and provide a better method for surgeons.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Breast cancer; Catheter tip; Depth; Digital radiography; TIVAPS

Year:  2022        PMID: 35660962     DOI: 10.1007/s00423-022-02573-x

Source DB:  PubMed          Journal:  Langenbecks Arch Surg        ISSN: 1435-2443            Impact factor:   3.445


  2 in total

1.  Placement of a double lumen silastic catheter for hemodialysis access through the cephalic vein.

Authors:  M H Gallichio; D Kahn; N Lempert; D J Conti
Journal:  J Am Coll Surg       Date:  1994-02       Impact factor: 6.113

2.  Totally implanted venous and arterial access system to replace external catheters in cancer treatment.

Authors:  J E Niederhuber; W Ensminger; J W Gyves; M Liepman; K Doan; E Cozzi
Journal:  Surgery       Date:  1982-10       Impact factor: 3.982

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.