Echoscopy in scanning abdominal diseases in a critical care setting.

Daniel Wastl1, Axel Löwe2, Christoph F Dietrich2.   

Abstract

BACKGROUND AND AIMS: Targeted ultrasound examinations with portable ultrasound device (handheld ultrasound system [HHUS]) have been defined as "echoscopy" by the European Federation of Societies of Ultrasound in Medicine and Biology (EFSUMB). For abdominal diseases it has been shown that echoscopy is sensitive and specific. The aim of this study is to show that the use of HHUS for abdominal ultrasonography is possible under the conditions prevailing in emergency and intensive care medicine and that it is not inferior to high-end devices (high-end ultrasound systems [HEUS]).
METHODS: Examinations were carried out with a first-generation Vscan™ (GE Medical Systems, Solingen, Germany) and HEUS device (Siemens Acuson X‑300 or X‑700, Siemens Healthcare, Erlangen, Germany). The HEUS device was seen as standard. The examinations were randomized and blinded and carried out by two examiners within 30 min in order to avoid falsifications due to time delay. They took place in the intensive care unit, the emergency room and the emergency medical service. The results had to be recorded in an examination sheet.
RESULTS: In all, 86 patients (54 men and 32 women, aged 73 ± 14.58 [28-95] years) were included. In 45.35% (39/86) of the ultrasound examinations using HEUS and in 41.86% (36/89) of the cases using HHUS the examination conditions were optimal. Furthermore, 76.19% of the examinations were carried out by both examiners in the same scanning position. For the detection of liver tumours, HHUS shows a sensitivity of 70% and specificity of 100%. With regard to identifying signs of cholecystitis, i.e., evidence of surrounding inflammation (a) or hydrops (b), HHUS shows a sensitivity of 66.67% (a) and 60% (b) and a specificity of 97.06% (a) and 96.86% (b). The diagnosis of an ileus is successful with a sensitivity of 87.5% and a specificity of 60%. The respiratory variability of the inferior vena cava has a sensitivity of 100% and a specificity of 40% using HHUS. Ascites and pleural effusions can be diagnosed with a sensitivity of 89% and a specificity of 93.1%. When using the FAST (Focused Assessment with Sonography for Trauma) protocol, HHUS has a sensitivity of 80% and a specificity of 90.9%. With the exception of kidney cysts and inferior vena cava, the measurement of the diameter has a positive correlation.
CONCLUSION: Echoscopy of the abdomen in emergency and intensive care medicine is possible despite restrictive circumstances. The inferior vena cava can only be assessed to a limited extent with the first generation of Vscan™. In order to use sonography in emergency and intensive care medicine, a standardized procedure is to be aimed for and training in emergency sonography is necessary.
© 2022. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.

Entities:  

Keywords:  Emergency; Pleural effusion; Point of care; Vena cava inferior

Year:  2022        PMID: 35652927     DOI: 10.1007/s00063-022-00926-4

Source DB:  PubMed          Journal:  Med Klin Intensivmed Notfmed        ISSN: 2193-6218            Impact factor:   0.840


  2 in total

1.  The Diagnosis of Acute Cholecystitis: Sensitivity of Sonography, Cholescintigraphy and Computed Tomography.

Authors:  Patthisak Changphaisarnkul; Supakajee Saengruang-Orn; Trirat Boonya-Asadorn
Journal:  J Med Assoc Thai       Date:  2015-08

2.  Bedside ultrasound in resuscitation and the rapid ultrasound in shock protocol.

Authors:  Dina Seif; Phillips Perera; Thomas Mailhot; David Riley; Diku Mandavia
Journal:  Crit Care Res Pract       Date:  2012-10-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.