Literature DB >> 3565287

Reproducibility of cardiac stroke volume estimated by Doppler echocardiography.

H Ihlen, K Endresen, Y Myreng, E Myhre.   

Abstract

Doppler echocardiography was used to measure cardiac stroke volume in 10 patients with coronary artery disease who were treated with cardioactive drugs. Stroke volume estimates were determined at the aortic orifice by multiplying area by systolic velocity integral measured both from the suprasternal and the apical approach. Recordings were done independently by 2 experienced observers on the same day and repeated once after 1 to 21 days. Analysis of variance showed that no systematic differences were introduced by the 2 observers and Doppler approaches or by measuring on different days. The coefficient of variation between any pair of measurements in each patient was 9%. This variability is probably a result of the method or spontaneous fluctuations of the stroke volume and not of the varying recording conditions. The ultrasonic method detects day-to-day changes of cardiac stroke volume larger than 20% with a probability greater than 0.95.

Entities:  

Mesh:

Year:  1987        PMID: 3565287     DOI: 10.1016/0002-9149(87)91137-4

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  11 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Isometric exercise in the denervated heart: a Doppler echocardiographic study.

Authors:  S C Robson; S S Furniss; A Heads; R J Boys; C McGregor; R S Bexton
Journal:  Br Heart J       Date:  1989-03

3.  Reproducibility of Doppler blood flow velocity waveform measurements: study on variability within and between day and during haemodynamic intervention in normal subjects.

Authors:  G H Rimoy; N K Bhaskar; P C Rubin
Journal:  Eur J Clin Pharmacol       Date:  1991       Impact factor: 2.953

4.  Improved method for cardiac output determination in man using ultrasound Doppler technique.

Authors:  M Eriksen; L Walløe
Journal:  Med Biol Eng Comput       Date:  1990-11       Impact factor: 2.602

5.  Reproducibility of cardiac output measurement by cross sectional and Doppler echocardiography.

Authors:  S C Robson; A Murray; I Peart; A Heads; S Hunter
Journal:  Br Heart J       Date:  1988-06

Review 6.  Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: Novel techniques and new advances.

Authors:  D E Warburton; M J Haykowsky; H A Quinney; D P Humen; K K Teo
Journal:  Sports Med       Date:  1999-04       Impact factor: 11.136

7.  Cardiorespiratory and metabolic adaptations to hyperoxic training.

Authors:  L L Ploutz-Snyder; J A Simoneau; R M Gilders; R S Staron; F C Hagerman
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

8.  Cardiac stroke volume during exercise measured by Doppler echocardiography: comparison with the thermodilution technique and evaluation of reproducibility.

Authors:  H Ihlen; K Endresen; S Golf; S Nitter-Hauge
Journal:  Br Heart J       Date:  1987-11

9.  Pulmonary Artery Catheter (PAC) Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM): An Ovine Cardiac Output Validation.

Authors:  Robert A Phillips; Sally G Hood; Beverley M Jacobson; Malcolm J West; Li Wan; Clive N May
Journal:  Crit Care Res Pract       Date:  2012-05-09

10.  Global left ventricular load in asymptomatic aortic stenosis: covariates and prognostic implication (the SEAS trial).

Authors:  Ashild E Rieck; Eva Gerdts; Mai Tone Lønnebakken; Edda Bahlmann; Giovanni Cioffi; Christa Gohlke-Bärwolf; Simon Ray; Dana Cramariuc
Journal:  Cardiovasc Ultrasound       Date:  2012-11-05       Impact factor: 2.062