Literature DB >> 35648853

Geometrically engineered rigid island array for stretchable electronics capable of withstanding various deformation modes.

Jun Chang Yang1, Seungkyu Lee1, Boo Soo Ma2, Junmo Kim2, Myoung Song2, Su Yeong Kim1, Da Won Kim1, Taek-Soo Kim2, Steve Park1.   

Abstract

Integration of rigid components in soft polymer matrix is considered as the most feasible architecture to enable stretchable electronics. However, a method of suppressing cracks at the interface between soft and rigid materials due to excessive and repetitive deformations of various types remains a formidable challenge. Here, we geometrically engineered Ferris wheel-shaped islands (FWIs) capable of effectively suppressing crack propagation at the interface under various deformation modes (stretching, twisting, poking, and crumpling). The optimized FWIs have notable increased strain at failure and fatigue life compared with conventional circle- and square-shaped islands. Stretchable electronics composed of various rigid components (LED and coin cell) were demonstrated using intrinsically stretchable printed electrodes. Furthermore, electronic skin capable of differentiating various tactile stimuli without interference was demonstrated. Our method enables stretchable electronics that can be used under various geometrical forms with notable enhanced durability, enabling stretchable electronics to withstand potentially harsh conditions of everyday usage.

Entities:  

Year:  2022        PMID: 35648853      PMCID: PMC9159573          DOI: 10.1126/sciadv.abn3863

Source DB:  PubMed          Journal:  Sci Adv        ISSN: 2375-2548            Impact factor:   14.957


INTRODUCTION

Stretchable electronics enable a wide variety of previously unknown functions by offering various form factors not possible with rigid electronics (–). Recently, stretchable display (–), battery pack (–), sensor array (, , ), heater (), and logic circuit () have been demonstrated. In stretchable electronics, components (rigid devices, electrodes, and sensors) that are vulnerable to lateral strain have been designed to be protected against mechanical deformation through various geometric engineering (e.g., serpentine, rigid island, and wrinkling). Among them, the strategy of placing nonstretchable devices on the rigid island arrays minimizes the lateral strain applied to the devices because the polymer matrix surrounding islands has a relatively low elastic modulus than the island and is therefore predominantly stretched (, , ). However, the interfacial cracks between rigid islands and polymer materials due to mechanical mismatch (difference in modulus, stretchability) are likely to occur under excessive or repetitive stretching (, ), ultimately leading to crack propagation and device failure. To solve this challenge, several approaches to improving interfacial bonding strength between islands and the polymer matrix have been reported, mainly through chemical treatments (, ). However, the usable soft polymer materials are limited, and the organic chemicals are not biocompatible. Furthermore, the fabrication process is not appropriate to produce the devices on the island array because organic chemicals must be coated to specific areas. Therefore, a universal approach to enhance the mechanical stability at the interface is essential to fabricate multifunctional and stretchable electronics capable of withstanding various deformation modes. Here, we present geometrically engineered rigid islands showing excellent mechanical stability at the interface (Fig. 1A). The interlocking structure in the proposed Ferris wheel–shaped island (FWI) effectively suppresses crack propagation at the interface. The optimized geometrical shapes of FWIs depend on the mechanical properties (e.g., toughness and stretchability) of the polymer materials (e.g., Ecoflex, Dragon Skin, and Ecoflex Gel). The repetitive interlocking structure prolongs the fatigue life against various three-dimensional (3D) deformation modes such as twisting, poking, and crumpling as well as stretching in the 1D direction. Furthermore, we demonstrate several applications taking advantage of the FWI array in Ecoflex and intrinsically stretchable electrode: stretchable electronics operating under various deformations (left image in Fig. 1B) and electronic skin (e-skin) detecting tactile stimuli (right image in Fig. 1B). The proposed approach will greatly enhance the durability of stretchable electronics under practical usage, thus strengthening their commercial viability.
Fig. 1.

FWIs embedded in Ecoflex substrate for highly durable stretchable electronics.

(A) Schematic illustration of stretchable electronics with the Ferris wheel–shaped island (FWI) array in Ecoflex. (B) Left: schematic illustration of stretchable electronics operating under various deformations; right: schematic illustration of electronic skin (e-skin) detecting tactile stimuli. (C) Left: photographs of PLA islands embedded in Ecoflex; right: photographs comparing the maximum stretchability of circle-shaped island (CI) and FWI in Ecoflex substrate. The CI and FWI in Ecoflex are stretched to 75 and 175%, respectively. (D) Digital image correlation (DIC) images showing the progress of crack propagation for the CI and FWI in Ecoflex under stretching. (E) Stress versus strain for the CI (red trace) and FWI (blue trace) in Ecoflex under stretching. (F) The strain at failure according to the angle. The islands are rotated at specific angles, embedded in Ecoflex matrix, and stretched vertically. Scale bars, 1 cm (C) and 5 mm (D). Photo credit: J. C. Yang, Korea Advanced Institute of Science and Technology (KAIST).

FWIs embedded in Ecoflex substrate for highly durable stretchable electronics.

(A) Schematic illustration of stretchable electronics with the Ferris wheel–shaped island (FWI) array in Ecoflex. (B) Left: schematic illustration of stretchable electronics operating under various deformations; right: schematic illustration of electronic skin (e-skin) detecting tactile stimuli. (C) Left: photographs of PLA islands embedded in Ecoflex; right: photographs comparing the maximum stretchability of circle-shaped island (CI) and FWI in Ecoflex substrate. The CI and FWI in Ecoflex are stretched to 75 and 175%, respectively. (D) Digital image correlation (DIC) images showing the progress of crack propagation for the CI and FWI in Ecoflex under stretching. (E) Stress versus strain for the CI (red trace) and FWI (blue trace) in Ecoflex under stretching. (F) The strain at failure according to the angle. The islands are rotated at specific angles, embedded in Ecoflex matrix, and stretched vertically. Scale bars, 1 cm (C) and 5 mm (D). Photo credit: J. C. Yang, Korea Advanced Institute of Science and Technology (KAIST).

RESULTS

Fabrication and characterization of FWI embedded in Ecoflex matrix

Until now, the shapes of rigid islands have been determined according to the specific applications (table S1). In the case of stretchable display or sensor array, since the device arrangement is a square packing, the square-shaped islands (, , , –) have been mainly used. On the other hand, in the stretchable battery, hexagon- (, , ) or circle-shaped islands (CIs) (, –) have been used to increase the density of the unit cell. However, since these islands are vulnerable to interfacial crack propagation, we geometrically engineered the islands that are effective in suppressing crack propagation. 3D printing is used to manufacture various island shapes economically in a facile manner (table S2). To confirm the improved interfacial stability of the substrate with islands, 3D printed islands embedded in a polymer matrix (50 mm × 70 mm × 5 mm) were prepared using polylactic acid (PLA) (modulus: 4 GPa) () and Ecoflex (modulus: 50 kPa) () as islands and polymer, respectively (fig. S1). Under stretching, failure at the interface between the CI and the Ecoflex was observed at 75% (Fig. 1C). On the other hand, when the FWI was used, there was no substantial interfacial failure even when it was stretched at 175%. This indicates that the FWI is effective in suppressing crack propagation, thus increasing stretchability. Through inflection point (i.e., sharp drop in the stress) in the stress-strain curve (s-s curve), the strain at interfacial failure was obtained (Fig. 1E). The inflection point occurs because of the Ecoflex near the rigid islands being ruptured, which dissipates large amounts of interfacial fracture energy. The FWI, in particular, had excellent stretchability compared with various shapes generated randomly (fig. S2). Furthermore, FWI had omnidirectional stretchability, while square- and hexagon-shaped islands were easily ruptured when stretched at specific angles (Fig. 1F). To observe the progress of the crack propagation at the interface under stretching, we used digital image correlation (DIC) analysis to obtain the strain distribution of Ecoflex near and on the islands (Fig. 1D and fig. S3). At the interface of the CI, cracks appeared at a strain of 70%, and at 75% strain, the crack propagated substantially to cause interfacial failure. On the other hand, at the interface of the FWI, cracks did not occur until a strain of 180%. However, even at this strain, the anchored Ecoflex region suppresses crack propagation. It was confirmed that this crack propagation suppression effect exists even in small-scale FWI applicable to soft ultrathin electronics (fig. S4). We have also confirmed mechanical interlocking effect from the strain measurement along the polymer-island interface using DIC analysis (fig. S5). It was also confirmed that the FWI in Ecoflex was effective in suppressing crack propagation despite the presence of a preexisting crack that normally induces crack propagation (fig. S6).

The process of deriving and optimizing the design of FWI

The process of deriving the FWI is as follows (Fig. 2A): (i) Compared with square- and hexagon-shaped islands, CI has a 360° omnidirectional stretchability. (ii) Cracks at the interface of the CI easily propagate, while the periodic teeth in the windmill-shaped island (WMI) deflect the progress of cracks, thereby delaying interfacial failure. (iii) The FWI, where the mechanical interlocking structure is implemented, stops the progression of the crack by creating anchored Ecoflex regions. This interlocking effect was maximized when the ratio of the inner diameter to the outer diameter reached 0.42 (fig. S7). In addition, when several shapes of mechanical interlocking structures were formed, the strain at failure of the FWI was higher than that of WMI (fig. S8). To optimize the shape of the interlocking structure, we fabricated 16 different FWIs using the 3D printer for the design of experiments method (table S3) (). We used analysis of variance (ANOVA) to evaluate percent contribution of various design parameters [the number of teeth (n), p/i ratio, c/i ratio, and a/b ratio] to the strain at failure (Fig. 2B). As a result, the contribution of the number of teeth, p/i ratio, a/b ratio, and c/i ratio to the strain at failure were 46.43, 24.27, 19.02, and 10.28%, respectively. Therefore, it was confirmed that the number of teeth had the greatest contribution among the design parameters. To study the effect of the number of teeth of WMIs and FWIs on suppressing the progression of cracks, the strain at failure was obtained from the s-s curve (Fig. 2C and fig. S9). It was observed that the process of crack propagation was different for each shape (fig. S10).
Fig. 2.

Investigation of interfacial failure caused by crack propagation.

(A) Schematic illustration of the process of deriving FWI. (B) Percent contribution of the design factors (the number of teeth, p/i ratio, a/b ratio, and c/i ratio) to the strain at failure. (C) Experimentally obtained strain at failure for CI, WMIs (n = 6 and 12), and FWIs (n = 6 and 12). (D) Schematic illustration of FE-simulated crack propagation between islands and Ecoflex substrate. (E) Overall strain versus crack opening displacement (COD) for CI, WMI (n = 6 and 12), and FWI (n = 6 and 12). (F) FE simulation images showing the process of crack propagation when the COD reaches 2.5 mm.

Investigation of interfacial failure caused by crack propagation.

(A) Schematic illustration of the process of deriving FWI. (B) Percent contribution of the design factors (the number of teeth, p/i ratio, a/b ratio, and c/i ratio) to the strain at failure. (C) Experimentally obtained strain at failure for CI, WMIs (n = 6 and 12), and FWIs (n = 6 and 12). (D) Schematic illustration of FE-simulated crack propagation between islands and Ecoflex substrate. (E) Overall strain versus crack opening displacement (COD) for CI, WMI (n = 6 and 12), and FWI (n = 6 and 12). (F) FE simulation images showing the process of crack propagation when the COD reaches 2.5 mm. To understand the effect of island designs on the stretchability of the devices, a finite element (FE) simulation was performed. The crack propagation between the rigid island and the polymer matrix was simulated as the matrix was stretched along the uniaxial direction (Fig. 2D). The detailed procedure for the simulation is explained in Materials and Methods. To quantitatively compare the resistance to crack propagation according to the island shape, the failure criterion was set to be satisfied when crack opening displacement (COD) reached 2.5 mm (Fig. 2E). First, the CI had overall strain at fracture of 8.9%, and cracks propagated monotonically along the edge of the CI (Fig. 2F). WMI had a higher overall strain at failure value (10.7%), and crack deflection occurred at the inner corners of the teeth (fig. S11). It was considered that this complex crack path inhibits crack propagation by increasing the strain energy required for crack propagation. The FWI showed the highest overall strain at fracture among the three shapes. When cracks propagated to the anchored region inside the FWI, propagation stopped because of local compressive traction on the interface at the entrance of the anchored region. This mechanical interlocking inhibited further crack propagation and maintained the physical connection between the matrix and the island. In addition, overall strain at fracture increased as the number of teeth (n) increased because of enhanced mechanical interlocking. FWI (n = 12) showed the highest overall strain regardless of the tensile direction compared with CI or FWI (n = 6) (fig. S12). Because of the limited printing resolution, the maximum number of teeth was set to 12. To improve the stretchability of the electronic devices, rigid islands should be designed as FWI with more teeth to induce mechanical interlocking. Furthermore, we confirmed that crack propagation was suppressed even when poly(dimethylsiloxane) (PDMS)–based FWI was used instead of PLA (figs. S13 and S14). We note that, experimentally, not only delamination between the island-matrix interfaces but also a cohesive fracture in the polymer matrix occurred in the FWI samples. However, during stretching of the device, the cohesive fracture of the matrix occurred after propagation of the delamination to the entrance of the anchored region. This delamination resulted in an increase in interfacial crack opening, the amount of which was notably different between CIs, WMIs, and FWIs. The interfacial crack opening could lower device reliabilities because of loss of electrical interconnections between island and matrix. Therefore, this study focused on the delamination phenomenon using the method of virtual crack closure technique (VCCT), which is explained in detail in Materials and Methods. Further detailed optimization of the FWIs, considering the cohesive fracture in polymer matrix, was conducted through experimentation.

Compatibility of FWIs with various polymer materials

When the substrate with FWIs is stretched to the maximum, interfacial failure occurs in two modes, written as case 1 (fracture dominant) and case 2 (peeling dominant) in Fig. 3A. For case 1, the narrow region between the teeth (i.e., the neck region) fractured while the anchored region remained intact, whereas for case 2, the anchored region completely peels off of the island. Which failure mode the FWI undergoes depended on the type of polymer matrix material (Ecoflex, Dragon Skin, and Ecoflex Gel) and the p/i ratio (fig. S15). Figure 3B shows the strain at failure of the FWI with different p/i ratios in Dragon Skin. When the p/i ratio was below 0.25, the thin neck was vulnerable to fracture; hence, case 1 failure occurred (left inset image in Fig. 3B). In addition, as the p/i ratio increases, the strain at failure increases as the neck becomes thicker. On the other hand, when the p/i ratio was higher than 0.25, the neck region did not fracture; rather, the anchored region peeled off of the island (case 2) (right inset image in Fig. 3B). As the p/i ratio increases furthermore, the strain at failure decreases as the anchored region becomes easier to peel off. Therefore, at the transitioning point (p/i = 0.25), strain at failure was the maximum. Figure 3C shows the strain at failure of the FWI with different p/i ratios in Ecoflex. In the case of Ecoflex, it showed similar behavior to Dragon Skin with a transitioning point at p/i = 0.33. When Ecoflex gel, which has a relatively low toughness, was used, case 1 failure occurred at all p/i ratios (Fig. 3D). Therefore, maximum strain at failure occurs when p/i is 0.83, where the neck is the thickest. Figure 3E shows 2D drawings of FWIs with different p/i ratios. It was found that the lower the toughness of the polymer materials (fig. S16), the higher the optimum p/i ratio was. When the FWIs with optimized p/i ratios (blue bars) were used, strain at failure was improved for all three polymer types compared with that of CIs (white bars) (Fig. 3F). For this study, Ecoflex was chosen as a substrate for stretchable electronic demonstrations. Among the three materials tested (Dragon Skin, Ecoflex, and Ecoflex Gel), Ecoflex has moderate values of both modulus and stretchability, making it suitable for stretchable electronics.
Fig. 3.

Compatibility of FWIs with various polymer materials.

(A) Schematic illustration of two types of complete interfacial failure in FWI in polymer substrate. (B to D) Strain at failure according to the p/i ratio change of (B) Dragon Skin, (C) Ecoflex, and (D) Ecoflex Gel. (E) Schematic illustration of FWIs with different p/i ratios. Each box represents the optimized FWI of each polymer. (F) Experimentally obtained strain at failure for CI (white bars) and FWI (blue bars) in three different polymer matrices (Dragon Skin, Ecoflex, and Ecoflex Gel). Scale bars, 5 mm (B to D). Photo credit: J. C. Yang, KAIST.

Compatibility of FWIs with various polymer materials.

(A) Schematic illustration of two types of complete interfacial failure in FWI in polymer substrate. (B to D) Strain at failure according to the p/i ratio change of (B) Dragon Skin, (C) Ecoflex, and (D) Ecoflex Gel. (E) Schematic illustration of FWIs with different p/i ratios. Each box represents the optimized FWI of each polymer. (F) Experimentally obtained strain at failure for CI (white bars) and FWI (blue bars) in three different polymer matrices (Dragon Skin, Ecoflex, and Ecoflex Gel). Scale bars, 5 mm (B to D). Photo credit: J. C. Yang, KAIST.

Mechanical reliability of the substrate with FWIs

The effective suppression of crack propagation of FWIs not only enhances stretchability but also prolongs fatigue life. Fatigue tests were conducted on CI at 70% strain and on FWI at 120% strain, respectively (Fig. 4, A and B). In the case of CI in Ecoflex, the s-s loops shifted downward along the y axis within 100 to 140 cycles, which confirms rapid interfacial failure. On the other hand, the s-s loops of FWI in Ecoflex overlapped for 1000 cycles even at a higher strain, and no interfacial failure was observed. Figure 4C shows the relative change in the modulus [i.e., slope of the s-s curve (E) divided by the original slope (E0)] according to the number of cycles. At around 140 cycles, the E/E0 of CI drops to 0.7 because of interfacial failure, whereas for FWI, no such failure occurs. In both CI and FWI, the viscoelastic property of the Ecoflex led to mechanical hysteresis (gradual shifting along the y axis) of the s-s loops over cycles ().
Fig. 4.

FWIs in Ecoflex substrate capable of withstanding various deformation modes.

(A and B) Stress versus strain for the (A) CI and (B) FWI in Ecoflex under repeated stretching of 70 and 120% strain, respectively. (C) Relative change of modulus (E/E0) versus cycles for the CI and FWI in Ecoflex. The inset is a zoom-in of the curve at 0 to 150 cycles. (D) Photographs of twisted FWI in Ecoflex at angles of 180° and 360° under repeated stretching of 60% strain. (E) Relative change of modulus (E/E0) versus cycles for twisted CI and FWI in Ecoflex under stretching. The inset is a zoom-in of the curve at 0 to 30 cycles. (F) Photographs of FWI in Ecoflex with 60% lateral strain under repeated pressure of 10 kPa (force: 3 N). (G) Relative change of pressure (P/P0) versus cycles for the CI and FWI in Ecoflex under poking. The left inset shows that FWI is peeled off from Ecoflex after 11 cycles. The right inset is a zoom-in of the curve at 0 to 20 cycles. (H) Photographs of (top) CI and (bottom) FWI array in Ecoflex placed inside a cylinder. Both island arrays are repeatedly crumpled vertically 100 times with pressure of 35 kPa. In the CI array, cracks are rapidly expanded at the interface between islands and the Ecoflex. On the other hand, no visible crack propagation occurs in the FWI array. Scale bars, 2 cm (D) and 1 cm (F and H). Photo credit: S. Lee, KAIST.

FWIs in Ecoflex substrate capable of withstanding various deformation modes.

(A and B) Stress versus strain for the (A) CI and (B) FWI in Ecoflex under repeated stretching of 70 and 120% strain, respectively. (C) Relative change of modulus (E/E0) versus cycles for the CI and FWI in Ecoflex. The inset is a zoom-in of the curve at 0 to 150 cycles. (D) Photographs of twisted FWI in Ecoflex at angles of 180° and 360° under repeated stretching of 60% strain. (E) Relative change of modulus (E/E0) versus cycles for twisted CI and FWI in Ecoflex under stretching. The inset is a zoom-in of the curve at 0 to 30 cycles. (F) Photographs of FWI in Ecoflex with 60% lateral strain under repeated pressure of 10 kPa (force: 3 N). (G) Relative change of pressure (P/P0) versus cycles for the CI and FWI in Ecoflex under poking. The left inset shows that FWI is peeled off from Ecoflex after 11 cycles. The right inset is a zoom-in of the curve at 0 to 20 cycles. (H) Photographs of (top) CI and (bottom) FWI array in Ecoflex placed inside a cylinder. Both island arrays are repeatedly crumpled vertically 100 times with pressure of 35 kPa. In the CI array, cracks are rapidly expanded at the interface between islands and the Ecoflex. On the other hand, no visible crack propagation occurs in the FWI array. Scale bars, 2 cm (D) and 1 cm (F and H). Photo credit: S. Lee, KAIST. The FWI with strong horizontal crack propagation resistance also contributed to the mechanical stability under various 3D deformations. Fatigue tests were performed on CI and FWI under twisting, poking, and crumpling. To verify the mechanical stability of FWIs under twisting, a cyclic tensile strain of 60% was applied to the CI and FWI in Ecoflex twisted at specific angles (180° and 360°) (Fig. 4D and fig. S17). Figure 4E shows the change in the modulus according to the cycles. Under cyclic stretching at 180° for CI in Ecoflex, the E/E0 decreased to 0.9 within 20 to 25 cycles, signifying interfacial failure (fig. S18A). Figure S18B shows the failure at the interface immediately upon twisting at 360° for CI in Ecoflex even without applying strain. On the other hand, the E/E0 of FWI in Ecoflex twisted at 180° and 360° remains relatively constant, indicating a highly stable structure under twisting (fig. S18, C and D). The initial decrease in E/E0 is due to the viscoelastic property of the Ecoflex. To investigate the resistance to crack propagation when stress is applied along the thickness of the substrate (i.e., applying shear stress by poking), cyclic pressure of 10 kPa (compressive force: 3 N, depth: 1.6 cm) was applied to the CI and FWI in Ecoflex (suspended in air) at 60% lateral strain (Fig. 4F and fig. S19). Figure 4G shows the change in the pressure (P/P0) according to the number of cycles. For CI in Ecoflex, interfacial crack easily propagated, resulting in an immediate decrease in pressure. The inset image in Fig. 4G shows the fractured CI in Ecoflex at the 11th cycle. The FWI in Ecoflex exhibited a slight decrease in P/P0 up to 50 cycles, which is due to the viscoelastic property of the Ecoflex. Thereafter, the FWI in Ecoflex was stable without interfacial failure up to 1000 cycles. This result shows that FWI also impedes failure along the thickness of the substrate. To test failure under crumpling mode, we first fabricated CI and FWI (thickness: 1 mm) array (3 × 3) embedded in Ecoflex. The island arrays were placed inside a cylinder and repeatedly crumpled vertically 100 times with pressure of 35 kPa (force: 70 N) (Fig. 4H). Top of Fig. 4H shows that in the case of CI, cracks rapidly expanded at the interface between islands and the Ecoflex. On the other hand, no visible crack propagation occurred in the case of FWI (bottom of Fig. 4H). In summary, the fatigue tests for stretching, twisting, poking, and crumpling suggest that the FWI suppresses crack propagation at the interface even when repetitive external force of various types is applied. These results signify that, through our geometrical design, stretchable electronics can potentially gain degrees of freedom to different deformations, thus propelling stretchable electronics toward many practical applications operated under harsh conditions.

Stretchable electronics with rigid components

Previously, rigid islands and various serpentine electrodes have been used to integrate conventional rigid components into stretchable electronics (, , ). Serpentine electrodes are vulnerable to repetitive deformation because of weak interface with the polymer matrix and due to its intrinsic brittleness. Therefore, for the devices to operate stably under various repeated deformations, Ag flake/Ecoflex composite (), which is an intrinsically stretchable electrode, was used (Fig. 5A and Materials and Methods). The composite solution containing 82 weight % of Ag flakes with respect to Ecoflex was screen printed on Ecoflex substrate with and without islands through a metal mask. It was confirmed that the electrode on the Ecoflex substrate without island has high initial electrical conductivity of 400 S/cm and high stretchability of 295% (Fig. 5B). Compared with the CI in Ecoflex, the electrode coated on the FWI in Ecoflex maintained low resistance at a higher strain (27 ohms at 220% strain) due to its high interfacial stability. In addition, the stretchable electrode on the FWI in Ecoflex maintained low resistance even at 1000 cycles (fig. S20). To fabricate stretchable electronics, FWIs were prepared in the form of an array; here, the spacing between the islands determined the maximum stretchability of the array (fig. S21). To produce a stretchable light-emitting diode (LED) array, an FWI array of 3 × 3 in Ecoflex was prepared with a center-to-center distance of 25 mm between the islands (Fig. 5C and Materials and Methods). Then, stretchable electrodes were printed, followed by the placement of surface mount device (SMD) LED chips on each FWI and fixation with PDMS prepolymer solution. When PDMS was cured by heating, chips were tightly bonded to each FWI. Last, the exposed electrodes were encapsulated with Ecoflex. The manufactured stretchable LED array worked well under all deformation modes, including stretching, twisting, crumpling, and bending (Fig. 5D and movie S1). Next, to manufacture a stretchable battery pack, two arrays were prepared in which seven FWIs were hexagonally arranged (), with a center-to-center distance of 30 mm between the islands (Fig. 5E and Materials and Methods). Stretchable electrodes were printed to electrically connect the FWIs in both arrays. Coin cells were sandwiched between these two arrays with PDMS fixation and Ecoflex encapsulation, as depicted in the side-view schematic of Fig. 5E. The manufactured stretchable battery pack powered the LED under various deformation modes, including stretching, twisting, crumping, and bending (Fig. 5F and movie S2). Such freeform electronics is expected to increase user convenience and durability under practical usage.
Fig. 5.

Stretchable electronics consisting of rigid components capable of withstanding various deformation modes.

(A) Schematic illustration, photograph, and SEM image of stretchable Ag flake/Ecoflex electrodes printed on the FWI in Ecoflex substrate. (B) Resistance versus lateral strain for the Ag flake/Ecoflex electrodes printed on CI and FWI in Ecoflex. The left inset shows that the electrode printed on CI in Ecoflex was disconnected at 50%. The middle and right insets show that the electrode printed on FWI in Ecoflex was connected at 125 and 220%, respectively. (C and E) Schematic illustration and photograph of (C) a stretchable LED array and (E) stretchable battery pack with FWIs. The encapsulation layer is Ecoflex. (D and F) Photographs of (D) the stretchable LED array and (F) the stretchable battery pack capable of withstanding various deformation modes (twisting, bending, stretching, and crumpling). Scale bars, 1 cm [(A), left image], 10 μm [(A), right image], 3 cm (C), and 4 cm (E). Photo credit: J. C. Yang, KAIST.

Stretchable electronics consisting of rigid components capable of withstanding various deformation modes.

(A) Schematic illustration, photograph, and SEM image of stretchable Ag flake/Ecoflex electrodes printed on the FWI in Ecoflex substrate. (B) Resistance versus lateral strain for the Ag flake/Ecoflex electrodes printed on CI and FWI in Ecoflex. The left inset shows that the electrode printed on CI in Ecoflex was disconnected at 50%. The middle and right insets show that the electrode printed on FWI in Ecoflex was connected at 125 and 220%, respectively. (C and E) Schematic illustration and photograph of (C) a stretchable LED array and (E) stretchable battery pack with FWIs. The encapsulation layer is Ecoflex. (D and F) Photographs of (D) the stretchable LED array and (F) the stretchable battery pack capable of withstanding various deformation modes (twisting, bending, stretching, and crumpling). Scale bars, 1 cm [(A), left image], 10 μm [(A), right image], 3 cm (C), and 4 cm (E). Photo credit: J. C. Yang, KAIST.

E-skin with pressure and strain sensors

For practical usability of e-skin toward various applications such as virtual reality/augmented reality, human-machine interface, health monitoring, and robotics (, –), it is of critical importance to differentiate physical stimuli without signal interference while ensuring high durability under repeated and excessive mechanical deformations. Using FWI array in Ecoflex, e-skin that can differentiate physical signals under various deformation modes was demonstrated (Fig. 6A). Four polypyrrole-coated micropyramidal PDMS-based piezoresistive pressure sensors (, ) were placed on the FWIs, and two porous carbon nanotube (CNT)/Ecoflex composite–based piezoresistive strain sensors () were coated on the Ecoflex (see Materials and Methods and figs. S22 and S23). Scanning electron microscopy (SEM) images confirm microstructures of the pressure and strain sensors (fig. S24). The piezoresistive pressure sensors detect pressure levels through the change in contacting area between two lateral electrodes and the polypyrrole-coated micropyramidal PDMS (fig. S25A). The pressure sensors not placed on FWIs were subject to electrical interference under lateral strain (fig. S25B). Pressure sensors placed on CIs have reduced signal interference because of lateral strain; however, they lack practical feasibility because of the disconnection of the electrodes under high strain (Fig. 6B). The pressure sensors on FWIs, on the contrary, measured the same pressure without the interference even under strain up to 150%. Furthermore, the two piezoresistive strain sensors coated on the Ecoflex of substrate accurately detected lateral strain in the x axis and y axis directions. In particular, our strain sensor was designed to be insensitive to pressure (fig. S26) (). For demonstration toward health care monitoring, our e-skin was attached to a human forearm to detect human pulse from a pressure sensor (Fig. 6C). The measured pulse rate was 69 beats min−1. The p-, t-, and d-waves in the waveform of radial artery pulse were matched with the subject’s age of 29 (, ). The average values of digital volume pulse time (ΔTDVP = tP2 − tP1), radial augmentation index (AIr = P2/P1), and diastolic augmentation index (DAIr = P3/P1) were 0.188, 0.840, and 0.530, respectively. These values can be used for health care monitoring. In addition, information on daily movements can be collected and used for health care monitoring through the strain sensor attached to the knee (Fig. 6D). Complex tactile stimuli with simultaneous input of strain and pressure were effectively decoupled in real time when our e-skin was attached to the skin and when held with hands (Fig. 6E). Furthermore, our e-skin produced the same sensor signal even at 1000 cycles (fig. S27).
Fig. 6.

E-skin distinguishing pressure and lateral strain.

(A) Schematic illustration of e-skin consisting of polypyrrole-coated micropyramidal PDMS-based pressure sensors and porous CNT/Ecoflex-based strain sensors. The area within the red dotted line is isolated from lateral strain. (B) Sensing characteristics of pressure sensors placed on the region of CI and FWI in Ecoflex under stretching. The pressure sensor on the CI does not work because of the electrically disconnected electrode at 70% strain. (C) A radial artery pulse signal detected by the pressure sensor. (D) A signal due to bending of the knee detected by the strain sensor. (E) Real-time monitoring of pressure and lateral strain in various deformations: (i) pressure on the substrate and (ii) stretching the substrate along the x axis and pressure on the biaxial-stretched substrate. Photo credit: J. C. Yang, KAIST.

E-skin distinguishing pressure and lateral strain.

(A) Schematic illustration of e-skin consisting of polypyrrole-coated micropyramidal PDMS-based pressure sensors and porous CNT/Ecoflex-based strain sensors. The area within the red dotted line is isolated from lateral strain. (B) Sensing characteristics of pressure sensors placed on the region of CI and FWI in Ecoflex under stretching. The pressure sensor on the CI does not work because of the electrically disconnected electrode at 70% strain. (C) A radial artery pulse signal detected by the pressure sensor. (D) A signal due to bending of the knee detected by the strain sensor. (E) Real-time monitoring of pressure and lateral strain in various deformations: (i) pressure on the substrate and (ii) stretching the substrate along the x axis and pressure on the biaxial-stretched substrate. Photo credit: J. C. Yang, KAIST.

DISCUSSION

For practical use of stretchable electronics in the future, it is of high importance to ensure high durability under potentially harsh conditions that the devices can be exposed to under everyday usage. In this sense, simple lateral strain testing is insufficient to qualify stretchable electronics toward practical applications. To bridge this gap, we developed FWIs with strong mechanical stability at the interface with soft polymer. Because of suppression of interfacial crack propagation by the interlocking structure, the FWI improved strain at failure under stretching and prolonged fatigue life under various deformation modes (stretching, twisting, poking, and crumpling). Various design parameters of FWI have a great influence on the mechanical stability of the substrate and depend on the mechanical properties of polymer materials. For practical demonstrations of stretchable electronics, we printed intrinsically stretchable electrodes and placed rigid components (LED and coin cell) on the FWI arrays. Furthermore, we fabricated e-skin capable of differentiating various physical stimuli. Our technique can be generally applied to a wide variety of stretchable electronics to impart high durability under various deformation modes, thus bringing stretchable electronics closer to commercialization in the near future.

MATERIALS AND METHODS

Fabrication of rigid island with various shapes embedded in polymer matrix

PLA islands with various shapes (table S2) were manufactured with a 3D printer (Ultimaker 2+, USA). The type of printer is fused deposition modeling technology. The diameter of the island was 20 mm. The height of the island used in Figs. 1 to 4, and 5 and 6 were 5 and 1 mm, respectively. Ecoflex 00-20 (Smooth-On), Dragon Skin 10 NV (Smooth-On), and Ecoflex Gel (Smooth-On) were used for the elastic polymer matrix. The part A and part B of the Ecoflex series (Ecoflex, Dragon Skin, and Ecoflex Gel) in a 1:1 weight ratio were mixed with a planetary mixer (Thinky AR-100) to perform a mixing time of 2 min and a deformation time of 30 s. The PLA islands were placed on the mold, and the prepolymer solution was poured equal to the height of the island. The curing conditions for Ecoflex Gel were 3 hours at room temperature. The curing conditions for Ecoflex and Dragon Skin were 1 hour at 80°C. In all cases except for Fig. 3, Ecoflex was used as the polymer matrix. After the curing process, the samples were prepared by cutting polymer matrices into 50 mm × 70 mm × 5 mm.

Fabrication of intrinsically stretchable electrode

The previously reported Ag flake/Ecoflex composite–based electrode was used (). First, MIBK (4-methyl-2-pentanone) (Sigma-Aldrich), Ecoflex prepolymer solution, and Ag flakes (Daejoo Electronic Materials) were mixed in a 3:3:14 ratio with a planetary mixer to perform a mixing time of 2 min and a deformation time of 30 s. Afterward, the Ag flake/Ecoflex composite solution was screen printed on the CIs and FWIs in Ecoflex substrate to a thickness of 200 μm through a metal mask. The heating condition was 1 hour in 80°C and 2 hours 30 min in 110°C. The MIBK solvent was evaporated at 80°C, and conductivity was achieved through thermal sintering of the composite at 110°C.

Fabrication of stretchable LED array and stretchable battery pack

To fabricate a stretchable LED array, an FWI (thickness: 1 mm) array of 3 × 3 was placed on the mold in square packing. The Ecoflex prepolymer solution was poured equal to the height of the island. The center-to-center distance between the islands was 25 mm. Ag flake/Ecoflex composite was screen printed on the FWIs in Ecoflex substrate to a thickness of 200 μm through a metal mask. Afterward, the SMD LED chips (5 V; GrinMax) were attached to the island. Then, SMD LED chips were placed on each FWI and fixed with PDMS. The exposed electrodes were encapsulated with Ecoflex. Next, to manufacture a stretchable battery pack, two arrays were prepared in which seven FWIs (thickness: 1 mm) were hexagonally arranged with a center-to-center distance of 30 mm between the islands. The process of manufacturing arrays with electrodes was the same as that of the stretchable LED array. Then, lithium coin cells (3 V; Panasonic) were sandwiched between these two arrays with PDMS fixation and Ecoflex encapsulation. To operate the stretchable LED array and stretchable battery pack, Ag-coated mesh (Shieldex) was connected to Ag flake/Ecoflex and encapsulated with Ecoflex. To turn on the LEDs, the voltage was applied to the stretchable LED array through a source meter (Keithley 2400, Tektronix Inc.). The stretchable battery pack was connected to the diode.

Fabrication of e-skin

FWI (thickness: 1 mm) array of 2 × 2 embedded in Ecoflex (100 × 100 mm) was prepared (figs. S22 and S23). The process of manufacturing arrays with electrodes was the same as that of the stretchable LED array. To fabricate the e-skin, polypyrrole-coated micropyramidal PDMS and porous CNT/Ecoflex composite were prepared as pressure and strain sensors, respectively. We prepared the polypyrrole-coated micropyramidal PDMS following the previously reported work (, ). The base width, edge-to-edge spacing, and height of the pyramids were 100, 100, and 70 μm, respectively. The width and length of the micropyramidal PDMS layer are 15 and 15 mm, respectively. The polypyrrole-coated micropyramidal PDMS was lastly placed on top of electrodes in FWIs. The length and width between lateral electrodes were 7 and 1 mm, respectively. Next, we prepared the porous CNT/Ecoflex following the previously reported work with little modification (). The Ecoflex prepolymer solution was mechanically mixed with hexane in a weight ratio of 1:2 to lower the viscosity. The Ecoflex prepolymer solution was used instead of the PDMS prepolymer solution, and the fabrication process was the same as in previously reported work. The CNT/Ecoflex solution was screen printed on the Ecoflex region of the substrate. The width and length of the CNT/Ecoflex layer are 5 and 40 mm, respectively. To operate the e-skin, Ag-coated meshes (Shieldex) were connected to stretchable electrodes and encapsulated with Ecoflex.

DIC analysis

Strain distribution on the surface of the stretchable substrate specimens was calculated and analyzed using a commercial DIC algorithm program (ARAMIS, Gesellschaft für Optische Messtechnik mbH) during a tensile test with 0.005% error for strain measurement. Analyzed images were captured at 3 Hz by two charge-coupled device (CCD) cameras (6 million pixels), which were calibrated to measure the proper area (170 × 110 mm). CCD cameras and commercial software were calibrated to measure a large enough area to capture the images of 100%-stretched specimens (fig. S28). We applied the interpolation method at the boundary of the island, which calculates strain as the average of the island and the matrix region. Both black and white speckle patterns were randomly generated on both the matrix and the island simultaneously by commercial lackspray (Dupli-Color, Germany).

FE simulation

The interfacial crack propagation process for various shapes was simulated using a commercial FE method tool (Abaqus version 6.14-3). The island, matrix, and grips at both ends were modeled as a deformable 2D shell. The element type of the components was CPS4R (four-node bilinear, reduced integration with hourglass control) (fig. S29). The island was bonded to the matrix based on the VCCT model with uniformly distributed microcracks at the outermost interface, under the assumption that the interfacial fracture energy is much smaller than the cohesive fracture energy of the matrix. The island was modeled to be a rigid body with various shapes (circle, windmill, and Ferris wheel), with an outer diameter of 10 mm. The matrix was drawn to dimensions of 50 mm wide and 100 mm long.

Tensile test and fatigue test

Tensile test and fatigue test were performed on CIs and FWIs using a force gauge (maximum force: 100 N, Mark-10) and a stand with a motor (Mark-10). In all the tests, the strain speed of the motor was 200 mm/min. In the fatigue test under twisting, repetitive stretching was applied to the twisted substrate. In the fatigue test under poking, repetitive pressure was applied to the stretched substrate. To test the crumpling mode, an FWI (thickness: 1 mm) array of 3 × 3 embedded in Ecoflex was prepared. The center-to-center distance between the islands was 25 mm. The island arrays were placed inside of a cylinder and repeatedly crumpled vertically 100 times with pressure of 35 kPa (force: 70 N).

Measurement of electrical properties

The resistance of the stretchable electrode, pressure sensor, and strain sensor was measured using an inductance capacitance and resistance (LCR) meter (4284A, HP) at 1-V voltage and 1-kHz frequency. In Fig. 6E, we used Arduino to obtain pressure and lateral strain signals simultaneously in real time (fig. S23C). All experiments on human skin were not subject to local ethics committee approval because noninvasive measurement of skin was conducted.
  26 in total

1.  Pressure Insensitive Strain Sensor with Facile Solution-Based Process for Tactile Sensing Applications.

Authors:  Jinwon Oh; Jun Chang Yang; Jin-Oh Kim; Hyunkyu Park; Se Young Kwon; Serin Lee; Joo Yong Sim; Hyun Woo Oh; Jung Kim; Steve Park
Journal:  ACS Nano       Date:  2018-07-16       Impact factor: 15.881

2.  How To Optimize Materials and Devices via Design of Experiments and Machine Learning: Demonstration Using Organic Photovoltaics.

Authors:  Bing Cao; Lawrence A Adutwum; Anton O Oliynyk; Erik J Luber; Brian C Olsen; Arthur Mar; Jillian M Buriak
Journal:  ACS Nano       Date:  2018-07-20       Impact factor: 15.881

3.  Soft microfluidic assemblies of sensors, circuits, and radios for the skin.

Authors:  Sheng Xu; Yihui Zhang; Lin Jia; Kyle E Mathewson; Kyung-In Jang; Jeonghyun Kim; Haoran Fu; Xian Huang; Pranav Chava; Renhan Wang; Sanat Bhole; Lizhe Wang; Yoon Joo Na; Yue Guan; Matthew Flavin; Zheshen Han; Yonggang Huang; John A Rogers
Journal:  Science       Date:  2014-04-04       Impact factor: 47.728

4.  Skin electronics from scalable fabrication of an intrinsically stretchable transistor array.

Authors:  Sihong Wang; Jie Xu; Weichen Wang; Ging-Ji Nathan Wang; Reza Rastak; Francisco Molina-Lopez; Jong Won Chung; Simiao Niu; Vivian R Feig; Jeffery Lopez; Ting Lei; Soon-Ki Kwon; Yeongin Kim; Amir M Foudeh; Anatol Ehrlich; Andrea Gasperini; Youngjun Yun; Boris Murmann; Jeffery B-H Tok; Zhenan Bao
Journal:  Nature       Date:  2018-02-19       Impact factor: 49.962

Review 5.  Electronic Skin: Recent Progress and Future Prospects for Skin-Attachable Devices for Health Monitoring, Robotics, and Prosthetics.

Authors:  Jun Chang Yang; Jaewan Mun; Se Young Kwon; Seongjun Park; Zhenan Bao; Steve Park
Journal:  Adv Mater       Date:  2019-09-19       Impact factor: 30.849

Review 6.  25th anniversary article: The evolution of electronic skin (e-skin): a brief history, design considerations, and recent progress.

Authors:  Mallory L Hammock; Alex Chortos; Benjamin C-K Tee; Jeffrey B-H Tok; Zhenan Bao
Journal:  Adv Mater       Date:  2013-10-22       Impact factor: 30.849

7.  Stretchable Hydrogel Electronics and Devices.

Authors:  Shaoting Lin; Hyunwoo Yuk; Teng Zhang; German Alberto Parada; Hyunwoo Koo; Cunjiang Yu; Xuanhe Zhao
Journal:  Adv Mater       Date:  2015-12-07       Impact factor: 30.849

8.  From Playroom to Lab: Tough Stretchable Electronics Analyzed with a Tabletop Tensile Tester Made from Toy-Bricks.

Authors:  Richard Moser; Gerald Kettlgruber; Christian M Siket; Michael Drack; Ingrid M Graz; Umut Cakmak; Zoltan Major; Martin Kaltenbrunner; Siegfried Bauer
Journal:  Adv Sci (Weinh)       Date:  2016-01-13       Impact factor: 16.806

9.  Haptic-feedback smart glove as a creative human-machine interface (HMI) for virtual/augmented reality applications.

Authors:  Minglu Zhu; Zhongda Sun; Zixuan Zhang; Qiongfeng Shi; Tianyiyi He; Huicong Liu; Tao Chen; Chengkuo Lee
Journal:  Sci Adv       Date:  2020-05-08       Impact factor: 14.136

10.  Standalone real-time health monitoring patch based on a stretchable organic optoelectronic system.

Authors:  Yeongjun Lee; Jong Won Chung; Gae Hwang Lee; Hyunbum Kang; Joo-Young Kim; Chisung Bae; Hyunjun Yoo; Sujin Jeong; Hyeon Cho; Sung-Gyu Kang; Ji Young Jung; Don-Wook Lee; Sangah Gam; Suk Gyu Hahm; Yasutaka Kuzumoto; Sang Joon Kim; Zhenan Bao; Yongtaek Hong; Youngjun Yun; Sunghan Kim
Journal:  Sci Adv       Date:  2021-06-04       Impact factor: 14.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.