Literature DB >> 3564868

Preservation of humidity and heat of respiratory gases during anaesthesia--a laboratory investigation.

J P Bengtson, H Sonander, O Stenqvist.   

Abstract

Humidification and heating of anaesthetic gases are desirable to prevent respiratory tract damage and a fall in body temperature during operative procedures. Numerous studies on the humidity and temperature of inspiratory gases in different breathing systems for anaesthesia have been carried out, but comparisons are difficult since different methods have been used. In this laboratory set-up we studied a non-rebreathing system with and without humidifiers and a circle absorber system with low (0.5 l/min) or medium (5 l/min) fresh gas flows regarding their ability to heat and humidify anaesthetic gases. The humidity of inspired gases was acceptable in the non-rebreathing system using either a Bennett Cascade humidifier or disposable humidifiers and in the circle absorber system using a fresh gas flow of 5 l/min or less. The temperature of the inspired gases was highest with the Bennett Cascade humidifier, followed by the low-flow circle system. The circle absorber system used with low fresh gas flow gave higher inspiratory gas temperature and humidity than the non-rebreathing system with a good disposable humidifier.

Entities:  

Mesh:

Year:  1987        PMID: 3564868     DOI: 10.1111/j.1399-6576.1987.tb02534.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  5 in total

Review 1.  Low-flow anaesthesia. Does it have potential pharmacoeconomic consequences?

Authors:  S Suttner; J Boldt
Journal:  Pharmacoeconomics       Date:  2000-06       Impact factor: 4.981

2.  The effect of heat-moisture exchanger and closed-circuit technique on airway climate during desflurane anesthesia.

Authors:  Chih-Cherng Lu; Shung-Tai Ho; Wen-Jinn Liaw; Ruei-Ming Chen; Ta-Liang Chen; Chung-Yuan Lin
Journal:  J Anesth       Date:  2008-02-27       Impact factor: 2.078

3.  Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials.

Authors:  Yoon Ji Choi; Sam Hong Min; Jeong Jun Park; Jang Eun Cho; Seung Zhoo Yoon; Suk Min Yoon
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

4.  A randomized prospective study of desflurane versus isoflurane in minimal flow anesthesia using "equilibration time" as the change-over point to minimal flow.

Authors:  Tanuja Mallik; S Aneja; R Tope; V Muralidhar
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2012-10

5.  Analyzing Volatile Anesthetic Consumption by Auditing Fresh Gas Flow: An Observational Study at an Academic Hospital.

Authors:  Luis Tollinche; KaySee Tan; Austin Han; Leslie Ojea; Cindy Yeoh
Journal:  Int J Anesth Anesth       Date:  2018-04-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.