Literature DB >> 35642238

Parameters Used With Diode Lasers (808-980 nm) in Dentin Hypersensitivity Management: A Systematic Review.

Haitham Abdelkarim-Elafifi1,2, Isabel Parada-Avendaño3, Josep Arnabat-Domínguez1,4.   

Abstract

Introduction: The present study aimed to describe parameters used with 808- to 980-nm wavelength diode lasers for managing dentin hypersensitivity and analyze their results.
Methods: The inclusion criteria were based on randomized controlled clinical trials using diode lasers at an 808-980 nm wavelength range in patients with dentine hypersensitivity with a minimum of 1-month follow-up. An electronic search for articles on Medline, PubMed and Cochrane databases was performed. The risk of bias was assessed with the Cochrane collaboration tool.
Results: Our electronic search resulted in 130 papers, of which 11 articles met the inclusion criteria. A majority of the studies assessed dentine hypersensitivity using the Visual Analogue Scale, which ranged between 2.3 and 8.8 before treatment and significantly reduced to a mean value of 0.45-3.7 after diode laser application. The power settings ranged between 1.5 mW and 3 W with an emission mode of continuous wave, except for 2 authors who used chopped mode. The energy density varied from 2.5 to 128 J/cm2, and the exposure time was between 10 and 120 seconds. The authors applied a minimum of 1 to 4 treatment sessions with a 2-day to 1-week interval between them. Most of the studies mentioned the tooth surface as the treatment site but without describing the specific irradiation points.
Conclusion: Despite the heterogeneity of the analyzed variables, a statistically significant improvement in all laser groups was described. However, they cannot be compared homogenously.
Copyright © 2022 J Lasers Med Sci.

Entities:  

Keywords:  Dentin hypersensitivity; Dentistry; Diode laser; Laser therapy

Year:  2022        PMID: 35642238      PMCID: PMC9131297          DOI: 10.34172/jlms.2022.03

Source DB:  PubMed          Journal:  J Lasers Med Sci        ISSN: 2008-9783


  28 in total

1.  How to report low-level laser therapy (LLLT)/photomedicine dose and beam parameters in clinical and laboratory studies.

Authors:  Peter A Jenkins; James D Carroll
Journal:  Photomed Laser Surg       Date:  2011-11-22       Impact factor: 2.796

2.  Short-term Efficacy of Agents Containing KNO3 or CPP-ACP in Treatment of Dentin Hypersensitivity.

Authors:  Adalaiti Mahesuti; Yin Ling Duan; Ge Wang; Xiang Rong Cheng; Bruce A Matis
Journal:  Chin J Dent Res       Date:  2014

3.  Desensitizing efficacy of nano-carbonate apatite dentifrice and Er,Cr:YSGG laser: a randomized clinical trial.

Authors:  Su-Young Lee; Hoi-In Jung; Bock-Young Jung; Young-Sik Cho; Ho-Keun Kwon; Baek-Il Kim
Journal:  Photomed Laser Surg       Date:  2015-01       Impact factor: 2.796

4.  How to Write a Good Photobiomodulation Article.

Authors:  Michael R Hamblin
Journal:  Photobiomodul Photomed Laser Surg       Date:  2019-05-17

5.  A cross-sectional study of dentine hypersensitivity.

Authors:  J S Rees; M Addy
Journal:  J Clin Periodontol       Date:  2002-11       Impact factor: 8.728

6.  Evaluation of the Effects of 660-nm and 810-nm Low-Level Diode Lasers on the Treatment of Dentin Hypersensitivity.

Authors:  Narges Naghsh; Mahdi Kachuie; Marzie Kachuie; Reza Birang
Journal:  J Lasers Med Sci       Date:  2020-03-15

7.  Clinical evaluation of Er,Cr:YSGG and GaAlAs laser therapy for treating dentine hypersensitivity: A randomized controlled clinical trial.

Authors:  Hasan Guney Yilmaz; Sevcan Kurtulmus-Yilmaz; Esra Cengiz; Hakan Bayindir; Yasar Aykac
Journal:  J Dent       Date:  2011-01-14       Impact factor: 4.379

8.  Long-term effect of diode laser irradiation compared to sodium fluoride varnish in the treatment of dentine hypersensitivity in periodontal maintenance patients: a randomized controlled clinical study.

Authors:  Hasan Guney Yilmaz; Sevcan Kurtulmus-Yilmaz; Esra Cengiz
Journal:  Photomed Laser Surg       Date:  2011-06-13       Impact factor: 2.796

9.  Dentinal tubules sealing by means of diode lasers (810 and 980 nm): a preliminary in vitro study.

Authors:  Monica Umana; Daniel Heysselaer; Marc Tielemans; Philippe Compere; Toni Zeinoun; Samir Nammour
Journal:  Photomed Laser Surg       Date:  2013-06-11       Impact factor: 2.796

10.  Low-level Laser Therapy in Combination with Desensitising Agent Reduces Dentin Hypersensitivity in Fluorotic and Non-fluorotic Teeth - A Randomised, Controlled, Double-blind Clinical Trial.

Authors:  Roopalakshmi Narayanan; Munivenkatappa Lakshmaiah Venkatesh Prabhuji; Rashmi Paramashivaiah; Shaeesta Khaleelahmed Bhavikatti
Journal:  Oral Health Prev Dent       Date:  2019       Impact factor: 1.256

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.