Literature DB >> 3563893

Long-term biologic fate of neoarteries regenerated in microporous, compliant, biodegradable, small-caliber vascular grafts in rats.

B van der Lei, P Nieuwenhuis, I Molenaar, C R Wildevuur.   

Abstract

Microporous, compliant, biodegradable vascular grafts prepared from a mixture of polyurethane [( PU], 95% weight) and poly-L-lactide [( PLLA] 5% weight) can function as temporary scaffolds for the regeneration of the arterial wall of small-caliber arteries. The purpose of this study was to determine the long-term biologic fate of these neoarteries that were regenerated in PU/PLLA vascular grafts. The PU/PLLA vascular grafts (1.5 mm internal diameter [ID]) were implanted into the abdominal aortas of rats (N = 8) and were evaluated 1 year after implantation by means of macroscopic inspection, light microscopy, and electron microscopy. All implants were patent; three implants were normally shaped, two were slightly dilated (+/- 10% of the original ID), and three implants were aneurysmal. Arterial pulsations were reduced but still visible in the normally shaped implants and absent in the other implants. In all implants, the neointima was complete. The neomedia varied among the implants: In the normally shaped implants, smooth muscle cells were predominantly circularly arranged as in normal arterial tissue; in the other implants, smooth muscle cells were predominantly longitudinally arranged. The neoadventitia showed a completely fragmented graft lattice, which was organized by fibrohistiocytic tissue. These results suggest that the pattern of arrangement of smooth muscle cells in the neomedia determines the ultimate biologic fate of neoarteries regenerated in microporous, compliant, biodegradable vascular grafts. Only those neoarteries with predominantly circularly arranged smooth muscle cells in the neomedia were able to function normally as an arterial substitute for a 1-year period after implantation into the rat abdominal aorta.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3563893

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  5 in total

Review 1.  Designer blood vessels and therapeutic revascularization.

Authors:  Joseph D Berglund; Zorina S Galis
Journal:  Br J Pharmacol       Date:  2003-10       Impact factor: 8.739

2.  In vitro evaluation of sustained drug release from biodegradable elastomer.

Authors:  R Wada; S H Hyon; T Nakamura; Y Ikada
Journal:  Pharm Res       Date:  1991-10       Impact factor: 4.200

Review 3.  Quickening: Translational design of resorbable synthetic vascular grafts.

Authors:  Chelsea E T Stowell; Yadong Wang
Journal:  Biomaterials       Date:  2018-05-05       Impact factor: 12.479

4.  Mechanically tuned vascular graft demonstrates rapid endothelialization and integration into the porcine iliac artery wall.

Authors:  Kaspars Maleckis; Alexey Kamenskiy; Eliezer Z Lichter; Rebecca Oberley-Deegan; Yuris Dzenis; Jason MacTaggart
Journal:  Acta Biomater       Date:  2021-02-04       Impact factor: 8.947

Review 5.  Biomaterial-driven in situ cardiovascular tissue engineering-a multi-disciplinary perspective.

Authors:  Tamar B Wissing; Valentina Bonito; Carlijn V C Bouten; Anthal I P M Smits
Journal:  NPJ Regen Med       Date:  2017-06-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.